Hide thumbs Also See for EX Series:
Table of Contents

Advertisement

Quick Links

Crafted for every taste
L I N E
SM_EN
Part No.: 1964229
SERVICE MANUAL
Rev.:
07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EX Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Crem EX Series

  • Page 1 Crafted for every taste L I N E SM_EN Part No.: 1964229 SERVICE MANUAL Rev.:...
  • Page 2: Table Of Contents

    CONTENTS CONTENTS MANUAL REVISIONS NOTIFICATIONS · Explanation of descriptions ROUTINE MAINTENANCE SCHEDULE · Service intervals CHANGING THE GROUP GASKET · All versions PRESSURE SETTINGS · Pump pressure adjustment · Steam Boiler Pressure adjustment (machines with pressure switch only) · Element Hight Limit Switch BUTTONS AND CONTROLS ·...
  • Page 3: Manual Revisions

    CONTENTS · Ui – User Interface · AUt – Enabling/Disabling Auto On/Off function · con – Connectivity ELECTRICAL DIAGRAMS · PCB & LED lights connections - EX3 Display PID Versions ELECTRICAL DIAGRAMS · PCB & LED lights connections - EX3 Display PID SmartSteam Versions ·...
  • Page 4: Notifications

    NOTIFICATIONS · Explanation of descriptions There are five different levels of notification intensity within this manual, as identified by the signal terms: DANGER, WARNING, IMPORTANT, NOTE and PRO TIP. The level of risk and importance of the notification is determined by the following definitions. Always observe the warnings to ensure safety and prevent potential injury and product damage.
  • Page 5: Routine Maintenance Schedule

    ROUTINE MAINTENANCE SCHEDULE · Service intervals Months (Cycles) Main Part No. components 6 (12500) 12 (25000) 18 (37500) 24 (50000) Boiler Non suction valve 65000210 Check Check Check Replace Boiler filling solenoid 60000201 Replace valve Boiler upper raccord 30000200 Check* Check* Boiler lower raccord 30000210...
  • Page 6: Changing The Group Gasket

    CHANGING THE GROUP GASKET · All versions 1. To remove the porta-filter, use 2. Remove the shower and 3. Remove and discard the old a straight-blade screwdriver to gasket. gasket. Insert the new gasket release the shower by prying (chamfer and EXPOBAR logo down with medium force.
  • Page 7: Pressure Settings

    PRESSURE SETTINGS · Pump pressure adjustment Fix Nut Screw 1. Remove the drip tray and the splash panel 2. Pump pressure adjustment: - Loose the fixation nut of the adjustment screw (A). to acces to the pump head. The pump head will be located on the left side of the machine - Adjust the pump pressure (B).
  • Page 8: Buttons And Controls

    BUTTONS AND CONTROLS · Machine controls EX3 features a push button control block for each brewing group. Control functions are explained below. Versions with display (PID) are equipped with an individual 3 digit display on each group for monitoring machine status, performing user programming and machine adjustments. (One set per group) * Disabled by default after PCB factory preset Control...
  • Page 9: Service Programming

    SERVICE PROGRAMMING · Stand-by [oFF] status [oFF] To put the machine on electronic Stand-by mode from home screen, press K5 and then K3 [oFF] at the same time. Message is shown on the display. On this mode, the heating element will remain disconnected. To exit from the Stand-by mode, just press any button (K1 –...
  • Page 10: Tou - Boiler Filling Time-Out

    SERVICE PROGRAMMING · toU – Boiler filling Time-out To change the boiler filling time-out, follow the steps below: 1. Enter the service programming and browse through the menu (see previous instructions). [toU] 2. When is shown on the display, enter by pressing K5. 3.
  • Page 11: Tea - Enabling/Disabling Automatic Hot Water Function

    SERVICE PROGRAMMING · tEA – Enabling/Disabling automatic hot water function To enable or disable the automatic hot water functions, follow the steps below: 1. Enter the service programming and browse through the menu (see previous instructions). [tEA] 2. When is shown on the display, enter by pressing K5. [oFF] [on] 3.
  • Page 12: Sla - Service Liter Alarm (Water Filter Maintenance)

    SERVICE PROGRAMMING · SLA – Service liter alarm (Water filter maintenance) To change the Service liter alarm, follow the steps below: 1. Enter the service programming and browse through the menu (see previous instructions). [SLA] 2. When is shown on the display, enter by pressing K5. 3.
  • Page 13: Sb - Pid Band Zone

    SERVICE PROGRAMMING · Sb – PID band zone To change the PID band zone, follow the steps below: 1. Enter the service programming and browse through the menu (see previous instructions). [Sb] 2. When is shown on the display, enter by pressing K5. 3.
  • Page 14: Electrical Diagrams

    ELECTRICAL DIAGRAMS · PCB & LED lights connections - EX3 Display PID Versions OUT3...
  • Page 15: Electrical Diagrams

    ELECTRICAL DIAGRAMS · PCB & LED lights connections - EX3 Display PID Versions EX3 Display PID 1Ph+N 220-240V Mini 1GR Mini 2GR & 2GR...
  • Page 16: Pcb & Led Lights Connections - Ex3 Display Pid Smartsteam Versions

    ELECTRICAL DIAGRAMS · PCB & LED lights connections - EX3 Display PID SmartSteam Versions...
  • Page 17 ELECTRICAL DIAGRAMS · PCB & LED lights connections - EX3 Display PID SmartSteam Versions Mini 1GR Mini 2GR & 2GR...
  • Page 18 ELECTRICAL DIAGRAMS · Power diagram - EX3 MINI 1Gr & MINI 2Gr Display PID - 1Ph+N 220-240V...
  • Page 19: Power Diagram - Ex3 2Gr Display Pid - 1Ph+N 220-240V

    ELECTRICAL DIAGRAMS · Power diagram - EX3 2Gr Display PID - 1Ph+N 220-240V...
  • Page 20: Power Diagram - Ex3 2Gr Display Pid - 3Ph+N 380-415V

    ELECTRICAL DIAGRAMS · Power diagram - EX3 2Gr Display PID - 3Ph+N 380-415V...
  • Page 21: Power Diagram - Ex3 3Gr Display Pid - 2Ph+N 380-415V

    ELECTRICAL DIAGRAMS · Power diagram - EX3 3Gr Display PID - 2Ph+N 380-415V...
  • Page 22: Power Diagram - Ex3 3Gr Display Pid - 3Ph+N 380-415V

    ELECTRICAL DIAGRAMS · Power diagram - EX3 3Gr Display PID - 3Ph+N 380-415V...
  • Page 23: Power Diagram - Ex3 3Gr Display Pid - 1Ph+N 220-240V

    ELECTRICAL DIAGRAMS · Power diagram - EX3 3Gr Display PID - 1Ph+N 220-240V...
  • Page 24: Pcb & Led Lights Connections - Ex3/Ex2 Control Versions

    ELECTRICAL DIAGRAMS · PCB & LED lights connections - EX3/EX2 Control Versions OUT3...
  • Page 25 ELECTRICAL DIAGRAMS · PCB & LED lights connections - EX3/EX2 Control Versions EX CONTROL 1Ph+N 220-240V Mini 1GR Mini 2GR & 2GR...
  • Page 26 ELECTRICAL DIAGRAMS · Power diagram - EX3/EX2 MINI 1Gr & MINI 2Gr Control - 1Ph+N 220-240V...
  • Page 27: Power Diagram - Ex3/Ex2 2Gr Control - 1Ph+N 220-240V

    ELECTRICAL DIAGRAMS · Power diagram - EX3/EX2 2Gr Control - 1Ph+N 220-240V...
  • Page 28: Power Diagram - Ex3 2Gr Control - 3Ph+N 380-415V

    ELECTRICAL DIAGRAMS · Power diagram - EX3 2Gr Control - 3Ph+N 380-415V...
  • Page 30: Machine Alerts

    MACHINE ALERTS · Alarms and warnings To alert users that routine service of the machine is due or against a situation that could possibly cause damage to the machine, EX-Line has the following alerts programmed into its software: Display versions Display Warning Machine status...
  • Page 31: Troubleshooting

    TROUBLESHOOTING · Machine faults Problem Possible cause Solution Check that the plug is correctly The plug is not correctly inserted inserted and that the power into the power socket socket is operational. The machine does not start up The circuit breaker and/or when turned on Check that they are connected.
  • Page 32: For Service

    The warranty will not cover damages of defects caused by incorrect handling and operation of the appliance. For service Please contact your dealer Your Dealer Crem International Spain S.L.U. C/ Comerç nº 4 - Pol. Ind. Alcodar, 46701 - Gandía (Valencia – Spain) crem.coffee...

This manual is also suitable for:

Ex2Ex3Ex3 mini 1grEx3 mini 2grEx3 mini 3grEx2 mini 1gr ... Show all

Table of Contents