Page 1
INSTALLATION GUIDE SEALED PELLET STOVE MIDA AIR 6 S2 5S MIDA AIR 6 XUP! S2 5S MIDA AIR 8 S2 5S MIDA AIR 8 XUP! S2 5S PART 1 - REGULATIONS AND ASSEMBLY Translation of original instructions...
No part of this manual may be translated into other languages, adapted and/or reproduced, even in part, in other mechanical and/or electronic form or media, for photocopies, recordings or other, without the prior written authorisation of MCZ Group Spa. The company reserves the right to make changes to the product at any time without prior notice. The owner company reserves its rights according to law.
1-WARNINGS AND WARRANTY CONDITIONS SAFETY WARNINGS • Before commencing any operation, the user and anyone preparing to work on the product must have read and understood the important warnings in the installation guide. This will guarantee safe use of the product, as well as optimising the environmental benefits resulting from use of this heat generator.
Page 5
1-WARNINGS AND WARRANTY CONDITIONS • Packaging items are NOT toys, as they can cause risk of suffocation or strangling and other health hazards! People (including children) with reduced mental or motor capacities, or lacking experience and knowledge, must be kept away from the packaging.
Page 6
1-WARNINGS AND WARRANTY CONDITIONS • In products with ducted hot air, the outlet air temperature can become very hot, even around 150°C: therefore any ducting must be insulated with adequate materials in crossings in contact with flammable surfaces or that are affected by the temperature (e.g.
Page 7
1-WARNINGS AND WARRANTY CONDITIONS • In the event of fire in the chimney, turn off the device, disconnect it from the mains and do not open the door whatsoever. Then contact the competent authorities. • With the exception of sealed installations (certified sealed product and outside ducting of combustion air + connection to chimney made hermetically with respect to the installation environment), it is also forbidden for liquid fuel appliances with continuous or intermittent operation that draw the combustion...
Page 8
1-WARNINGS AND WARRANTY CONDITIONS • Live electrical parts: only power the product once it has been fully assembled. • Disconnect the product from the 230V power supply before performing any maintenance operations. The plug must be removed in such a way that an operator can verify from any point to which he/she has access, that the plug remains unplugged.
1-WARNINGS AND WARRANTY CONDITIONS INFORMATION: • Please contact the retailer or qualified personnel for any information, problem or malfunction. • Only use the fuel specified by the manufacturer. • When the product is switched on for the first time, it is normal for it to emit smoke due to the paint heating up for the first time. Therefore make sure the room it is installed in is well-ventilated.
Page 10
1-WARNINGS AND WARRANTY CONDITIONS WARRANTY CONDITIONS For the duration, terms, conditions, limitations of the MCZ conventional warranty, please refer to the specific warranty card that is included with the product. Information for management of waste electrical and electronic equipment containing batteries and accumulators This symbol appears on the product, on the batteries, on the accumulators or on their packaging or on their documentation;...
1-WARNINGS AND WARRANTY CONDITIONS WARNINGS FOR THE CORRECT DISPOSAL OF THE PRODUCT The owner is the sole party responsible for demolishing and disposing of the stove, which must be performed in compliance with laws related to safety and environmental protection in force in his/her country. At the end of its working life, the product must not be disposed of as urban waste.
Page 12
1-WARNINGS AND WARRANTY CONDITIONS LEGENDA WHERE TO DISPOSE MATERIALS Metal Glass If there is any, to be disposed of separately based on the material used: Tiles or ceramics OUTER CLADDING Stone Glass ceramic (fire door): to be disposed of with inert or mixed waste If there is any, to be disposed of separately based on the material used: Tempered glass (oven door): to be disposed...
Page 13
The EC Declaration of Conformity, the Declaration of Performance required by EU Regulation 305/2011 and all other product certification documents can be downloaded by scanning the QR code on this page (also found on the product label) or by accessing the website page www.mczgroup.com/support/mcz Having specified the above, we highlight and report that: •...
2-INSTALLATION The instructions in this chapter refer explicitly to the Italian installation regulation UNI 10683. In any case, always observe the regulations in force in the country of installation. PELLETS The pellet is obtained from natural dried wood sawdust (without paint). The compactness of the material is guaranteed by the lignin contained in the wood itself, without glue or binders.
Page 15
2-INSTALLATION FOREWORD The heating system (generator + combustion air supply + combustion product expulsion system + any hydraulic/aeraulic system) must be installed in compliance with the laws and regulations in force , and carried out by a qualified technician, who must issue a declaration of conformity of the system to the system manager and shall undertake full responsibility for final installation and consequent good operation of the product.
2-INSTALLATION MINIMUM DISTANCES Observe the distances to flammable walls/objects (sofas, furniture, wood panelling, matchboarding, etc.) as specified in the technical data table with reference to the diagram below. If objects considered to be particularly sensitive to heat are present, such as furniture, curtains or sofas, as a precaution, increase the stove clearances substantially to avoid possible deterioration due to the effect of heat.
Page 17
2-INSTALLATION In any case, ensure adequate distance to facilitate access during cleaning and extraordinary maintenance. If this is not possible, it must still be possible to distance the product from adjacent walls/elements. This operation must be performed by a technician qualified to disconnect the combustion product expulsion ducts and their subsequent restoration.
Page 18
2-INSTALLATION Below 15kW: Air duct diameter Maximum length Maximum length (smooth duct) (corrugated duct) 50mm 60mm 80mm 100mm Above 15kW: Air duct diameter Maximum length Maximum length (smooth duct) (corrugated duct) 50mm 60mm 80mm 100mm...
Page 19
2-INSTALLATION Preparing the smoke expulsion system The combustion product expulsion system is a particularly important element for the proper operation of the appliance and must be correctly sized according to EN 13384-1. Its creation/adaptation/verification must always be carried out by a legally qualified operator and must comply with the regulations in force in the country where the appliance is installed.
Page 20
2-INSTALLATION Chimneypot The chimneypot, meaning the end part of the flue, must meet the following characteristics: • the smoke outlet section must be at least double the internal section of the chimney; • prevent the penetration of rain or snow; •...
2-INSTALLATION EXAMPLES OF INSTALLATION (DIAMETERS AND LENGTHS TO BE SIZED) 1. Flue installation with hole for the passage of the pipe increased by: • minimum 100mm around the pipe if next to non-flammable parts such as cement, brick, etc.; or •...
3-DRAWINGS AND TECHNICAL SPECIFICATIONS DRAWINGS AND CHARACTERISTICS MIDA AIR 6/8 S2 5S STOVE DIMENSIONS Ø57 Ø80...
Page 23
3-DRAWINGS AND TECHNICAL SPECIFICATIONS MIDA 6/8 XUP! S2 5S STOVE DIMENSIONS Ø80 Technical Dept. - All rights reserved - Reproduction prohibited...
Page 24
3-DRAWINGS AND TECHNICAL SPECIFICATIONS MIDA AIR 6 S2 5S/ MIDA AIR 6 XUP! S2 5S Brand EU Standard EN 16510-1:2022 / EN 16510-2- 6:2022 (ex-EN 14785) Appliance Type (tightness) Type CC50 Continuous (CON) or intermittent (INT) operation CON / INT...
Page 25
3-DRAWINGS AND TECHNICAL SPECIFICATIONS Partial load heat input Pinputpart Partial load heat output Ppart Fuel consumption at partial load heat output kg/hpart 0,64 kg/h Pellet tank autonomy at partial load heat output* Autpart Efficiency at part load heat output ηpart CO2 at partial load heat output CO2part CO (%) at 13% O2 at partial load heat output...
Page 26
3-DRAWINGS AND TECHNICAL SPECIFICATIONS Electrical consumption at nominal heat output elmax Electrical consumption at part load heat output elmin Maximum electric power input Wmax Electrical consumption at standby elSB Power supply voltage Power supply frequency Pellet tank volume Tankvol Pellet tank capacity* Tankkg Height/Width/Depth of the appliance H/W/L...
Page 27
3-DRAWINGS AND TECHNICAL SPECIFICATIONS MIDA AIR 8 S2 5S/ MIDA AIR 8 XUP! S2 5S Brand EU Standard EN 16510-1:2022 / EN 16510-2- 6:2022 (ex-EN 14785) Appliance Type (tightness) Type CC50 Continuous (CON) or intermittent (INT) operation CON / INT Fuel type Wood Pellet (L) Fuel dimensions...
Page 28
3-DRAWINGS AND TECHNICAL SPECIFICATIONS Partial load heat input Pinputpart Partial load heat output Ppart Fuel consumption at partial load heat output kg/hpart 0,64 kg/h Pellet tank autonomy at partial load heat output* Autpart Efficiency at part load heat output ηpart CO2 at partial load heat output CO2part CO (%) at 13% O2 at partial load heat output...
Page 29
3-DRAWINGS AND TECHNICAL SPECIFICATIONS Electrical consumption at nominal heat output elmax Electrical consumption at part load heat output elmin Maximum electric power input Wmax Electrical consumption at standby elSB Power supply voltage Power supply frequency Pellet tank volume Tankvol Pellet tank capacity* Tankkg Height/Width/Depth of the appliance H/W/L...
Page 30
ACCORDING TO COMMISSION REGULATIONS (EU) 2015/1185 - (EU) 2015/1186 (PRODUCT FICHE) Manufacturer: MCZ GROUP SpA Trademak: Model Identifier: MIDA AIR 6 S2 5S / MIDA AIR 6 XUP! S2 5S Indirect heating functionality: Direct heat output (space heat output): Indirect heat output (water heat output): CPR harmonised standard:...
Page 31
3-DRAWINGS AND TECHNICAL SPECIFICATIONS INFORMATION REQUIREMENTS FOR SOLID FUEL LOCAL SPACE HEATERS ACCORDING TO COMMISSION REGULATIONS (EU) 2015/1185 - (EU) 2015/1186 (PRODUCT FICHE) MCZ GROUP SpA Manufacturer: Trademak: Model Identifier: MIDA AIR 8 XUP! S2 5S Indirect heating functionality: Direct heat output (space heat output):...
Page 32
3-DRAWINGS AND TECHNICAL SPECIFICATIONS INFORMATION REQUIREMENTS FOR SOLID FUEL LOCAL SPACE HEATERS ACCORDING TO COMMISSION REGULATIONS (EU) 2015/1185 - (EU) 2015/1186 (PRODUCT FICHE) Manufacturer: MCZ GROUP SpA Trademak: Model Identifier: MIDA AIR 8 S2 5S Indirect heating functionality: Direct heat output (space heat output):...
4-UNPACKING INSTRUCTIONS FOR PACKAGING DISPOSAL The material that the appliance’s packaging is made of must be managed correctly, in order to make collection, reuse, recovery and recycling easier, where possible. The table below illustrates the possible components that the packaging is made of, and the relative instructions for correct disposal. DESCRIPTION CODE MATERIAL SYMBOL...
Page 34
4-UNPACKING Handle the product with suitable means paying attention to the applicable safety regulations in force. Do not turn the packaging over and handle the majolica parts with care. The stove is delivered in a single package. Open the package, remove the two screws “v” which secure the stove brackets to the pallet and then remove the bracket “S”...
Page 35
4-UNPACKING Therefore, the end user is responsible for product storage, disposal or possible recycling in compliance with the relative applicable laws in force. Do not store the stove unit or its cladding without their packaging. Position the stove and connect it to the flue. Remove the plastic tie that fastens the top to the structure of the stove. If the stove needs to be connected to an outlet pipe which goes through the rear wall (to connect to the flue), take utmost care to make sure that the joint is not forced.
5- SMOKE OUTLET REAR SMOKE OUTLET TOP SMOKE OUTLET The stove with the top outlet can have a MONO or COAX type of installation (see the FIRST IGNITION chapter). In the MONO type of installation, the single wall smoke outlet pipe is inserted directly with the “T” cap fitted. In the COAX type of installation, the double wall pipe is inserted by removing the “T”...
Page 37
5- SMOKE OUTLET INSTALLATION OF CONCENTRIC SMOKE OUTLET WITH SEPARATE COMBUSTION AIR The stove is designed to be connected to the flue through a concentric pipe (XUP version), by means of a special pre-installed fitting. If, due to different requirements, there is a need to draw the combustion air directly from an external wall, the air pipe can be separated from the concentric fitting.
Page 38
5- SMOKE OUTLET • remove pipe “h” (combustion air) from the concentric fitting by unscrewing metal clamp “o” • detach and remove air inlet box “k” with pipe “h” by simply pulling it firmly • remove pipe “h” and air inlet box “k” •...
6-INSTALLATION AND ASSEMBLY Live electrical parts: only power the product once it has been fully assembled. On delivery, the stove has no metal cladding, as shown in the image below. Take the box with the package (figure below) and prepare the material for installation. REAR VERSION HIGHER VERSION METAL CLADDING...
6-INSTALLATION AND ASSEMBLY REMOVING THE TOP To remove the complete top “D”/”E”, proceed as follows: • Lift the cover “E” • Remove the two screws “k” • Lift the complete top “D”/”E” and put it away in a safe place until the next use REAR VERSION HIGHER VERSION...
Page 41
6-INSTALLATION AND ASSEMBLY ASSEMBLING LOWER FRONT CLADDING Before assembling the chosen side cladding, mount the lower panel “A” as follows: • Take the lower panel “A”, the 4 screws “x” and 2 washers “y” from the box • Secure the panel “A” to the structure of the stove using the 4 screws “x” and 2 washers “y” Technical Dept.
Page 42
6-INSTALLATION AND ASSEMBLY ASSEMBLING UPPER FRONT CLADDING Before assembling the chosen side cladding, mount the lower panel “B” as follows: • Take the upper panel “B”, the 4 screws “x” and 2 washers “y” from the box • Secure the panel “B” to the structure of the stove using the 4 screws “x” and 2 washer s“y”...
Page 43
6-INSTALLATION AND ASSEMBLY ASSEMBLING THE SIDE CLADDING To install the side cladding, proceed as follows: • take a panel “C” (there is no right or left as they are symmetrical) • for installation, the panel “C” must be placed with the engraved arrow pointing towards the front of the stove (towards the door) Technical Dept.
Page 44
6-INSTALLATION AND ASSEMBLY • Take metal side “C” and insert the holes “v” in the hooks “z” on the stove frame.
Page 45
6-INSTALLATION AND ASSEMBLY • fasten the panel “C” at the top with the two screws “x”. Place the M5 notched washer “y” between the screw “x” and the panel. Technical Dept. - All rights reserved - Reproduction prohibited...
Page 46
6-INSTALLATION AND ASSEMBLY • repeat the same procedure with the other panel “C”...
6-INSTALLATION AND ASSEMBLY ASSEMBLING THE TOP Once the decorative sides “C” have been fitted, the top “D” can be set back into place. • take the top “D”/”E” with the previously removed screws “k” (see “REMOVING THE TOP” on the previous pages) •...
Page 48
6-INSTALLATION AND ASSEMBLY ACCESS TO THE ELECTRONIC BOARD The circuit board “J” is on the right side (handle side). If you need to access the board, you must remove the back side panel as explained above. ACCESS TO THE GEARMOTOR To access the gear motor the side panel must be removed.
7-OPENING THE DOORS OPENING THE DOOR OF THE FIREBOX To open the firebox door”R”, fit the cold handle “V” into its hole in the handle, and pull it outwards. Attention! The firebox door must be closed properly for the stove to work correctly. Only open the doors when the stove is switched off and cold.
8-CONNECTION TO ADDITIONAL DEVICES INSTALLATION OF WIFI PANEL (OPTIONAL-CODE 4020003) Use the knockout hole at the back of the stove to install the Easy Connect WiFi panel and follow the installation instructions found inside the product. The WiFi panel must be connected to the board on the stove using the supplied cable. In order to use the WiFi system, download the Easy Connect app and follow the set-up instructions.
9-LOADING THE PELLETS LOADING THE PELLETS Fuel is loaded from the upper part of the stove by lifting the door “E”/“F” . Pour the pellets in slowly so that they are deposited at the bottom of the hopper. Caution! Keep the pellet cover “E” open ONLY as long as necessary to pour the pellets into the stove, and make sure that the plastic bag does not touch the hot parts of the stove.
10-ELECTRICAL CONNECTION ELECTRICAL CONNECTION First connect the power cable to the back of the stove and then to a wall socket. It is recommended to disconnect the power cable when the stove is not used. ELECTRICAL STOVE CONNECTION The cable must never come into contact with the smoke exhaust pipe or any other part of the stove. STOVE POWER SUPPLY Connect the power cable to the back of the stove and then to a wall socket.
Page 56
MCZ GROUP S.p.A. Via La Croce n°8 33074 Vigonovo di Fontanafredda (PN) – ITALY Telephone: 0434/599599 a.s. Fax: 0434/599598 Internet: www.mcz.it e-mail: mcz@mcz.it 8902423101 REV 0 19/02/2025...
Need help?
Do you have a question about the MIDA AIR 6 XUP! S2 5S and is the answer not in the manual?
Questions and answers