STAR Water Systems 3CDH Instructions Manual

Pedestal sump pump

Advertisement

Available languages

Available languages

Quick Links

ATTACH YOUR RECEIPT HERE
Purchase Date
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 1-800-742-5044, 7:30 a.m. - 5:00 p.m., EST, Monday - Friday.
PEDESTAL SUMP PUMP
1
© 2025. All rights reserved.
MODELS #3CDH, 5CDH
Español p. 11
025472 B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3CDH and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for STAR Water Systems 3CDH

  • Page 1 PEDESTAL SUMP PUMP MODELS #3CDH, 5CDH Español p. 11 ATTACH YOUR RECEIPT HERE Purchase Date Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-742-5044, 7:30 a.m. - 5:00 p.m., EST, Monday - Friday.
  • Page 2: Package Contents

    PACKAGE CONTENTS DESCRIPTION QUANTITY Pump Float Rod Stops Pump Float Rod Float Float Rod Guide Float Rod Guide Float Rod Guide Screw Float Rod Guide Float Stops Screw PUMP DIMENSIONS LENGTH Width 10-IN Height 32.25-IN Float Float Rod Cord length 10-FT SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the...
  • Page 3 WARNING • ELECTRICAL SHOCK ALERT Before installing this product, have the electrical circuit checked by an electrician to ensure proper grounding. All electrical installations must conform to the National Electric Code and all local codes. • ELECTRICAL SHOCK ALERT Connect this product to a properly-grounded 115 volt circuit equipped with a Ground Fault Circuit Interrupter (GFCI) device.
  • Page 4: Specifications

    PHASE VOLTS AMPS AMPS SIZE 0 FT. 5 FT. 10 FT. 15 FT. 20 FT. 3CDH 1-1/2 5CDH 16.6 1-1/2 NOTES: Do and Do NOT for sump pumps: DO NOT use this pump for anything other than sump pump pit installations.
  • Page 5 ASSEMBLY INSTRUCTIONS 1. Attach the float rod guide to the pump column, about 6 in. below the motor. Clamp the guide to the column with the included screw. DO NOT OVERTIGHTEN. Float Rod Guide Screw Float Rod Guide Column 2. Screw float onto the threaded end of the float rod.
  • Page 6 4. Slide the first rubber float rod stop down the float rod to about 8-in from the top of the float rod. Approximately 8 in. 1st Float stop Float rod 5. Slide the float rod through the hole in the pump switch.
  • Page 7: Installation Instructions

    INSTALLATION INSTRUCTIONS 1. Make sure the sump basin is cleared of any debris or sediment, and place pump on a hard surface inside the basin. NOTE: Make sure there is enough room in the basin for the float to move freely. If the float is restricted, the pump will not operate.
  • Page 8: Care And Maintenance

    INSTALLATION INSTRUCTIONS 4. Test the operation of the pump by pouring water into the sump basin. 5. If the lower rod stop is positioned 8 in. from Top Float Rod Stop IL2045 the top of the rod, the pump will turn on at approximately 10 in.
  • Page 9: Replacement Parts List

    REPLACEMENT PARTS LIST For replacement parts, call our customer service department at 1-800-742-5044, 7:30 a.m. - 5:00 p.m., EST, Monday - Friday. DESCRIPTION PART # Replacement switch 024773 WARRANTY This product is warranted for one year from the date of purchase. Subject to the conditions hereinafter set forth, the manufacturer will repair or replace to the original consumer, any portion of the product which proves defective due to defective materials or workmanship.
  • Page 10: Troubleshooting

    TROUBLESHOOTING DANGER RISK OF ELECTRIC SHOCK. Always disconnect power source before attempting to install, service or maintain the pump. Never handle a pump with wet hands or when standing on wet or damp surface or in water. Fatal electrical shock could occur. PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION...
  • Page 11 BOMBA DE SUMIDERO DE PEDESTAL MODELOS #3CDH, 5CDH ADJUNTE SU RECIBO AQUÍ Fecha de compra ¿Preguntas, problemas, partes faltantes? Antes de acudir al minorista, llame a nuestro departamento de servicio al cliente al 1-800-584-8089, de lunes a viernes de 7:30 a.m. a 5:00 p.m., EST.
  • Page 12: Información De Seguridad

    CONTENIDO DEL PAQUETE DESCRIPCIÓN CANTIDAD Bomba Float Rod Stops Pump Varilla del flotador Flotador Float Rod Guide Guía de la varilla del flotador Float Rod Guide Tornillo de la guía de la Screw varilla del flotador Topes del flotador DIMENSIONES DE LARGURA Float LA BOMBA...
  • Page 13 ADVERTENCIA • ALERTA DE DESCARGA ELÉCTRICA. Antes de instalar este producto, haga que un electricista revise su circuito para asegurarse de que la puesta a tierra sea adecuada. Todas las instalaciones eléctricas deben cumplir con el Código Nacional de Electricidad (NEC, por sus siglas en inglés) y con todos los códigos locales. •...
  • Page 14: Especificaciones

    DESCARGA ARRANQUE PIES PIES PIES PIES PIES 3CDH 1-1/2 pulg. 5CDH 16.6 1-1/2 pulg. NOTAS: Antes de instalar la bomba: NO use esta bomba para instalaciones que no sean de pozo para bomba de NO use un cable de extensión con una bomba de sumidero.
  • Page 15: Instrucciones De Ensamblaje

    INSTRUCCIONES DE ENSAMBLAJE 1. Fije la guía de la varilla del fl otador a la columna de la bomba, aproximadamente a 15.2 cm (6 pulg.) debajo del motor. Sujete la guía a la columna con el tornillo incluido. NO APRIETE DEMASIADO. Tornillo del a guía de la varilla del flotante La guía de la varilla...
  • Page 16 4. Deslice el primer tope de goma de la varilla del fl otador hacia abajo hasta aproximadamente 20.3 cm (8 pulg.) de la parte superior de la Aproximadamente varilla del fl otador. 20 centímetros (8 pulgadas) Primer tope de varilla de caucho Varilla de flotador 5.
  • Page 17: Instrucciones De Instalación

    INSTRUCCIONES DE INSTALACIÓN 1. Asegúrese de que el recipiente del sumidero esté libre de suciedad y sedimentos y luego coloque la bomba de sumidero sobre una superfi cie dura dentro del recipiente. NOTA: Asegúrese de que haya el espacio sufi ciente en el recipiente para que el fl otador se mueva libremente.
  • Page 18: Cuidado Y Mantenimiento

    INSTRUCCIONES DE INSTALACIÓN 4. Para probar el funcionamiento de la bomba, vierta agua en el recipiente del sumidero. 5. Si el tope de la varilla inferior se coloca a 20,32 Tope superior de la IL2045 cm de la parte superior de la varilla, la bomba varilla del flotador se encenderá...
  • Page 19: Piezas De Repuesto

    PIEZAS DE REPUESTO Para obtener piezas de repuesto, llame a nuestro departamento de servicio al cliente al 1-800-742-5044, de lunes a viernes de 7:30 a.m. a 5:00 p.m., Hora del Este. DESCRIPCIÓN PIEZA NO. Interruptor de repuesto 024773 GARANTÍA Este producto se garantiza por un período de un año a partir de la fecha de compra. Sujeto a las condiciones establecidas en el presente, el fabricante reparará...
  • Page 20: Solución De Problemas

    SOLUCIÓN DE PROBLEMAS PELIGRO RIESGO DE DESCARGA ELÉCTRICA. Desconecte siempre la fuente de alimentación antes de intentar instalar, reparar o realizarle mantenimiento a la bomba. Nunca manipule una bomba con las manos mojadas ni cuando esté parado sobre una superficie húmeda o en el agua. Podría ocurrir una descarga eléctrica fatal. PROBLEMA CAUSA POSIBLE ACCIÓN CORRECTIVA...

This manual is also suitable for:

5cdh

Table of Contents