Page 1
English User’s Manual come with this product. Please download the other language’s User’s Manual version from this link (https://www.ya-man.co.jp/en/support/documents/) or scan with QR code with your camera phone. Please carefully read User’s Manual to ensure safe and proper use of the device.
Page 2
Steps for Use Set the Turn on Set vibration Select EMS Apply to scalp Turn off attachment the device on or off intensity level or skin the device Press and hold the Press the Press the LEVEL Use the device on a The device will Power/Vibration button Power/Vibration button...
Table of Contents p.31 Safety Precautions Additional Information p.12 p.31 Names and Functions of Components Checklist for Possible Problems p.15 p.33 Before Use Frequently Asked Questions p.20 p.35 How to Use Product Specifications p.28 p.36 After Treatment After-sales Service...
Safety Precautions Read these Safety Precautions carefully before using the device in order to use it correctly. Use the device sensibly in accordance with the prescribed steps. Immediately discontinue use and arrange to have the device repaired if any abnormality occurs. Do not use the device in a defective state, as doing so could cause a physical harm to the user.
Page 5
DANGER (Use and storage) The following individuals should not use the device: Failure to comply may cause malfunction of medical electronic device. Individuals using the following types of medical electronic devices: • pacemakers or other implanted electronic medical devices; Prohibition •...
Page 6
WARNING (Use and storage) Do not drop the device into water. Do not leave the Do not place the device in an unstable location. device in water. Do not drop or strike the device. Failure to comply may cause an electric shock, short Failure to comply may cause a malfunction of the Prohibition circuit or fire.
Page 7
WARNING (Use and storage) Always check for any signs of irritation on your scalp or skin during treatment. If irritation occurs or if the device does not agree your scalp or skin, stop using it immediately. Failure to comply may cause skin problems. If you are currently undergoing dental treatment Must Comply or have teeth fillings, choose a lower intensity...
Page 8
CAUTION (Use and storage) Those with sensitive scalps should monitor their condition during use and strictly follow the recommended usage guidelines. Excessive use may cause damage to the scalp. The following individuals should not use the device: The following individuals should not use the device: •...
Page 9
CAUTION (Use and storage) Do not use oils, scrubs, or other strongly stimulating products. Failure to comply may cause skin problems or malfunction of the device. Do not wipe the device with alkaline cleaners, alcohol, thinner, benzene, nail polish remover, or other solvents. Failure to comply may cause damage to the surface of the device.
Page 10
CAUTION (Use and storage) Discontinue use immediately if you feel fatigued or notice any abnormalities on your skin or scalp during use. If symptoms persist the following day and beyond, consult a physician. Always follow the recommended usage time. Use for up to 10 minutes per area per session, with a maximum total of 30 minutes per day.
Page 11
WARNING (The power supply) Do not cut, damage, modify, excessively bend, Always turn off the device and unplug the AC pull, twist, or bundle the AC adapter or USB adapter before cleaning. cable. Improper When not in use, always turn off the device and Do not place heavy objects on them or pinch them handling unplug the AC adapter.
Page 12
WARNING (The power supply) Do not use or leave the device near open flames, in direct sunlight, or in dusty areas. Do not throw the device into fire, heat it, or expose it to high temperatures. Do not charge, use, or store the device in hot environments.
Names and Functions of Components The design and specifications of the device and included accessories are subject to change for improvement purposes without notice. Accessories AC adapter Charging base (with USB cord)* User’s Manual Attachments (scalp/facial) *Do not use these accessories with any products other than Medi Lift Plus.
Page 14
Main unit Front view Back Electrode terminal LEVEL indicator / Battery charging indicator LEVEL button Power/Vibration button Charging terminals Mode indicator (SCALP/FACE)/ Vibration ON indicator...
Page 15
Functions Auto Power Off Micro-currents The device will automatically switch off approx. 10 minutes A gentle electrical current treats your scalp and skin. after it has been turned on. Vibration Delivers electrical stimulation to the muscles. Supports skincare by gently tapping your scalp and skin with gentle vibration.
Before Use Charge the Device Charging LEVEL indicator / Battery charging indicator flash When charging LEVEL indicator / Battery charging Household power outlet is complete indicator illuminate LEVEL indicator / Battery charging Charging Time Approx. 3 hours (room temperature approx. 25°C) indicator Operating time Approx.
How to remove and attach an attachment Switch between the scalp attachment or facial attachment according to the use. Scalp attachment: Exclusively for the scalp. Facial attachment: Can be used on your face, neck, or decollete. How to attach ...
Areas of use This product is a beauty device specifically for the scalp, face, neck, and decollete. *Do not use on areas other than scalp, face, neck, and decollete. Switching modes There are two modes: SCALP mode: Stimulates scalp muscles and stretches the entire scalp. Use the scalp attachment. FACE mode: Stimulates facial muscles for skin firming care.
Page 19
Pre-test for skin compatibility When using the device for the first time, always perform a skin compatibility test to help prevent irritation or other skin problems. Use the scalp attachment. Clean the skin Wash the inside of your arm with soap and water, then rinse and dry it thoroughly with a towel. Wet the inside of your arm with water, turn on vibration, set the device to SCALP Mode, and move it gently over the skin for approx.
Automatic Power-off This device will automatically turn off. The power will turn off automatically approx. 10 minutes after operation begins in any mode. Even if the intensity level is changed during treatment, the device will turn off approx. 10 minutes after the mode was first started. *If the mode is changed during treatment, the device will turn off approx.
How to Use Recommended Usage Use for up to 10 minutes per area per session, with a maximum total of 30 minutes per day. The device is suitable for daily use. If using the device on consecutive days, allow at least 24 hours between sessions. *These are general guidelines.
Page 22
Select an attachment and attach it to Wet the scalp or skin the main unit Scalp: Water, shampoo, hair treatment, or similar products The mode (SCALP mode/FACE mode) switches Skin: Water, lotion, gel, or similar products automatically. For attachment methods, refer to ‘How to remove and attach’...
Page 23
How to Use the Device in Each Mode SCALP mode (EMS + Photo (red LED) + Micro-current + Vibration ON/OFF option) Use the scalp attachment. We recommend that you use the device when the scalp is wet with water, etc., or while bathing with shampoo lathered throughout the hair. Press the Select your choice of Hold down the...
Page 24
Ensure that all brush pins and electrode pins contact the scalp, and move slowly along the arrows *Do not use on areas other than the scalp. Move the device in small zigzags around the frontalis muscle Move the device slowly from the hairline toward the and temporal muscle.
Page 25
When treatment is finished, press and hold the Power/Vibration button for approx. 1 second to turn off the power Points to note when using the device and how to place the device on the scalp Wetting the scalp first with water, shampoo, or hair treatment allows for smoother movement. We recommend using the device slowly, tracing from the hairline toward the crown.
Page 26
FACE mode (EMS + Photo (red LED) + Micro-current + Vibration ON/OFF option) Use the facial attachment. We recommend using the device in the bath or moistening your skin with water, lotion, or gel before using the device. Be sure to remove makeup before using the device. Press the Select your choice of Hold down the...
Page 27
Treating the neck and decollete Ensure that all soft electrode pins contact the face, and move slowly along the arrows *Use the device with continuous gliding motion. Areas you should not treat: Eyelids, around the eyes, *Always start at Level 1 when using the device for the Adam’s apple, collarbone first time.
Page 28
When treatment is finished, press and hold the Power/Vibration button for approx. 1 second to turn off the power...
After Treatment How to Clean (Main Unit) Clean the device after each use to maintain hygiene. Remove the attachment from the main unit. Rinse off any hair or dirt Make sure the device is Rinse the attachment under from the main unit turned off running water to remove any dirt...
Page 30
Wipe off any dirt from the surface of the device and moisture Dry the device in a location from the attachment using a towel or dry cloth that is well ventilated If stubborn dirt remains, gently wipe with a cloth dampened with diluted neutral detergent.
Storing the Device When not using the device for an extended period, clean it before storage. Be sure to wipe off any dirt from the main unit and electrode terminals before storage. When not in use, turn off the power and unplug the AC adapter from the wall power outlet before storing. Do not leave the device near fire or flame, under direct sunlight, or in hot and humid environments such as bathrooms.
The battery is low. Charge the battery (page 15). The device only operates The battery has expired. Inquiry the Global After Service (https://www.ya-man.co.jp/en/support/repair/) for a few minutes or your local distributor. even after charging *Do not try to replace the battery by yourself because this may cause a malfunction of the device.
Page 33
Symptom Possible causes and solutions EMS feels too strong Lower the EMS intensity with the Level button (page 17). (painful) Your skin is too dry. Moisturize your skin with water, lotion, gel, or similar products before using the device. The device does not ...
Frequently Asked Questions Rubbing strongly with the brush pins and electrode pins may cause scalp damage. Be sure to slide the device lightly over the scalp. Also, reapply moisture during My scalp becomes red treatment to ensure there is always moisture between the electrode pins and the scalp.
Page 35
Can I use the device To avoid skin problems, use on clean hair and scalp. with hair styling products? Yes, you may use shampoo, hair treatment, or hair lotion (excluding oil-based types) on the scalp, and facial lotion or gel on the face. Do not use oils, scrubs, or other strongly stimulating products.
Product Specifications Rated Power Supply DC5V 1.0A Maximum approx. 3 W (when charging) Power Consumption Battery Lithium-ion battery Charging Time Approx. 3 hours (Actual charging time may vary with conditions of the charging environment.) Operating time Approx. 30 minutes (from a fully charged state) (Operating time may vary with conditions of use and the EMS level.) Approx.
They can take this product for environmental safe recycling. Contacts for overseas customers For countries and regions outside Japan, please contact the store where you purchased your product for any inquiries. Alternatively, check the YA-MAN GLOBAL Official Website (https://www.ya-man.com/en/) Official website: https://www.ya-man.com/en/...
Need help?
Do you have a question about the myse and is the answer not in the manual?
Questions and answers