Advertisement

User's Manual
Home-care Beauty Device
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . 1
When Using Outside of Japan. . . . . . . . . . . 9
Before Use. . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
How to Use . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
English User's Manual come with this product.
Please download the other language's User's Manual version from this link
(https://www.ya-man.co.jp/en/support/documents/) or scan with QR code
with your camera phone.
Please carefully read User's Manual to ensure safe and proper use of the device.
Photo PLUS Shiny NEO
After Treatment . . . . . . . . . . . . . . . . . . . . . . 27
Additional Information . . . . . . . . . . . . . . . . 29
Troubleshooting . . . . . . . . . . . . . . . . . . . 29
Frequently Asked Questions . . . . . . . . . . 31
After-sales Service . . . . . . . . . . . . . . . . . . . . 33
YJFM18
TO ACCESS SCAN WITH
YOUR CAMERA PHONE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Photo PLUS Shiny NEO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ya-man Photo PLUS Shiny NEO

  • Page 1: Table Of Contents

    English User’s Manual come with this product. Please download the other language’s User’s Manual version from this link (https://www.ya-man.co.jp/en/support/documents/) or scan with QR code with your camera phone. Please carefully read User’s Manual to ensure safe and proper use of the device.
  • Page 2: Introduction

    Introduction Thank you for purchasing this YA-MAN product. • Please read this User’s Manual carefully for information on how to use the device properly and safely. • After reading the contents hereof, be sure to keep this User’s Manual in an accessible location.
  • Page 3 DANGER (Use and storage) ● The following individuals should not use the device: Failure to comply may cause electronic medical devices to malfunction.  Do not use the device in conjunction with any medical electronic equipment, including: Prohibited • pacemakers or other implanted electronic medical devices; •...
  • Page 4 WARNING (Use and storage) ● ● Do not use the device for a long time over areas where the Do not place heavy items on the device, drop the device skin is thin or areas above bones. (especially during use) or otherwise subject the device to a strong impact.
  • Page 5 WARNING (Use and storage) ● Do not use or charge the device in the bathroom or near a bathtub, shower, sink or other vessels filled with water. Failure to comply may cause an electric shock, short circuit, fire or failure of the device. Exposure ●...
  • Page 6 WARNING (Use and storage) ● Do not leave the device near fire, in the hot sun, in a bathroom or other high-temperature/high-humidity location or near combustible gas or a flammable object. Do not dispose of the device in a fire or place it near fire or flames. Do not use or charge in a high-temperature area or if the device is hot.
  • Page 7 CAUTION (Use and storage) ● Do not wipe the device or charging base with solvents such as alcohol, thinner, benzene, nail polish remover, kerosene, chemicals or polishing powder. Failure to comply may cause a damage to the surface of the device. Prohibited ●...
  • Page 8 CAUTION (Use and storage) ● Reapply skincare products or water during treatment to ensure that there is always some moistures between the electrode head and the skin. If there is an insufficient amount of skincare product or water, the stimulation will become weaker, causing skin problems. Mandatory ●...
  • Page 9 WARNING (Power supply) ● ● Do not damage, modify or bundle the USB charging cable. Do not wash or submerge the USB charging cable in water. Do not place heavy objects on the USB charging cable or allow it to get Exposure Careless or Failure to comply may cause an electric shock, short circuit, fire or failure...
  • Page 10: Table Of When Using Outside Of Japan

    When Using Outside of Japan WARNING ● Use only with a 5 V DC USB power supply. Failure to comply may cause a fire, electric shock or a failure of the device. Mandatory compliance ● Be sure to check the plug configuration and the voltage of the power outlet before use. Failure to comply may cause the generation of heat, a fire, or a malfunction of the device.
  • Page 11: Contents Names And Functions Of Components

    Names and Functions of Components Main Body ● ● Front view Back view LED Lamps Electrode head Mode lamp Mode button Hand Electrode Level indicator Power/Level button Remaining battery level indicator Charging terminal...
  • Page 12 Accessories ● ● ● Charging base Cotton stopper USB charging cable (attached to the electrode head of the main body when packaged) (USB Type-C™) ● User’s Manual Use this stopper to apply a cotton to the electrode head (page 19). * An exclusively item for this product.
  • Page 13 Functions Safety functions Equipped with a variety of sensors for safe use. Excessive care is prevented by controlling the output according to the condition of the device and your skin. ● Temperature sensor If the temperature of your skin or the treatment head becomes too high, the power will be turned off for safety (the device beeps 10 times). If this happens, let the device rest for about 30 minutes.
  • Page 14: Before Use

    Before Use Charge the device Using a household power outlet Household power outlet Remaining battery level indicator Charging terminal Charging terminal AC adapter* Charging terminal * Not included with the device. Charging base USB charging cable Using a computer Remaining battery level indicator Charging terminal Charging terminal Charging terminal...
  • Page 15 Charging The remaining battery level indicator flashes in white. When charging The remaining battery level indicator lights up in white for 5 seconds and then turns off. is complete Approx. 3 hours (at room temperature approx. 25°C). Charging time The actual charging time will differ depending on the remaining battery level, the charging environment, and the AC adapter (commercially available) being used. Approx.
  • Page 16 Pre-testing on skin When using the device for the first time, always test for its compatibility with your skin. ● CAUTION Be sure to perform a pre-test in order to prevent skin problems from occurring. ● If a rash, redness, itchiness, stinging sensation, or other abnormality occurs at the pre-testing area, immediately stop the pre-test.
  • Page 17: How To Use

    How to Use Precautions Read the items below carefully before use and use only as directed. ● Be sure to perform a pre-test before using the device for the first time (page 15). ● Be sure to move the device on your skin while it is in use. Using the device continuously on the same area may cause burns. (except in EYE CARE Mode and COOL Mode) ●...
  • Page 18 Modes Operating Recommended Mode Function Cotton pad Recommended cosmetics Level time frequency • RF Without a cotton Approx. • EMS Skin lotion or serum Every day 3 levels 3 minutes • Iontophoresis • LED (Red) • RF • Ion conduction Approx.
  • Page 19 Operating Recommended Mode Function Cotton pad Recommended cosmetics Level time frequency • Cool down Without a cotton Approx. Place directly on the skin – Every day 3 minutes • LED (Blue) *1: If using your regular skincare product, be sure it is water soluble. Do not use oil-based or scrubbing skincare products. Failure to comply may cause product malfunctions or skin problems.
  • Page 20 How to attach a cotton pad to the electrode head Remove the cotton stopper from the electrode head. Place a piece of cotton on top of the electrode head and press the cotton stopper down over the cotton. • If the cotton stopper does not fit properly on the electrode head, please use a larger and thinner piece of cotton. Because thick cotton pads are difficult to fix in place, split them in half before use.
  • Page 21 Basic method of use Remove makeup and gently cleanse your face. Turn on the device Hold down the Power/Level button (hold down the button for approx. 3 seconds • Remove oil and dirt from your skin so that it is in a clean condition prior or longer).
  • Page 22 Select the mode To change the mode, press and hold or briefly press the mode button. If Daily Care is selected, the mode button (DAILY) lights up. If Weekly Care is selected, the mode button (WEEKLY) and the mode lamp for the selected mode light up. (Daily Care) DAILY Mode...
  • Page 23 Select the treatment level (intensity) (except in COOL Mode) • Each time you briefly press the Power/Level button, the device will beep once and the level will change. Level 1 (the minimum) Level 2 Level 3 (the maximum) * The lamp on the outside of the button lights up in increments of 1/3. Power/Level button CAUTION •...
  • Page 24 Hold the device with your hand touching the Care for the skin after treatment hand electrode (the silver rim) on the rear • When you have finished treatment, rub the remaining lotion into your skin before using your usual basic skincare products to condition it. •...
  • Page 25 How to use the device on your skin DAILY Mode • Recommended speed for moving the device: approx. 2 cm per second * If the treatment temperature feels too hot, move the head more Move the electrode head over the skin in the direction of the arrows shown below. The LED light can be used to treat the upper eyelids, lower eyelids and outer quickly.
  • Page 26 CLEAN Mode DYHP Mode Move the electrode head over the skin in the direction of the arrows shown Move the electrode head over the skin in the direction of the arrows shown below. below. The LED light can be used to treat the upper eyelids, lower eyelids and outer corner of the eye.
  • Page 27 EYE CARE Mode COOL Mode Press the electrode head repeatedly on your face from the inner corner to the outer corner of Press the electrode head repeatedly on your face as if stamping on the the eye as if stamping on the skin (Press → Release → Move electrode head). skin (Press →...
  • Page 28: After Treatment

    After Treatment How To Clean Clean the device after each use for hygienic reasons. WARNING ● When cleaning the device, check to make sure it is not charging and that the power is switched off. To clean the device and electrode head, wipe Wipe the entire device with a dry cloth and store it them with a damp and well-wrung cloth to after removing all moisture.
  • Page 29 Storing ● If you will not be using it for an extended period, clean the device before storing it. ● Unplug the USB charging cable when not in use. ● Avoid storing the device near a heater or in a bathroom or other high-temperature/high-humidity location. Also, avoid unstable locations or places where there is exposure to direct sunlight.
  • Page 30: Additional Information

    Additional Information Troubleshooting If you perceive any abnormality while using the device, verify the following points before arranging to repair. Symptom Possible causes and solutions Press and hold the Power/Level button for approx. 3 seconds or longer (page 20). The device does not turn on The device has run out of power.
  • Page 31 Symptom Possible causes and solutions Raise the level by pressing the Power/Level button. The EMS feels weak The skin lacks moisture. Moisturize your skin with lotion before use. Also Moisturize your hand. (or you cannot feel it) You are not applying the device along muscles. Apply the electrode head along muscles (page 24). There is an insufficient charge.
  • Page 32: Frequently Asked Questions

    Frequently Asked Questions As a general guide, when using cotton pads, be sure the entire electrode head is moistened with skin lotion. How much of the skin lotion should I use each time? We recommend adding more skin lotion if you feel there is not enough. The recommended times are: [Daily Care] •...
  • Page 33: Product Specifications

    Product Specifications Rated input 5 V DC 1.0 A (Charging base) Rated output 9 V DC 0.55 A (Charging base) Power consumption Approx. 4.5 W (when charging) Battery Lithium-ion battery Approx. 3 hours Charging time * The actual charging time will differ depending on the remaining battery level, the charging environment, and the AC adapter (commercially available) being used.
  • Page 34: After-Sales Service

    After-sales service Rechargeable battery  This appliance contains batteries that are only replaceable by skilled persons.  The rechargeable battery is a consumable item (It is not covered by warranty).  The battery is expected to last 300 charge cycles. If the device no longer operates for more than a short period of time even after the battery has been recharged, the battery may have reached the end of its service life.
  • Page 35 Removing the battery Remove the screw cover and Remove the Remove the the rubber sheet with a thin, bottom housing back cover sharp object, then remove the screw. Screw Back cover Screw cover Screw Bottom cover Rubber sheet...
  • Page 36 Disconnect the battery cable Remove the battery Battery Battery cable ● CAUTION This image is intended to be used for disposing of the product, not repairing it. Do not disassemble the product except for disposal. Failure to comply may cause a fire, electric shock or other injuries.
  • Page 37 Contacts for overseas customers For countries and regions outside Japan, please contact the store where you purchased your product for any inquiries. Alternatively, check the YA-MAN GLOBAL Official Website (https://www.ya-man.com/en/) Official website: https://www.ya-man.com/en/...
  • Page 38 ©2023 YA-MAN LTD. ALL RIGHTS RESERVED. YJFM18-1-001E...

This manual is also suitable for:

Yjfm18

Table of Contents