White Balance Adjust (White Balance Adjustments); Remote Select (Tally/Remote-Terminal Settings) - JVC BM-H1310SU - Color Production Monitor Instructions Manual

Color video monitor
Table of Contents

Advertisement

SET-UP FOR MONITOR INSTALLATION (continued)

WHITE BALANCE ADJUST (white balance adjustments)

Before making these adjustments, select the color
temperature 9300K or 6500K on MENU.
Adjustment (level)
RED DRIVE (-10,-9...0...+9, +10)
GREEN DRIVE (-10,-9...0...+9, +10)
BLUE DRIVE (-10,-9...0...+9, +10)
RED CUTOFF (-10,-9...0...+9, +10)
GREEN CUTOFF (-10,-9...0...+9, +10) Sets the cut-off voltage of a green signal component.
BLUE CUTOFF (-10,-9...0...+9, +10)

REMOTE SELECT (TALLY/REMOTE-terminal settings)

Via the TALLY/REMOTE terminal, the tally lamp can be
turned on/off, or a function (selected from display 3 3 3 3 3 shown
on the right) can be operated using an external control.
INPUT setting indications and selected inputs
Setting
NOT USE AÔB AÔY/C AÔRGB AÔCOMPO BÔY/C BÔRGB BÔCOMPO Y/CÔRGB Y/CÔCOMPO RGBÔCOMPO
Indication
A
Short-circuit
Open-circuit
B
CNTL-1/CNTL-2 setting indications and set positions
Setting Indication
NOT USE UNDER SCAN PULSE CROSS COLOR OFF BLUE CHECK EXTERNAL SYNC ASPECT RATIO COLOR TEMP. AUDIO MUTE
Short-circuit
ON
OFF
Open-circuit
[TALLY/REMOTE terminal functions
All controls via TALLY/REMOTE terminal are made by short-circuiting or open-circuiting
any pin from Pin 1 to 4 and either Pin 7 or 8 (GND each) of this terminal.
When using this terminal, be sure to short-circuit Pin 5 and either Pin 7 or 8.
To open-circuit
CNTL-1
To
short-circuit
To open-circuit
INPUT
To
short-circuit
Adjusts the drive level of a red signal component.
Adjusts the drive level of a green signal component.
Adjusts the drive level of a blue signal component.
Sets the cut-off voltage of a red signal component.
Sets the cut-off voltage of a blue signal component.
: indicates when deactivating the remote control via the TALLY/REMOTE terminal
A
A
A
Y/C
RGB
COMPO.
: indicates when deactivating the remote control via the TALLY/REMOTE terminal
ON
ON
OFF
OFF
GND
1
Tally lamp
6
7
To turn off
8
To turn on
1
3
5
4
2
To open-circuit
Function
B
B
B
Y/C
RGB
COMPO.
ON
External
OFF
Internal
TALLY
CNTL-2
To short-circuit
NOTE
By making white balance
adjustments on SET-UP MENU,
appears to the right of the COLOR
TEMP. setting on MENU
(see page 11).
REMOTE SELECT
q
I NPUT
: A B
CNT L - 1
: UNDER SCAN
CNT L - 2
: ASPECT RAT I O
:
ENTER
3 3 3 3 3
Y/C
Y/C
RGB
RGB
COMPO.
COMPO.
16-9
6500
4-3
9300
NOTE
When the TALLY/REMOTE terminal
is used, the following functions
become deactivated (except when
they are set to "NOT USE"):
- Front INPUT SELECT and EXT
SYNC switches
- Front UNDER SCAN, PULSE
CROSS, COLOR OFF and BLUE
CHECK switches
- On-screen MENU's ASPECT RATIO
and COLOR TEMP. functions
- Remote MUTE key
If a function is applied to both CNTL-1
and CNTL-2, CNTL-1 has priority.
1:
Pin 6 is DC power output pin. It
outputs DC 5 V when the monitor's
power is on. (Do not short-circuit pin 6
directly to ground.)
r
ON
OFF
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bm-h1900su

Table of Contents