NOTIFICATIONS · Explanation of descriptions There are five different levels of notification intensity within this manual, as identified by the signal terms: DANGER, WARNING, IMPORTANT, NOTE and PRO TIP. The level of risk and importance of the notification is determined by the following definitions. Always observe the warnings to ensure safety and prevent potential injury and product damage.
CHANGING THE GROUP GASKET · All versions 1. To remove the porta-filter, use 2. Remove the shower and 3. Remove and discard the old a straight-blade screwdriver to gasket. gasket. Insert the new gasket release the shower by prying (chamfer and EXPOBAR logo down with medium force.
PRESSURE SETTINGS · Pump pressure adjustment Fix Nut Screw 1. Remove the drip tray and the splash panel 2. Pump pressure adjustment: - Loose the fixation nut of the adjustment screw (A). to acces to the pump head. The pump head will be located on the left side of the machine - Adjust the pump pressure (B).
BUTTONS AND CONTROLS · Machine controls EX3 features a push button control block for each brewing group. Control functions are explained below. Versions with display (PID) are equipped with an individual 3 digit display on each group for monitoring machine status, performing user programming and machine adjustments. (One set per group) * Disabled by default after PCB factory preset Control...
SERVICE PROGRAMMING · Stand-by [oFF] status [oFF] To put the machine on electronic Stand-by mode from home screen, press K5 and then K3 [oFF] at the same time. Message is shown on the display. On this mode, the heating element will remain disconnected. To exit from the Stand-by mode, just press any button (K1 –...
SERVICE PROGRAMMING · toU – Boiler filling Time-out To change the boiler filling time-out, follow the steps below: 1. Enter the service programming and browse through the menu (see previous instructions). [toU] 2. When is shown on the display, enter by pressing K5. 3.
SERVICE PROGRAMMING · tEA – Enabling/Disabling automatic hot water function To enable or disable the automatic hot water functions, follow the steps below: 1. Enter the service programming and browse through the menu (see previous instructions). [tEA] 2. When is shown on the display, enter by pressing K5. [oFF] [on] 3.
SERVICE PROGRAMMING · SLA – Service liter alarm (Water filter maintenance) To change the Service liter alarm, follow the steps below: 1. Enter the service programming and browse through the menu (see previous instructions). [SLA] 2. When is shown on the display, enter by pressing K5. 3.
SERVICE PROGRAMMING · Sb – PID band zone To change the PID band zone, follow the steps below: 1. Enter the service programming and browse through the menu (see previous instructions). [Sb] 2. When is shown on the display, enter by pressing K5. 3.
MACHINE ALERTS · Alarms and warnings To alert users that routine service of the machine is due or against a situation that could possibly cause damage to the machine, EX-Line has the following alerts programmed into its software: Display versions Display Warning Machine status...
TROUBLESHOOTING · Machine faults Problem Possible cause Solution Check that the plug is correctly The plug is not correctly inserted inserted and that the power into the power socket socket is operational. The machine does not start up The circuit breaker and/or when turned on Check that they are connected.
The warranty will not cover damages of defects caused by incorrect handling and operation of the appliance. For service Please contact your dealer Your Dealer Crem International Spain S.L.U. C/ Comerç nº 4 - Pol. Ind. Alcodar, 46701 - Gandía (Valencia – Spain) crem.coffee...