Summary of Contents for Elettrotest HPS/P/200K

  • Page 1 HPS/P/200K USER MANUAL Clicca qui per vedere la versione in Italiano. 03/10/2024 62000591_02_.docx...
  • Page 2 CPS/M Models covered in this manual: Volt Range Model Code HPS/P/200kVA 99116963 150(Low) / 300(High) HPS/P 200KVA 175/350 VLN 9911696H 175(Low) / 350(High) ATTENTION: The information provided in this manual applies specifically to the HPS/P/200kVA model. For details regarding the HPS/P 200kVA 175/350 VLN model, please refer to Appendix "A”...
  • Page 3 Brochure Brochure for all the TPS-HPS-CPS models Describes all the machine modifiable TPS Parameters parameters and the start-up sequence. Parameters TPS protocol Describes how the Elettrotest remote Elettrotest Elettrotest communication protocol works. Protocol Describes how the SCPI remote TPS protocol...
  • Page 4 Documents Description Link QR-code PS Interface Software for remote use. PS_interface PSM Interface New software for remote use. PSM_Interface Manual and LabView Drivers for PS- Driver Driver LabView interface LabView 03/10/2024 62000591_02_.docx...
  • Page 5 HPS is a high-performance variable voltage generator (amplitude and frequency) in order to simulate and electrical line for test for different application (laboratory, test line, production line) Responsability: Elettrotest disclaims any responsibility for damage to people or things caused by an improper use of its products. Mandatory Verify voltage, power and frequency compatibility between HPS range and electrical specification of equipment under test (EUT).
  • Page 6: Safety Warnings

    • Do not make dielectric strengths test on the input or output of the equipment. Contact Elettrotest if you need to do specific test The manufacturer declines all responsibility for damage to people or things caused by an improper use of its products.
  • Page 7 DISPOSAL INFORMATION FOR USERS ON THE CORRECT HANDLING OF WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE) In reference to European Union directive 2012/19/EU issued on 24 July 2012 and the related national legislation, please note that: • WEEE cannot be disposed of as municipal waste and such waste must be collected and disposed of separately;...
  • Page 8: Table Of Contents

    INDEX INTRODUCTION .......................... 10 1.1. MAIN FEATURES ........................10 1.1.1. Output Voltage ......................10 1.1.2. Output frequency ......................10 1.1.3. User interface ....................... 10 1.1.4. General performances ....................11 1.1.5. General specifications ....................11 1.2. MODELS ..........................12 1.3. MAXIMUM OUTPUT CURRENT .................... 12 NOTES FOR USERS ........................
  • Page 9 EXISTENCE TABLE......................... 30 TECHNICAL SPECIFICATIONS ...................... 31 5.1. DATASHEET .......................... 31 5.2. MECHANICAL DRAWINGS ....................32 5.2.1. HPS/P/200K ........................32 5.3. DIAGRAM ..........................33 5.3.1. MAXIMUM OUTPUT VOLTAGE VS FREQUENCY ............33 5.3.2. INRUSH CURRENT VS TIME ..................33 5.4.
  • Page 10: Introduction

    1. INTRODUCTION HPS is a power source that supplies a sinusoidal and stable voltage. Its output voltage is adjustable in frequency and amplitude. 1.1. MAIN FEATURES 1.1.1. Output Voltage The output voltage is guaranteed perfectly sinusoidal, with a distortion of less than 0.6% regardless of the load.
  • Page 11: General Performances

    The user can set the output voltage through the numeric keyboard, or he can continuously vary the voltage through specific keys. The same possibility is valid for the setting of the frequency. The above possibility makes the HPS very flexible in those applications where it is requested a continuous variation of the two regulated magnitudes, around a given values.
  • Page 12: Models

    1.2. MODELS The following tables show all the characteristics of both types. MODELS NOMINAL SUPPLY WEIGHT INPUT INPUT DIMENSIONS A, L, P mm OUTPUT VOLTAGE CURRENT POWER POWER 400Vac ±10% HPS/P 200K 200KVA 1800 Kg 500A max 230KW 1800 : 1600 : 1000 1.3.
  • Page 13: Notes For Users

    2. NOTES FOR USERS 2.1. SWITCHING ON As soon as HPS switches on, through the switch placed on the control panel of the machine, it makes different cycles of test, indicated by the progression of the numbers from 0 to 9 on the displays. In case of bad working the test stops and the machine indicates on the control panel the type of alarm checked (see at the voice alarms).
  • Page 14: Range Setting

    progressively increases. If you want to set a fixed output voltage you can use the numeric keyboard located on the right of the control panel. To set the voltage proceed in the following way: • Push the button PROGRAM (the corresponding led switches on) •...
  • Page 15: Voltage Visualizzation

    2.5. VOLTAGE VISUALIZZATION The display concerning the output voltage can visualize four values: the set voltage or the output voltage for each phase. At turn on, the display visualizes the set voltage and this is indicated by the led on the button SET in the DISPLAY VOLT section of the panel. In order to visualize the actual output voltage, push the corresponding button (OUT);...
  • Page 16: Setting Frequency

    2.6.1. SETTING FREQUENCY The output frequency of HPS can changed between 50 and 80 hertz. To set the frequency proceed likewise the setting voltage through the buttons UP and DOWN (upwards and downwards arrow) and by means of the programming numeric keyboard. To set the frequency through the programming numeric keyboard you can proceed likewise the voltage pushing the button HERTZ instead of the button VOLT thus indicating to HPS that you want to program the frequency.
  • Page 17: Voltage Reaction

    2.7.1. VOLTAGE REACTION The stabilization of the output voltage coincides both on the HPS (2 wires) output terminals and on a possible long distance outlet (4 wires) to eliminate the fall in voltage influence of the connections. To operate the long distance stabilization first connect the opposite terminals on the back of the machine following the indications at the voice INSTALLATION.
  • Page 18: Supply Alarms

    2.8.1. SUPPLY ALARMS HPS can work with network voltage variations of 10%, if these limits are exceeded HPS stops and the led concerning the occurred alarm blinks, in this case HPS can be unblocked by means of the button HARDWARE RESET or switching off and switching on the machine. If the network voltage is too low HPS stops and the led UNDERVOLTAGE is lit.
  • Page 19: Change Configuration Master And Slave

    3. Close the contacts (1.7 and 1.8), when the machines are ON the change of the command master slave is disabled. 4. Set the mode of the machines (remote, range, sensing). You have to set only the master machines. 5. Enable the lines. 6.
  • Page 20: Installation

    3. INSTALLATION 3.1. GENERAL NOTES 3.1.1. POWER CABLING Take off the rear pannel • Connect a supply cable 3P+T of adequate size to support the current of the model. • Connect the load cable of correct size to support the maximum current (load 3-phase range 300/150). •...
  • Page 21: Signal Cabling

    3.1.2. SIGNAL CABLING This is an example of a three-machine configuration with one master and two slaves. SLAVE SLAVE MASTER 03/10/2024 62000591_02_.docx...
  • Page 22: Fuses

    3.2. FUSES Fuses can be used to protect power line of the HPS. It's recommended to use delayed fuses according to the nominal input characteristic (see section 5.1). 3.3. RCD PROTECTION A residual-current device (RCD), or residual-current circuit breaker (RCCB), is a device that instantly breaks an electric circuit to prevent serious harm from an ongoing electric shock.
  • Page 23: Wiring Diagram 2 Wire Configuration (Three-Phase Output)

    3.5.2. Wiring diagram 2 wire configuration (Three-Phase Output) Wiring configuration to follow for cabling one HPS/P 200KVA to a three-phase EUT without the sense wired (2-wires configuration). INPUT AUXILIARY MASTER SENSE 3PH OUTPUT 3PH AUXILIARY SLAVE Terminal N° 230Vac 230Vac 230Vac 230Vac 230Vac...
  • Page 24: Wiring Diagram 4-Wire Configuration (Three-Phase Output)

    3.5.3. Wiring diagram 4-wire configuration (Three-phase Output) Wiring configuration to follow for cabling one HPS/P 200KVA to a three-phase EUT with the sense wired (4-wires configuration). INPUT AUXILIARY MASTER SENSE 3PH OUTPUT 3PH AUXILIARY SLAVE Terminal N° 230Vac 230Vac 230Vac 230Vac 230Vac 230Vac...
  • Page 25: Wiring Diagram 2 Wire Configuration (Single-Phase Output)

    3.5.4. Wiring diagram 2 wire configuration (Single-Phase Output) Wiring configuration to follow for cabling one HPS/P 200KVA to a single-phase EUT without the sense wired (2-wires configuration). INPUT AUXILIARY MASTER SENSE 3PH OUTPUT 3PH AUXILIARY SLAVE Terminal N° 230Vac 230Vac 230Vac 230Vac 230Vac...
  • Page 26: Wiring Diagram 2 Wire Configuration (1Ph/3Ph Output)

    3.5.5. Wiring diagram 2 wire configuration (1PH/3PH Output) Wiring configuration to follow for cabling one HPS/P 200KVA to a three-phase EUT and to another single-phase EUT without the sense wired (2-wires configuration). INPUT AUXILIARY MASTER SENSE 3PH OUTPUT 3PH AUXILIARY SLAVE Terminal N°...
  • Page 27: Wiring Diagram 4 Wire Configuration (1Ph/3Ph Output)

    3.5.6. Wiring diagram 4 wire configuration (1PH/3PH Output) Wiring configuration to follow for cabling one HPS/P 200KVA to a three-phase EUT and to another single-phase EUT with the sense wired (4-wires configuration). INPUT AUXILIARY MASTER SENSE 3PH OUTPUT 3PH AUXILIARY SLAVE Terminal N°...
  • Page 28: Wiring Diagram Three Phase Of 2 Wire Configuration (Master/Slave)

    3.5.7. Wiring diagram three phase of 2 wire configuration (MASTER/SLAVE) Wiring configuration to follow for cabling two HPS/P 200KVA to two different lines (MASTER+MASTER configuration) or to one single line with 400kVA available (MASTER+SLAVE configuration). All without the sense. 03/10/2024 62000591_02_.docx...
  • Page 29 Relays Description: Relay Description CONFIGURATIONS AVAILABLE: QB15 Relay to switch HPS 1 ON/OFF. HPS1 HPS2 Line 1 Line 2 Relay to set the HPS 2 in master o slave QB16 configuration. Master Master 200KVA 200KVA QB17 Relay to switch HPS 2 ON/OFF. Master Slave 400KVA...
  • Page 30: Remote Control

    DB9 Poles Male    4.2. EXISTENCE TABLE Hereunder is shown the table of existence for the protocols and the hardware: MODELS Communication ports Protocols RS232 RS485 Elettrotest Elettrotest SCPI Modbus CPS/M CPS/T TPS/M TPS/T TPS/M/D XPS/M XPS/T X : Enabled...
  • Page 31: Technical Specifications

    5. TECHNICAL SPECIFICATIONS 5.1. DATASHEET MODEL 200K Power supply 3PH 400Vac ±10% Power 200KVA International Protection IP20 Pollution degree Overvoltage category Category II Maximum input current 500 Arms Input frequency 50Hz – 60Hz Input PF >0.82 Output type Three phases Output isolation isolated Maximum output...
  • Page 32: Mechanical Drawings

    5.2. MECHANICAL DRAWINGS 5.2.1. HPS/P/200K (*) All measure are on mm 1 – On/Off Switch 2 – Fans 3 – Grills 4 – Rear panel for connection 03/10/2024 62000591_02_.docx...
  • Page 33: Diagram

    5.3. DIAGRAM 5.3.1. MAXIMUM OUTPUT VOLTAGE VS FREQUENCY 5.3.2. INRUSH CURRENT VS TIME 3.50 3.00 2.50 2.00 1.50 1.00 0.50 0.00 10.0 20.0 30.0 40.0 50.0 60.0 Time (sec) 5.4. Internal fuses 03/10/2024 62000591_02_.docx...
  • Page 34: 99116963 Hps200K

    5.4.1. 99116963 HPS200K Name Description Size Current Type Voltage Breaking Capacity F1,F2,F3 Mainline Input fuse 630A 690V 100KA-120KA F4,F5,F6 Precharge fuse 10x38 500V F7,F8 Auxiliary line 400V 10x38 500V F9,F10 Auxiliary line 230V 5x20 250V F11, F12 Relay board 5x20 250V F13,F14 Control board...
  • Page 35: Service And Maintenance

    From 7 to 10 Years for general maintenance; You can check the HPS/P working hours both on the display and via remote. Please, note that it is necessary to return the machine to ELETTROTEST S.P.A for the scheduled maintenance. 6.2. ALARMS DIAGNOSIS AND REPAIRS If one or more alarms are shown, the user must not try to repair the HPS/P by himself.
  • Page 36: Basic Troubleshooting

    6.3. BASIC TROUBLESHOOTING Please, check these tables for problems that can be solve via basic operations. 6.3.1. Overvoltage / Undervoltage alarms Cause Solution Open the input connections and check the input Wrong input connections voltage, that needs to be (*)230V ±...
  • Page 37: Inverter Alarm

    6.3.3. Inverter Alarm Cause Solution Power module failure HPS/P must return to the supplier Power line Check the input voltage and all the fuses. 6.3.4. Max DV OUT alarm Cause Solution Low voltage setted If a very low voltage is set, DV OUT led is generally on. Check with the schematics the voltage inside the Wrong 2/4 wires configuration machine.
  • Page 38: Guarantee

    Such document must accompany the apparatus in case of periodic verification always. 8. REVISION INDEX Elettrotest Spa is committed to a program of continuous improvement of products and information to the customer. Therefore, the company reserves the right to make changes to the documentation and specifications without notice and assumes no responsibility for any incorrect information.
  • Page 39 THIS PAGE WAS INTENTIONALLY LEFT BLANK 03/10/2024 62000591_02_.docx...
  • Page 40: Appendix "A" - Hps/P/200Kva 175/350 Vln

    9. APPENDIX “A” - HPS/P/200KVA 175/350 VLN This chapter will illustrate all the electrical and construction differences between the “HPS/P/ 200KVA 175/350 VLN” model and the “HPS/P 200KVA” model described in the previous chapters. All the information reported in the previous paragraphs, except that specifically indicated in this chapter, is to be considered valid also for the “HPS/P/ 200KVA 175/350 VLN”...
  • Page 41: Maximum Output Currents

    9.3. MAXIMUM OUTPUT CURRENTS 99116963 HPS/P 200KVA 175/350 Configuration INRUSH INRUSH FOR 3 SEC COUNTINOUS LOAD COUNTINOUS Range Output Trifase 371.5 140.8 219.1 INDUCT. Trifase 347.5 115.3 194.6 RESIST. Trifase 325.5 94.4 172.8 CAPAC. Trifase 281.5 348.2 INDUCT. Trifase 695.2 230.5 389.2 RESIST.
  • Page 42: Manuale Utente

    HPS/P/200K MANUALE UTENTE Click here to see the English version. 03/10/2024 62000591_02_.docx...
  • Page 43 "A" di questo manuale. Questo manuale è scritto per le versioni firmware dalla TPSX 09_. Controlla sempre l’ultima versione del manuale al sito www.elettrotestspa.it Per consultare manuali di versioni precedenti, contatta il supporto Elettrotest: service@elettrotestspa.it 03/10/2024 62000591_02_.docx...
  • Page 44 Brochure Brochure for all the TPS-HPS-CPS models Describes all the machine modifiable TPS Parameters parameters and the start-up sequence. Parameters TPS protocol Describes how the Elettrotest remote Elettrotest Elettrotest communication protocol works. Protocol Describes how the SCPI remote TPS protocol...
  • Page 45 Documenti Descrizione Link QR-code Programma per l’utilizzo della macchina PS Interface PS_interface in remoto Manuale e Driver LabView per PS- Driver Driver LabView interface LabView 03/10/2024 62000591_02_.docx...
  • Page 46 HPS è un generatore di tensione variabile (ampiezza e frequenza) ad alte prestazioni per simulare e testare linee elettriche per diverse applicazioni (laboratorio, linea di test, linea di produzione). Responsabilità: Elettrotest declina ogni responsabilità per danni a persone o cose causati da un uso improprio dei propri prodotti. Obbligatorio: - Verificare la compatibilità...
  • Page 47 • Non effettuare test di rigidità dielettrica in uscita e/o in ingresso della macchina. Contattare Elettrotest in caso si debbano effettuare tali test. Il costruttore declina ogni responsabilità per danni a persone o cose derivanti da un utilizzo improprio dei suoi prodotti.
  • Page 48 SMALTIMENTO INFORMAZIONE AGLI UTENTI PER IL CORRETTO TRATTAMENTO DEI RIFIUTI DI APPARECCHIATURE ELETTRICHE ED ELETTRONICHE (RAEE) In riferimento alla Direttiva 2012/19/UE del Parlamento Europeo e del Consiglio del 24 luglio 2012 e alle relative normative nazionali di attuazione (D.Lgs. 49/2014), Vi informiamo che: •...
  • Page 49 INDICE INTRODUZIONE .......................... 10 1.1. PRINCIPALI CARATTERISTICHE ..................... 10 1.1.1. TENSIONE D’USCITA ..................... 10 1.1.2. FREQUENZA D’USCITA....................10 1.1.3. INTERFACCIA UTENTE ....................10 1.1.4. PRESTAZIONI GENERALI ....................11 1.1.5. SPECIFICHE GENERALI ....................11 1.2. MODELLI ..........................12 1.3. MASSIMA CORRENTE D’USCITA ..................12 NOTE DI UTILIZZAZIONE ......................
  • Page 50 CARATTERISTICHE TECNICHE ..................... 32 5.1. SCHEDA TECNICA ......................... 32 5.2. DISEGNI MECCANICI ......................33 5.2.1. HPS/P/200K ........................33 5.3. DIAGRAMMI ........................34 5.3.1. TENSIONE MASSIMA IN FUNZIONE DELLA FREQUENZA D’USCITA ......34 5.3.2. CORRENTE DI SPUNTO E TEMPO ................. 34 5.4.
  • Page 51: Introduzione

    1. INTRODUZIONE Il HPS e' una apparecchiatura che fornisce in uscita una tensione perfettamente sinusoidale e sta- bile, regolabile sia in frequenza, sia in ampiezza. L’HPS in pratica unisce i pregi della rete elettrica, del variac e del convertitore rotante senza averne i difetti! Una particolarità dell’HPS e' l'uscita isolata con uno speciale trasformatore di isolamento a potenza costante che consente di avere sempre la massima potenza di uscita a seconda dei vari utilizzi rimanendo sempre completamente isolati dalla rete!
  • Page 52: Prestazioni Generali

    sullo stato dell'uscita. Viene visualizzata sia la tensione impostata sia la frequenza impostata, inoltre é possibile la lettura della tensione di uscita con una precisione dello 0.3%. L'utente viene inoltre avvertito nel caso di superamento della corrente massima fornibile dall’HPS, oppure nel caso di caduta elevata nei collegamenti, che non deve superare il 10% della tensione impostata.
  • Page 53: Modelli

    1.2. MODELLI I modelli si differenziano per potenza e per il tipo di alimentazione POTENZA MODELLO ALIMENTAZ. PESO CORRENTE POTENZA DIMENSIONI D’USCITA RETE ASSORBITA D’INGRESSO A, L, P mm NOMINALE 400Vac ±10% HPS/P 200K 200KVA 1800 Kg 500A max 230KW 1800 : 1600 : 1000 HPS/P 400Vac ±10%...
  • Page 54: Note Di Utilizzazione

    2. NOTE DI UTILIZZAZIONE 2.1. ACCENSIONE All'atto dell'accensione, tramite l'interruttore presente sul frontale della macchina, l’HPS compie vari cicli di test, indicati dal progredire dei numeri da 0 a 9 sui display. Nel caso di malfunzionamento il test si ferma e la macchina indica sul frontale il tipo di allarme che si e' verificato (vedere la voce alarmi).
  • Page 55: Settaggio Tensione

    2.3.1. SETTAGGIO TENSIONE Per settare la tensione si può procedere in due modi: tramite gli appositi tasti UP e DOWN presenti a sinistra sul frontale, sia tramite il tastierino numerico di programmazione. I tasti UP e DOWN, indicati rispettivamente con una freccia verso l'alto e una verso il basso, consentono una variazione continua della tensione in uscita;...
  • Page 56: Visualizzazione Tensione

    2.5. VISUALIZZAZIONE TENSIONE Il display relativo alla tensione di uscita può visualizzare due grandezze: la tensione settata e la tensione in uscita. All'atto dell'accensione il display visualizza la tensione settata e ciò viene indicato dal led relativo al tasto SET relativo alla voce DISPLAY VOLT. Nel caso si voglia visualizzare la tensione effettiva in uscita basta premere il tasto relativo (OUT X);...
  • Page 57: Menu' Frequenza

    2.6. MENU’ FREQUENZA 2.6.1. SETTAGGIO FREQUENZA D’USCITA La frequenza in uscita dell’HPS può variare tra 50 e 80 hertz. Per settare la frequenza si procede analogamente al settaggio della tensione tramite i tasti UP e DOWN (freccia in su e freccia in giù) e tramite il tastierino numerico di programmazione. Per settare la frequenza tramite il tastierino numerico di programmazione si procede come per la tensione premendo al posto del tasto VOLT il tasto FREQ per indicare all’HPS che si vuole programmare la frequenza.
  • Page 58: Menu' Mode

    2.7. MENU’ MODE 2.7.1. REAZIONE DI TENSIONE La stabilizzazione della tensione in uscita può avvenire sia sui morsetti di uscita dell’HPS (2 WIRES) che su una eventuale presa a distanza (4WIRES ) per eliminare l'influenza della caduta di tensione dei collegamenti. Per operare la stabilizzazione a distanza bisogna prima collegare gli appositi morsetti presenti sul retro della macchina secondo le indicazioni riportate alla voce INSTALLAZIONE.
  • Page 59: Allarmi

    2.8. ALLARMI 2.8.1. ALLARMI DI ALIMENTAZIONE L’HPS può funzionare con variazioni della tensione di rete di 10%, nel caso vengano superati questi limiti l’HPS si blocca e lampeggia il led relativo all'allarme che si è verificato, in questo caso l’HPS può...
  • Page 60: Allarme Di Tensione

    2.8.4. ALLARME DI TENSIONE L’HPS, oltre al controllo della distorsione in uscita, opera un controllo del valore efficace della tensione in uscita sia nella configurazione 2WIRES che in quella 4WIRES. Nel caso la tensione in uscita non sia pari a quella impostata allora viene visualizzato un segnale di errore tramite il led MAX V alla voce VOLTAGE.
  • Page 61: Installazione

    Se si riscontrano danni, si prega di presentare immediatamente un reclamo al corriere. Non restituire il prodotto in fabbrica senza aver ottenuto la preventiva accettazione dell'Autorizzazione al Reso Merce (RMA) da parte di ELETTROTEST S.P.A. 3.1.2. CABLAGGIO DI POTENZA Rimuovi il pannello di uscita •...
  • Page 62 AUX MASTER SENSE OUT 3-FASE AUX SLAVE INGRESSO SENSE AUX MASTER OUT 3-PHASE AUX SLAVE INPUT 12 13 14 15 16 17 18 19 20 L1 L2 L3 N L1 L2 L3 N PE L1 L2 L3 PE 03/10/2024 62000591_02_.docx...
  • Page 63: Cablaggio Dei Segnali

    3.1.3. CABLAGGIO DEI SEGNALI Questo è un esempio del cablaggio delle parti di segnale tra tre HPS 200KV/P, due configurati come slave ed uno come master. MASTER SLAVE SLAVE 03/10/2024 62000591_02_.docx...
  • Page 64: Fusibili

    3.2. FUSIBILI Per la protezione della linea di alimentazione dell’HPS è possibile utilizzare dei fusibili. Si consiglia l’uso di fusibili ritardati adeguati alle caratteristiche nominali della macchina (vedere paragrafo 5.1). 3.3. PROTEZIONI DIFFERENZIALI La protezione differenziale protegge in caso di guasto verso terra (dispersione elettrica) e quindi protegge dal rischio di folgorazione.
  • Page 65: Schema Di Cablaggio Per Un Hps/200/P In Configurazione 2 Fili (Output Trifase)

    3.5.2. SCHEMA DI CABLAGGIO PER UN HPS/200/P IN CONFIGURAZIONE 2 FILI (OUTPUT TRIFASE) Configurazione di cablaggio da seguire per il cablaggio di un HPS/P 200KVA ad un EUT trifase senza il sense cablato (configurazione a 2 fili). INPUT AUXILIARY MASTER SENSE 3PH OUTPUT 3PH AUXILIARY SLAVE...
  • Page 66: Schema Di Cablaggio Per Un Hps/200/P In Configurazione 4 Fili (Output Trifase)

    3.5.3. SCHEMA DI CABLAGGIO PER UN HPS/200/P IN CONFIGURAZIONE 4 FILI (OUTPUT TRIFASE) Configurazione di cablaggio da seguire per il cablaggio di un HPS/P 200KVA a un EUT trifase con il sense cablato (configurazione a 4 fili). INPUT AUXILIARY MASTER SENSE 3PH OUTPUT 3PH AUXILIARY SLAVE...
  • Page 67: Schema Di Cablaggio Per Un Hps/200/P In Configurazione 2 Fili (Output Monofase)

    3.5.1. SCHEMA DI CABLAGGIO PER UN HPS/200/P IN CONFIGURAZIONE 2 FILI (OUTPUT MONOFASE) Configurazione di cablaggio da seguire per il cablaggio di un HPS/P 200KVA ad un EUT monofase senza il sense cablato (configurazione a 2 fili). INPUT AUXILIARY MASTER SENSE 3PH OUTPUT 3PH AUXILIARY SLAVE...
  • Page 68: Schema Di Cablaggio Per Un Hps/200/P In Configurazione 2 Fili (Output Mono/Trifase)

    3.5.2. SCHEMA DI CABLAGGIO PER UN HPS/200/P IN CONFIGURAZIONE 2 FILI (OUTPUT MONO/TRIFASE) Configurazione di cablaggio da seguire per il cablaggio di un HPS/P 200KVA ad un EUT trifase ed ad un altro EUT monofase senza il sense cablato (configurazione a 2 fili). INPUT AUXILIARY MASTER SENSE 3PH...
  • Page 69: Schema Di Cablaggio Per Un Hps/200/P In Configurazione 4 Fili (Output Mono/Trifase)

    3.5.3. SCHEMA DI CABLAGGIO PER UN HPS/200/P IN CONFIGURAZIONE 4 FILI (OUTPUT MONO/TRIFASE) Configurazione di cablaggio da seguire per il cablaggio di un HPS/P 200KVA ad un EUT trifase ed ad un altro EUT monofase con il sense cablato (configurazione a 4 fili). INPUT AUXILIARY MASTER SENSE 3PH...
  • Page 70: Configurazione Di Cablaggio Per Due Hps/200/P (Master/Slave)

    3.5.4. CONFIGURAZIONE DI CABLAGGIO PER DUE HPS/200/P (MASTER/SLAVE) Configurazione di cablaggio da seguire per il cablaggio di due HPS/P 200KVA su due linee diverse (configurazione MASTER+MASTER) o su un'unica linea con 400kVA disponibili (configurazione MASTER+SLAVE). Tutto senza sense cablato (configurazione 2 fili). 03/10/2024 62000591_02_.docx...
  • Page 71 Descrizione relè: Relè Descrizione QB15 Relè per Accendere/Spegnere l’HPS 1. Relè per impostare l’HPS2 in modalità master QB16 o slave. CONFIGURAZIONI DISPONIBILI: QB17 Relè per Accendere/Spegnere l’HPS 2. Relè per selezionare la modalità di uscita del HPS1 HPS2 Linea 1 Linea 2 QB20 sistema (modalità...
  • Page 72: Controllo Remoto

     4.2. TABELLA DI ESISTENZA HARDWARE E PROTOCOLLI La tabella di esistenza tra hardware, porte di comuncazione e protocolli utilizzabili è mostrata qui sotto. Modelli Porte di Comunicazione Protocolli RS232 RS485 Elettrotest Elettrotest SCPI Modbus CPS/M CPS/T TPS/M TPS/T TPS/M/D...
  • Page 73: Caratteristiche Tecniche

    5. CARATTERISTICHE TECNICHE 5.1. SCHEDA TECNICA MODELLO 200K Alimentazione 3PH 400Vac ±10% Potenza nominale 200KVA Grado di protezione IP20 Inquinamento ambientale Immunità contro le Categoria II sovratensioni Massima corrente di 500 Arms ingresso PF ingresso >0.82 Frequenza di ingresso 50Hz – 60Hz Tipo di uscita Trifase Isolamento uscita...
  • Page 74: Disegni Meccanici

    5.2. DISEGNI MECCANICI 5.2.1. HPS/P/200K (*) Tutte le misure sono in millimetri 1 – Interruttore accensione 2 – Ventilatore 3 – Griglie 4 – Pannello connessioni 03/10/2024 62000591_02_.docx...
  • Page 75: Diagrammi

    5.3. DIAGRAMMI 5.3.1. TENSIONE MASSIMA IN FUNZIONE DELLA FREQUENZA D’USCITA 5.3.2. CORRENTE DI SPUNTO E TEMPO 3.50 3.00 2.50 2.00 1.50 1.00 0.50 0.00 10.0 20.0 30.0 40.0 50.0 60.0 Time (sec) 03/10/2024 62000591_02_.docx...
  • Page 76: Fusibili Interni

    5.4. Fusibili interni 5.4.1. 99116963 HPS200K Nome Descrizione Dimensione Corrente Tipo Tensione Capacità di apertura F1,F2,F3 Fusibili d’ingresso 630A 690V 100KA-120KA F4,F5,F6 Fusibili precarica 10x38 500V F7,F8 Linea ausiliaria 400V 10x38 500V F9,F10 Linea ausiliaria 230V 5x20 250V F11, F12 Scheda relè...
  • Page 77: Manutenzione E Service

    • Da 7 a 10 anni per la manutenzione generale; Le ore di funzionamento del tuo HPS/Ppossono essere controllate via remoto oppure nel display all’accensione della macchina. Si ricorda che è necessario restituire la macchina a ELETTROTEST S.P.A per la manutenzione programmata. 6.2.
  • Page 78: Risoluzione Problemi Base

    6.3. RISOLUZIONE PROBLEMI BASE Controlla le tabelle mostrate qui sotto per risolvere alcuni problemi tramite delle semplice operazioni. 6.3.1. ALLARMI DI SOVRATENSIONE Cause Solution Aprire i collegamenti di ingresso e verificare la tensione, che deve essere (*)230V ± 10% per Connessioni di ingresso errate macchine monofase e (*)400V ±...
  • Page 79: Allarme Max Dv Out

    Limitazione della corrente di uscita Controllare la tensione e la corrente di uscita. La macchina è fuori calibrazione. Si prega di Calibrazione contattare il service ELETTROTEST. 6.3.5. ALLARME LIMIT IOUT Cause Solution Controllare la tensione e la corrente di uscita, Sovraccarico rimuovere l'EUT e verificarne il comportamento.
  • Page 80: Garanzia

    8. REVISIONE Elettrotest Spa è impegnata in un programma di miglioramento continuo dei prodotti e delle informazioni verso il cliente. Si riserva quindi di apportare modifiche alla documentazione e alle specifiche senza preavviso, declinando ogni responsabilità...
  • Page 81 QUESTA PAGINA È LASCIATA INTENZIONALMENTE VUOTA 03/10/2024 62000591_02_.docx...
  • Page 82: Appendice "A" - Hps/P/200Kva 175/350 Vln

    9. APPENDICE “A” - HPS/P/200KVA 175/350 VLN Questo capitolo elencherà tutte le differenze elettriche e costruttive tra il modello “HPS/P/ 200KVA 175/350 VLN” ed il modello “HPS/P 200KVA“ descritto nei capitoli precedenti. Tutte le informazioni riportate nei paragrafi precedenti, tranne quelle indicate specificatamente in questo capitolo, sono da ritenersi valide anche per il modello “HPS/P/ 200KVA 175/350 VLN”...
  • Page 83: Massima Corrente D'uscita

    9.3. MASSIMA CORRENTE D’USCITA 99116963 HPS/P 200KVA 175/350 Configurazione INRUSH INRUSH PER 3 SEC CONTINUA CARICO COUNTINUA Range Uscita Trifase 371.5 140.8 219.1 INDUT. Trifase 347.5 115.3 194.6 RESIST. Trifase 325.5 94.4 172.8 CAPAC. Trifase 281.5 348.2 INDUT. Trifase 695.2 230.5 389.2 RESIST.