*) Product specifications can be change without any notice.
WIRING DIAGRAM
Notes :
This Service Manual book was printed according to the latest data from manufacturing section.
This book can be owned but copying this book is prohibited without permission from IAQ Business Unit - FAN Department, PT Panasonic Manufacturing Indonesia.
Page 1
PMIEF2308002CE PMI/FAN/0908-04 Service Manual Ventilating Fan 40KAQA SPECIFICATION 40KAQA Model 220 V 50 Hz 230 V 50 Hz Volt/Hz 240 V 50 Hz Voltage 230 V 60 Hz Power Consumption Watt 47.0 52.0 67.0 59.0 Current 0.260 0.270 0.310 Ampere 0.290...
I. SAFETY INSTRUCTIONS Disconnect the power supply until blade is stationary before cleaning and maintenance. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Page 3
III. CAUTION Do not reconstruct this product. Otherwise, it may cause damage to the product or injury. The special-purpose or dedicated parts, such as mounting fixtures, must be used if such parts are provided. Otherwise, the product may fall down and it may cause injury. Components must be installed tightly.
Notice If all of three Motor Arm had to be unmounted from the Frame during the installation, the Motor Arm must be re-installed firmly to Frame and using the provided Rings. Do not kink or pinch the supply wiring. Otherwise, it may cause electric leakage, Electric shock or fire. Ceiling Minimum 50 mm Minimum 100 mm...
Clean the blades and other outer parts using warm water mixed with detergent, then wipe again with a dry cloth. Avoid using THINNER, GASOLINE, ALCOHOL, or materials that can cause rust or fade color. Don't let water reaches electrical parts like motor or switch. Use gloves during cleaning, to avoid accidents or injuries.
VII. PARTS NAME Size (mm): Main Frame 40KAQA Blade Motor Motor Cover Name Plate Supply Cord VIII. SERVICE STANDARD Type of Problem Possible Cause Repair Action The Motor not spinning T here is no electrical current Check the connection and electrical voltage...
Page 7
IX. ARRANGEMENT OF PARTS INSTALLATION 11 12 18 19 IMPORTANT NOTES FOR SAFETY : - Components / Parts which marked with are having special characteristic for safety. - Use original components / parts when replacing the product components / parts.
Page 8
X. SERVICE PART LIST Number Part Name Part Number Quantity (pcs) Shutter Set Plate 40AEAS961A Shutter Lever 25VGU1905 Shutter 40AAU0903ACG-E Balancer Plating 40AEA0951T Truss Tapp Screw TTS-D4X8LA Frame Assy 40AEAP900DPCG-E Blade Asembly 40AEAP800ACG-E Blade Set Screw 00HTN0101D 30AEA0290A Cushion Arm A 40AEAP910ACG-E Spring Washer SW-D8A...
XI. PACKING INSTRUCTION Top Pad 40KAU1407 Accesories 40KAU1413 Instruction Book 40KAQA461A Poly cover 00PPC0103 Bottom Pad B 40KAU1406 Bottom Pad A 40KAU1405 Packing Case (see table) Model No. Pos Code Label Packing Case Pos Code Label (see table) 40KAQANAHG 40KAQA410-NAHG 40KAQA22 40KAQA410-22 40KAQA400...
Need help?
Do you have a question about the 40KAQA and is the answer not in the manual?
Questions and answers