Ya-man Medi Lift PLUS User Manual

Ya-man Medi Lift PLUS User Manual

Wearable ems facial beauty device

Advertisement

User's Manual
Wearable EMS Facial Beauty Device
Medi Lift PLUS
EPM-18
Introduction
Thank you for purchasing this YA-MAN product.
Do not use the device before reading the Safety Precautions (pages 3-9).
Please read this User's Manual carefully for information on how to use the device properly and safely.
After reading the contents hereof, be sure to keep this User's Manual in an accessible location.
Make sure to include this User's Manual if you are transferring ownership of the device to another person.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Medi Lift PLUS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ya-man Medi Lift PLUS

  • Page 1 Introduction User’s Manual Thank you for purchasing this YA-MAN product. Do not use the device before reading the Safety Precautions (pages 3-9). Wearable EMS Facial Beauty Device Please read this User’s Manual carefully for information on how to use the device properly and safely.
  • Page 2 How to Use Apply Wear Turn on Select Turning off moisture gel on Medi Lift Plus the device EMS level the device the electrodes. Apply a drop of gel Wear the silicone mask Press down the left and Press the left and right...
  • Page 3: Table Of Contents

    Table of Contents Safety Precautions Additional Information Names and Functions of Components  Troubleshooting Before Use  Frequently Asked Questions How to Use  Product Specifications After Treatment After-sales Service...
  • Page 4: Safety Precautions

    Safety Precautions Read these Safety Precautions carefully before using the device. Use the device sensibly in accordance with the prescribed steps. Immediately discontinue use and arrange to have the device repaired if any abnormality occurs. Do not use the device in a defective state, as doing so could cause a physical harm to the user. The precautions listed in the User’s Manual are very important.
  • Page 5 DANGER (Use and storage) The following individuals should not use the device: Use of the device could cause electronic medical devices to malfunction.  Do not use the device in conjunction with any medical electronic equipment, including: Prohibited pacemakers or other implanted electronic medical devices; artificial heart-lung machines or other electronic life-support medical devices, or electrocardiographs or other worn electronic medical devices.
  • Page 6 WARNING (Use and storage) Do not use the device for any purpose other than Keep away from children and do not allow them those stated in the User’s Manual. to use the device. Non-intended Failure to comply may cause an injury or a failure of uses are Do not allow children or disabled persons to use the device.
  • Page 7 * Some products in the Medi Lift series can be used They may experience unpleasant sensations in their together with Medi Lift Plus. Please see the details in teeth due to the EMS stimulation. the User’ s Manual of the products you purchased.
  • Page 8 ATTENTION (Use and storage) If you feel an unpleasant tingling on your skin, reduce the EMS level (intensity). Failure to comply may cause a damage to your skin. Do not use the device continuously. Please allow intervals of at least 5 hours between treatments. The above information is a guideline only.
  • Page 9 WARNING (Power supply) Do not damage, modify, bundle, or otherwise Do not wet, wash or immerse the AC adapter or apply excessive force to the AC adapter or USB USB charging cable in water. charging cable. Exposure Failure to comply may cause an electric shock, short Do not place heavy objects on top of the AC to water Careless or...
  • Page 10 WARNING (The power supply) Do not leave the device in hot or humid places, Use with an operating voltage range from 100 V such as near flames, in bright sunlight or in a to 240 V. bathroom. Do not leave the device near Make sure the AC adapter and USB charging flammable gas or other such substances.
  • Page 11: Names And Functions Of Components

    Magnetic USB charging cable* User’s Manual  Silicone mask * Do not use these accessories with any products other than Medi Lift Plus. Controller (left/right) The illustration of the left controller describes each part.  Front view  Back view...
  • Page 12 Silicone mask  Front view Stopper Band [2] Stopper Band [1] A tongue of a lower jaw part of the mask  Back view Controller attachment parts Functions Auto Power Off The device will automatically switch off approx. 10 minutes after it has been turned on.
  • Page 13: Before Use

    Before Use Charge the device Charging The light will blink red. Controller (left) When charging The light will go off. Unplug is complete the USB charging cable. Light Charging time Approx. 2 hours (room temperature approx. 25° C) Light Operating time Approx.
  • Page 14 Pre-testing on Skin When using the device or a skin-care product for the first time, always test for compatibility with your skin to prevent skin problems. Wash the inner side of your upper arm with a soap, then wipe dry with a towel. Apply oil-free gel on washed skin and hold the controller on your upper arm.
  • Page 15: How To Use

    How to Use Preparation Attach the two controllers to the Prepare your skin and put your hair up silicone mask. if it is long. Check the left/right attachment guideline marks and push the After washing your face to remove makeup, please use your own controller into the recessed part on the back of the silicone mask.
  • Page 16 Wear Medi Lift Plus Turn the silicone mask inside out and Fit the silicone mask to your face. apply an appropriate amount of gel on each electrode (a total of 6 points on the right and left controllers). ❶ ❷...
  • Page 17 Pull stopper bands ❶ and ❷ diagonally Pull the tongue of a lower jaw part of the mask and adjust it so that the mask covers upwards, covering your ears, and fix the your entire face contour. mask firmly in place using the fastener. Point Fix the stopper bands in positions between the top of the head and the back of the head where they are held firmly in...
  • Page 18 Check that the silicone mask properly fits to your face on a mirror. In some cases, the silicone mask may not closely fit to your face and it may appear too loose. However, if the six electrodes on both the right and left controllers are all properly in contact with the skin, the device will be able to operate properly.
  • Page 19 Be sure the electrodes (a total of six on the right and left controllers) on the back of the silicone mask are in contact with your skin. If there is not enough contact between the electrodes and the skin, you may not benefit from the EMS effect. If you use an oil-based leave-in hair conditioner, only use the device when you have completely dry hair.
  • Page 20 How to apply treatment Turn on the device Select your choice of EMS level (intensity) Press down the +/ON button on both the right and left Press +/- button on the right and left controllers. controllers for over a second at the same time. Each time you press the +/- button, the device will beep and A beep will sound and the light will light up purple.
  • Page 21 Turning off the device The device will automatically switch off approx. 10 One long beep One long beep minutes after it has been turned on. Level To stop the treatment during use, press the -/OFF Weak Strong (No EMS output) (Max) button on the right or left controllers for over a second to turn off the device.
  • Page 22: After Treatment

    After Treatment How to clean the controllers To keep the product clean, please be sure to clean the controllers after each use. Remove the controllers from the silicone mask before cleaning. Wipe off any dirt using a well-wrung soft cloth or similar materials. For stubborn dirt, wipe gently with a cloth soaked in a diluted neutral detergent.
  • Page 23 How to clean the silicone mask Clean the silicone mask after each use. Remove the controllers from the silicone mask before cleaning. Wash the silicone mask Wipe off any moisture with Dry the silicone mask in a with warm water. a dry cloth such as a towel.
  • Page 24 Storage Store in a clean, well-ventilated place out of the reach of children. Remove the AC adapter and USB charging cable from the controller and the power outlet when not in use for a long period of time. Do not leave the device in hot or humid places, such as near flames, in bright sunlight or in a bathroom. Maintenance and Inspections If you have not used the device for an extended period, inspect it carefully and check that the device works properly and safely before use.
  • Page 25: Additional Information

    Additional Information Troubleshooting If you perceive any abnormality with the device during use, check to see if any of the following symptoms are present. Symptom Possible causes and solutions  Raise the EMS level with the + button (page 19). ...
  • Page 26 Symptom Possible causes and solutions The device does not  Press down the +/ON button for a second or longer (page 19). turn on.  The device has run out of power. Charge the battery (page 12).  The device will automatically switch off approx. 10 minutes after it has been turned on. The device only operates ...
  • Page 27: Frequently Asked Questions

    Frequently Asked Questions As a general guide, use the device up to 10 minutes at one time. * The device will automatically switch off approx. 10 minutes after it has been turned on. What is the recommended * The above information is a guideline only. Please observe your skin condition and use the device accordingly. duration and frequency of use? * Check carefully to make sure that there are no skin abnormalities before using the device.
  • Page 28 There is a difference in stimulation Most people have asymmetrical faces and may feel uneven stimulation on right between the right and left sides and left sides of their faces. Adjust the EMS level on the right and left controllers. of my face.
  • Page 29 Can I use Medi Lift Plus together Medi Lift Plus can be used together with Medi Lift Neck (EPN-10). If you wish to use with other devices in the...
  • Page 30: Product Specifications

    Product specifications Rated power supply DC5V 0.5A Power consumption Maximum approx. 1 W (when charging) Battery Lithium-ion battery Charging time Approx. 2 hours *May vary depending on the charging environment. Operating time Approx. 4.5 hours (when fully charged) *Operating time may vary with conditions of use and EMS level. Outside dimensions Silicone mask: approx.
  • Page 31: After-Sales Service

    Follow your local government rules for proper disposal of this product. This product uses a lithium-ion battery. Contacts for overseas customers For countries and regions outside Japan, please contact the store where you purchased your product for any inquiries. Alternatively, check the YA-MAN GLOBAL Official Website (https://www.ya-man.com/en/)