Introduction Thank you for purchasing a YA-MAN product. • Please read this User’s Manual carefully for information on how to use the device properly and safely. • After reading the contents hereof, be sure to keep this User’s Manual in an accessible location.
Page 3
Danger (regarding use and storage) ● The following individuals should not use the device. Use of the device could cause electronic medical devices to malfunction. ◆ Do not use in conjunction with any medical electronic equipment, including: Prohibition pacemakers or other implanted electronic medical devices; artificial heart-lung machines or other electronic life-support medical devices, and electrocardiographs or other worn electronic medical devices.
Page 4
WARNING (Use and storage) ● ● Do not overuse the device. Do not place heavy items on the device, drop the device For usage time and frequency, follow the instructions in the (especially during use), or otherwise subject the device User’s Manual.
Page 5
WARNING (Use and storage) ● Do not use or charge the device in the bathroom or near a bathtub, shower, sink, or other vessels filled with water. Failure to comply may cause an electric shock, short circuit, fire, or failure of the device. Exposure to water ●...
Page 6
WARNING (Use and storage) ● Do not leave the device near fire, in the hot sun, in a bathroom or other high-temperature/high-humidity location, or near combustible gas or a flammable object. Do not dispose of the device in a fire or place it near fire or flames. Do not use or charge in a high-temperature area or if the device is hot.
Page 7
ATTENTION (Use and storage) ● Do not wipe the device or charging base with alkali cleaning agent, alcohol, thinner, benzene, nail polish remover, or any other solvents. Failure to comply may cause damage to the surface of the device. Prohibition ●...
Page 8
ATTENTION (Use and storage) ● Reapply skin-care products or water during treatment to ensure that there is always some liquid between the electrode head and the skin. If there is an insufficient amount of skin-care products or water, the stimulation will weaken, causing skin problems. Mandatory ●...
Page 9
WARNING (The power supply) ● ● Do not damage, modify, bundle, or otherwise apply Do not wet, wash, or immerse the AC adapter or USB undue force to the AC adapter or USB charging cable. charging cable in water. Failure to comply may cause an electric shock, short circuit, fire, or Careless or Exposure to water Placing a heavy item on top of the AC adapter or USB charging cable,...
When Using Outside of Japan WARNING ● Use at AC100-240V only to avoid a potential fire or electrical shock hazard. Failure to comply may cause a fire, electric shock, or a failure of the device. Mandatory Compliance ● Be sure to check the plug configuration and the voltage of the power outlet before use. Failure to comply may cause the generation of heat, a fire, or a malfunction of the device.
Names and Functions of Components Main Body ● ● Front view Side view Electrode head Level indicator Level + button* Level - button* Hand Electrode Clean Mode button (Silver rim on the rear) Moist Mode button Cool Mode button * Press the +/- Level button to select Ion or EMS level.
Page 13
Accessories ● ● ● Charging base Cotton stopper USB charging cable (Attached to the electrode head of the main body (USB Type-C™)* before packaging) ● AC adapter ● User’s Manual Use this stopper to apply cotton to the electrode head (page 20). * For dedicated use with this product.
Before Use Charge the device Household power outlet Level indicator USB cable outlet Charging terminal AC adapter* * The form presented here is for illustration purposes only. Charging terminal Charging base USB charging cable Place the main body of the device on the charging base, which is connected to the USB charging cord, as shown in the diagram to begin charging. * If charging does not begin after approximately 10 seconds, check that the charging terminals of the main body and the charging base are aligned correctly (such that the USB cable outlet in the charging base is at the back of the main body), and that the USB charging cable or AC Adapter connection is not loose.
Page 15
ATTENTION • Do not overload an electrical circuit with the AC adapter. Be sure the AC adapter is inserted directly into the wall outlet. • Before charging, check that there is no liquid (water or gel, etc.) on the charging base. Liquid (water or gel, etc.) on the charging base during charging will cause the device to malfunction.
Page 16
Modes Mode Button display • Be sure to move the device on your skin while using it. (except when using the LED Lamps device in Cool Mode) • Use of cotton in Moist mode is optional. • The device and electrode head may get hot after using the Cool Mode. Do not Level indicator use Cool Mode continuous.
Page 17
Features Function Operating time Frequency Mode Button display Approximately five minutes • RF Helps beauty ingredients to (After two minutes and 30 seconds, • Ion Moisture penetrate into the stratum Treatments two to three times a beeping sound will notify you that (+ Vibration) per week corneum and moisturize...
Page 18
Timer A beeping sound will notify you half-way through the operating time. Refer to pages 15 and 16 for operating times in each mode. Standby Mode When treatment on a certain mode is completed, the device will emit a rapid beeping sound and switch to Standby Mode. (State in which functioning is suspended) Refer to pages 15 and 16 for operating times in each mode.
Page 19
Pre-testing on Skin When using the device for the first time, always test for compatibility. ● ATTENTION Be sure to perform a pre-test in order to prevent skin problems from occurring. ● If a rash, reddening, itchiness, stinging sensation, or other abnormality occurs at the pre-testing site, immediately stop the pre-test.
How to Use Precautions Read the items below carefully before use and use only as directed. ● Be sure to perform a pre-test before using the device for the first time (page 18). ● Be sure to move the device on your skin while using it. Using the device continuously on the same area may cause burns or other injuries. (except when using the device in Cool Mode) ●...
Page 21
Attaching Cotton to the Head Remove the cotton stopper from the electrode head. Place a piece of cotton on top of the electrode head and press the cotton stopper down over the cotton. • If the cotton stopper does not fit properly on the electrode head, please use a larger and thinner piece of cotton. Because thick cotton pads are difficult to fix in place, split them in half before use.
Page 22
Basic method of use Remove makeup and gently cleanse your Turn on the device face. Press down and hold the Mode button for the mode you wish to use (Clean, Moist, or Cool Mode button). (Hold down the button for approximately three seconds or •...
Page 23
(When using the device in Clean/Moist Mode only) Select your preferred Ion or EMS level (intensity). • Each time you press the Level + / - button, the device will beep and the ion/EMS level will change. • The Ion/EMS level can be adjusted between Level 1 and Level 5. When the setting reaches either Level 5 (maximum) or Level 1 (minimum), the device will emit a beeping sound.
Page 24
Hold the device so that your hand is Care for the skin when complete touching the Hand Electrode (the silver rim • When you have finished treatment, rub the remaining face lotion/gel into your skin before using your usual basic skin-care products to condition it. on the rear).
Page 25
How to use the device on your skin. Clean Mode • Recommended speed for moving the device: approximately four cm/second Move electrode head over the skin in the direction of the arrows shown below. * If the temperature feels too hot, move the head more quickly. The LED light can be used to treat areas around the eyes and the eyelids.
Page 26
Moist Mode Use the device for approximately two minutes and 30 seconds on each half of your face (for a total of approximately five minutes for your entire face). ● One side of your face (approximately two minutes and 30 seconds) Moisturizing waveform is being output for approximately one minute and 30 seconds, and muscle-training waveform is being output for approximately one minute.
Page 27
COOL Mode Press the electrode head repeatedly on your face as if stamping on the skin (Press → Release → Move electrode head). * The device can also be used around the eye area. * When using the LED light on the eyelids, be sure to close your eyes and keep the electrode head a minimum of five cm away from the skin.
After Treatment How To Clean Clean the device after each use for hygienic reasons. WARNING ● When cleaning the device, check to make sure it is not charging and that the power is switched off. To clean the device and electrode head, wipe it Wipe the entire main body of the device with a dry with a damp and well-wrung cloth to remove cloth and store it after removing all moisture.
Page 29
Storage ● If you will not be using it for an extended period, clean the device before storing it. ● When not in use, disconnect the AC adapter and USB charging cable from the wall power outlet, charging base, and the main body of the device. ●...
Additional Information Troubleshooting If you perceive any abnormality while using the device, verify the following points before arranging to have it repaired. Problem Possible Causes and Solutions Press the Mode button (Clean, Moist, or Cool Mode button) and hold for approximately three seconds or longer (page 21). The battery level is low.
Page 31
Problem Possible Causes and Solutions Lower the EMS intensity with the Level - button. The EMS feels strong The entire surface of the electrode head is not touching skin. Use a mirror to check that the entire surface of the electrode head is touching the skin. (unpleasant tingling, painful) Switch to a different area.
Frequently Asked Questions Recommended frequency of use: Two to three times a week for Clean/Moist Modes. The device can be used daily in Cool Mode. What is the recommended frequency Recommended duration of use: Clean Mode: three minutes; Moist Mode: five minutes; Cool Mode: three minutes and duration of use? Please do not use the device on the same mode more than once a day.
Product Specifications Power supply 5V/over 1.0 A Power consumption Approximately 4.5 W Battery Lithium ion battery Approximately three hours (Actual charging time will differ depending on the remaining battery level and the charging environment.) Charging time Approximately 40 minutes (when fully charged) Operating time (Operating time may vary depending on the operating mode, operating level, and/or operating environment.) Outside dimensions...
This product uses a lithium ion battery. Contacts for overseas customers For countries and regions outside Japan, please contact to the store where you have purchased your product for any inquiry about the product. Alternatively, check YA-MAN Global Official Website (https://www.ya-man.com/en/)
Page 35
Recommended cosmetics RF Booster Pad RF Booster Pad Flawless Serum Moisture Pore Refining Deep Cleansing Clear Deep Moisturizer Quantity: One box contains 15 sachets Quantity: One box contains 15 sachets Quantity: 80g/200g of one sheet type of one sheet type Item No.: CS19002/CS20001 (enough for approximately 1.5–2 months)
Need help?
Do you have a question about the HRF-40 and is the answer not in the manual?
Questions and answers