Connecting Poe Power Cables - H3C S9505 SRP Installation Manual

S9500 series routing switches
Table of Contents

Advertisement

Installation Manual
H3C S9500 Series Routing Switches
Figure 3-18 Install the PoE power entry module
3)
Fasten the screws on the top of the PoE entry module with a Philips
screwdriver.

3.8.3 Connecting PoE Power Cables

Note:
This section only focuses on the cable connection between the external
PoE power supply and the S9500 series switch. For the installation of the
external PoE power supply, see the manual accompanying the power
supply.
I. Grounding the PoE chassis
Follow these steps to ground the PoE chassis:
1)
Connect the wiring terminal (with one M6 hole) of the 6 AWG cable to
the grounding screw on the rear panel of the switch, as shown in
Figure
2)
Connect the other end of the cable to the grounding bar or other
grounding terminals.
3-19.
3-18
Chapter 3 Installing the Switch

Advertisement

Table of Contents
loading

This manual is also suitable for:

S9508 fabricS9512 fabric iiS9505S9508S9512S9508v

Table of Contents