Ecolab NALCO TRASAR 2 Manual
Ecolab NALCO TRASAR 2 Manual

Ecolab NALCO TRASAR 2 Manual

Pen fluorometer

Advertisement

NALCO COMPANY Locations
North America:
Headquarters
1601 West Diehl Road
Naperville, Illinois 60563
USA Energy Services Division
7705 Highway 90-A
Sugar Land, Texas 77487 • USA
Europe:
A-One Business Cente
Z.A. La Pièce 1
Route de l'Etraz • 1180-Rolle •
Switzerland
Asia Pacific:
2 International Business Park
#02-20
The Strategy Tower 2
Singapore 609930
Latin America:
Av. das Nações Unidas 17.891 • 6°
Andar 04795-100
São Paulo • SP • Brazil
www.nalco.com
3D TRASAR, TRASAR, Nalco and the
logo are Trademarks of Nalco Company.
Ecolab is a trademark of Ecolab USA, Inc.
©2012 Nalco Company
All Rights Reserved 4-12
Made in U.S.A.
OM-0255 – TRASAR 2 Pen Operation &
Maintenance Manual
RoHS
COMPLIANT
®
CAL
SELECT
READ/
ENTER

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NALCO TRASAR 2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ecolab NALCO TRASAR 2

  • Page 1 READ/ ENTER 3D TRASAR, TRASAR, Nalco and the logo are Trademarks of Nalco Company. Ecolab is a trademark of Ecolab USA, Inc. ©2012 Nalco Company All Rights Reserved 4-12 Made in U.S.A. OM-0255 – TRASAR 2 Pen Operation &...
  • Page 2 FLUOROMETER Principal uses for TRASAR 2 Pen fluorometer OVERVIEW include: Function Key • Cooling Towers Overview • Reverse Osmosis BATTERY • Process Applications COMPARTMENT ® • Waste Water MEAS Please call the Equipment Help Desk at 630 305 CHEM °C to reactivate or for technical support.
  • Page 3: Initial Set Up Procedure

    INITIAL SET UP • Press READ/ENT which will save the current value and increment PROCEDURE to the next digit Setting PF (Product factor) ® and % TRA Value (Background fluorescence SELECT value) READ/ ENTER STEP 1: Press 'SELECT' STEP 4: •...
  • Page 4: Calibration Steps

    CALIBRATION STEPS STEP 5: Press 'CAL' button – (Initiates a 2- STEP 1: Point calibration). ® Ensure you have Distilled water (DI water), TRASAR 2 Calibration SELECT Solution (Part#: 460-S0920.75), TRASAR 2 Pen fluorometer, plugs, syringe and filter READ/ ENTER before starting the calibration steps STEP 6:...
  • Page 5 STEP 9: STEP 13: Screen will blink “MEAS” several Press the 'READ/ENT' button within times (for about 7 seconds) and then less than 60 seconds. will read “Add Std”. MEAS seconds STEP 14: Screen will blink “MEAS” several STEP 10: times (for about 7 seconds).
  • Page 6: Measurement Steps

    MEASUREMENT STEPS to your syringe, before filling the sample cell. Due to compatibility NOTE: If your sample turbidity reasons, it is critical that you use range is greater than 20 NTU, only the filter sent in this package) please dilute or use a filter. The STEP 5: pen fluorometer does not check for turbidity.
  • Page 7 REACTIVATION Step 3: PROCEDURE Press 'SELECT' within 30 seconds (Unit will display To prevent competitors from using the reactivation the pen fluorometer to control their 30 seconds number. Write programs, a deactivation algorithm down the has been programmed into the reactivation device.
  • Page 8: Diagnostics And Troubleshooting

    Step 6: DIAGNOSTICS & TROUBLESHOOTING Enter the 4-digit password (Enter the Self-Diagnostic Messages numbers and Low battery indicator letters in the same manner as you The Battery indicator will indicate would enter the different levels of battery life. Use product factor.) fresh silver oxide batteries for replacement.
  • Page 9: Technical Specifications

    TECHNICAL SPECIFICATIONS: Measurement TRASAR Product Measuring Range 0-9999 ppm Resolution 0.1 ppm product Relative accuracy ±5 % of reading Calibration Two-point calibration – DI Water and calibration solution Temperature Measurement Range 5.0 to 50.0 °C (41.0 to 122.0 °F) Resolution 0.1 °C Temperature Compensation Automatic Temperature...
  • Page 10: Replacement/ Accessories

    REPLACEMENT/ ACCESSORIES: Product Description Part Number TRASAR 2 Pen Fluorometer 060-TSR2PENII.88 Silver Oxide battery Qty 1 (4 Batteries Required) 6017888 TRASAR 2 Calibration Solution (1L) 460-S0920.75 Cleaning Solution – 1:1 HCl (500ml) 460-S0726.74 Cleaning Solution – 10% Sulfuric Acid 460-S0800.74 (500ml) Distilled Water (500ml) 460-S0700.74...
  • Page 11: General Information

    GENERAL INFORMATION • 12-month coverage of all standard part-numbered Nalco Packaging / Scope of delivery equipment offerings (excepting consumable items and products The instrument is packaged in a with shelf lives of less than 12 plastic box with an instruction months.) manual.
  • Page 12 Tracer Technology. • Avoid exposure to extreme temperatures, excessive moisture, Nalco an Ecolab Company sand, or mechanical shock. Attn: Legal Department 1601 W. Diehl Road Naperville, IL 605 63...

This manual is also suitable for:

060-tsr2penll.88

Table of Contents