ATTENTION SURFACES CAN BECOME VERY HOT! ALWAYS USE PROTECTIVE GLOVES! During combustion, thermal energy is released that significantly increases the heat of surfaces, doors, handles, controls, glass, exhaust pipes, and even the front of the appliance. Avoid contact with those elements if not wearing protective clothing (protective gloves included).
SET FORTH IN THESE INSTRUCTIONS AND PROFESSIONAL STANDARDS, BY QUALIFIED PERSONNEL ACTING ON BEHALF OF COMPANIES CAPABLE OF ASSUMING FULL RESPONSIBILITY FOR THE ENTIRE SYSTEM. LA NORDICA S.p.A. IS NOT RESpONSIbLE fOR ANy uNAuThORISED mODIfICATIONS TO ThE pRODuCT, NOR fOR ThE uSE Of NON-ORIGINAL SpARE pARTS.
Page 5
undersTand The poTenTial hazards. children musT be supervised To ensure They do noT play wiTh The appliance. cleaning and mainTenance inTended To be performed by The user musT noT be carried ouT by children wiThouT supervision. do noT Touch The heaTer wiTh bare feeT or wiTh weT or damp body parTs. ...
fIRE SAfETy mINImum CLEARANCES Installation next to combustible or heat-sensitive materials is permitted, provided that suitable safety distances are maintained, as specified in the CEMI (CE Marking Information), the Declaration of Performance (DoP) and the label at the beginning of the manual (page 2).
figure 1 Beams Insulating refractory material Air vacuum Metallic protection IN CASE Of fAuLTS The steps to follow to safely switch off the appliance in the event of a malfunction are: Discontinue use of the product and contact the authorised Broken glass door service centre Immediately stop loading the firewood, do not open the door,...
Check the load-bearing capacity of the structure to ensure it can support the weight of the appliance. If the load-bearing capacity is insufficient, appropriate measures must be taken. LA NORDICA S.p.A.’s responsibility is limited to supplying the appliance only (see technical data in the document "CE MARKING INFORMATION").
Page 9
FOR PROPER OPERATION OF THE APPLIANCE, IT IS MANDATORY TO ENSURE AN ADEQUATE SUPPLY OF AIR IN THE INSTALLATION AREA, BOTH FOR COMBUSTION AND FOR RE-OXYGENATION OF THE ROOM. This means that, through dedicated openings communicating with the outside, combustion air must be able to circulate even when doors and windows are closed.
FLUE EXHAUST FLUE PIPE The componenTs of The combusTion gas evacuaTion sysTem musT be selecTed and raTed in accordance wiTh currenT regulaTions, considering The specific insTallaTion condiTions. The following checks are recommended: The chimney system must be assessed in accordance with the following technical standards (where applicable): en 15287-1, en 15287-2, en 13063-1, en 13063-2, en 1457, en 1806, en 1856-1, en 1856-2, and en 13384-1;...
Page 11
a cross-section that is too small will reduce the draught. a minimum height of 4 metres is recommended. The following materials are PROHIBITEd, as they compromise the proper functioning of the appliance: fibre cement, galvanised steel, rough or porous internal surfaces. illustrates several possible solutions.
CHIMNEY POT THE FLUE dRAUGHT ALSO dEPENdS ON THE SUITABILITY OF THE CHIMNEY POT. iT is Therefore essenTial ThaT, if The poT is cusTom-builT, The ouTleT cross-secTion be aT leasT Twice The inTernal cross-secTion of The flue ( Figure 5 since the chimney pot must always extend beyond the roof ridge, it must also ensure proper exhaust even in windy conditions Figure 6 The chimney pot must meet the following requirements:...
PERMITTED/NOT PERMITTED FUELS Only logs may be used as fuel. Only dry logs (max. moisture content 20%) should be used. A maximum of 2 or 3 logs should be loaded at a time. Logs should be approximately 20–30 cm in length and have a maximum circumference of 30–35 cm. NON-RESINOUS PRESSED WOOD LOGS MUST BE USED WITH CAUTION TO AVOID OVERHEATING THAT COULD DAMAGE THE APPLIANCE, AS THEY HAVE A HIGH HEATING VALUE.
INSTALLATION OF INSERT 100 WIDE.16 ASSEmbLy muST bE cARRIED OuT by quALIFIED pERSONNEL! The heaT venT graTe (Figure 8 pos. 6 - Figure 9) is To be insTalled on The upper parT oF The hood abouT 20 cm From The ceiling. This musT always be insTalled, as iTs FuncTion is To release The heaT accumulaTed inside The hood (overpressure) inTo The room.
Page 15
Figure 9 non-FireprooF maTerial FireprooF maTerial insulaTed Flue Images are for illustrative purposes ENGLISH...
FRESH AIR INTAKE For The appliance To FuncTion correcTly, a conTinuous airFlow musT be mainTained Through The designaTed opening aT The boTTom by removing The halF-cover - a . Figure 10 The halF-cover - a, should only be removed when insTalling The wind air venTilaTion kiT. Figure 10 iF The airFlow Through The hole in The boTTom oF The appliance is noT guaranTeed, The FronT panel musT be removed...
Page 17
Forced convecTion: By installing the OPTIONAL ventilation kit - WIND AIR KIT, it is possible to distribute hot air to adjacent rooms (see separate instructions). In order to promote the natural circulation of hot air, the half-covers must be removed from the bottom part of the outer casing of the product (Figure 11 - do noT remove The halF-covers...
Firebox door handle Ducted air outlet Primary air damper/Secondary air damper TeCHNICAl DesCRIpTIoN La NORDICA wood-fired products are suitable for heating living spaces for certain periods. LOgS ARe uSeD AS FueL. THIs Is AN INTeRmITTeNT CombusTIoN ApplIANCe. CoNsTRuCTIoN sYsTem: Type 1: products with automatic door closure.
Page 19
AIR FITTInG RInG VEnTILATIOn KIT ACCESSORIES POKER GLOVE WInD AIR (FIGuRE 10 - SuPPLIeD SuPPLIeD SuPPLIeD STANDARD OPTIONAL* STANDARD STANDARD * see CONNeCTION AND MAINTeNANCe OF OPTIONAL VeNTILATION instruction manual. uSInG A FLExIbLE hOSE (FIREPROOF, nOT SuPPLIED), COmbuSTIOn AIR CAn bE TAKEn DIRECTLy FROm OuTSIDE (SEE SECTIOn On VEnTILATIOn AnD AIRInG OF InSTALLATIOn ROOmS).
IGNITION at the first ignition, an unpleasant odour will inevitably be produced (due to the drying of the adhesives in the sealing gasket or the protective varnish), which disappears after a short period of use. however, good ventilation of the rooM Must be ensured. at the first ignition, it is advisable to liMit the aMount of loaded fuel, gradually increasing the heat output of the appliance.
Page 21
FIRST lOAD IGNITION (see figure A - For ignition, arrange the largest pieces of firewood (1) with a maximum length of 25 cm at the bottom; - Arrange the finer pieces of firewood (2), with a maximum length of 25 cm, on top of the other pieces (1);...
NORMAl OPERATION Before placing the firewood, fully open the primary air damper and, using the supplied poker, stir the embers to reignite them. Once the firewood is in the combustion chamber (see LOADING INSTRUCTIONS) close the door and wait up to 3 minutes for the flame to ignite, then set the damper in the appropriate position to obtain the nominal output.
NEVER OVERlOAD ThE APPlIANCE. TOO MUCh FUEl AND COMBUSTION AIR CAN CAUSE OVERhEATING AND ThUS DAMAGE ThE APPlIANCE. DAMAGE CAUSED BY OVERhEATING IS NOT COVERED BY WARRANTY. AlWAYS USE ThE PRODUCT WITh ThE DOOR ClOSED TO AVOID DAMAGE DUE TO OVERhEATING (FORGING EFFECT). IN ADDITION TO THE COMBUSTION AIR SETTING, THE COMBUSTION INTENSITY AND THUS THE HEAT OUTPUT IS ALSO INFLUENCED BY THE CHIMNEY.
CLEANING AND MAINTENANCE MUST ONLY BE PERFORMED WHEN THE APPLIANCE IS COLD. USE ONLY SPARE PARTS EXPRESSLY AUTHORISED AND SUPPLIED BY LA NORDICA S.P.A. PLEASE CONTACT YOUR SPECIALISED RETAILER IF YOU REqUIRE SPARE PARTS. NO CHANGES MUST BE MADE TO THE APPLIANCE!!! ClEANINg ThE glAss A specific secondary air inlet effectively slows down the formation of dirt deposits on the door glass.
ClEANINg ThE FIREbox gRATE IMPORTANT: If for any reason the grate is removed from the firebox, it is IMPORTANT, when replacing it, that the flat part with the narrower ash passages be facing upwards; failure to do so would make it difficult to remove the ash from the grate (see figure opposite ClEANINg ThE FluE Proper ignition, the right type and amount of fuel, the correct setting of the secondary air damper, a suitable chimney draught...
suMMER shuTDowN After cleaning the firebox, chimney and flue, ensuring that all ash and any other residue have been removed, all doors and relative firebox dampers should be closed. If the appliance is disconnected from the chimney, the outlet hole should be closed. IT IS ADVISAbLE TO CLEAN THE FLUE AT LEAST ONCE A YEAR;...
Symbol EN 16510-1 EN 16510-1 EXPLANATION Symbol Nominal heat output part Part load heat output CON / INT Appliance operation, Continuos (CON) or Intermittent (INT) / CO Carbon dioxide emission 2 nom 2 part / CO Carbon monoxide emission part Minimum distances to combustible materials - bottom Minimum distances to combustible materials - ceiling Minimum distances to combustible materials - floor in front...
Page 28
CONTACT YOUR DEALER OR CONSULT THE SITE WWW.LANORDICA-EXTRAFLAME.COM The manufacturer reserves the right to vary the characteristics and the data reported in this pamphlet at any moment and without notice, in order to improve its products. 06/03/2025 004300015-000 MAN.UT.INSERTO 100 WIDE.16...