Advertisement

Quick Links

DYMOND MODULE
INSTALLATION
MANUAL
For professional use only

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DYMOND CS6K-245P-FG and is the answer not in the manual?

Questions and answers

Summary of Contents for CanadianSolar DYMOND CS6K-245P-FG

  • Page 1 DYMOND MODULE INSTALLATION MANUAL For professional use only...
  • Page 2 EN-Rev IM-FDM-EN/1.2 Copyright © Jan. 2016. Canadian Solar Inc.
  • Page 3: Table Of Contents

    MECHANICAL / ELECTRICAL SPECIFICATIONS UNPACKING AND STORAGE MODULE INSTALLATION MODULE WIRING MODULE GROUNDING MOUNTING INSTRUCTIONS MAINTENANCE | 10 AMENDED EDITIONS AND DATES | 10 ANNEX A: MECHANICAL AND ELECTRICAL RATINGS | 11 ANNEX B: DOUBLE GLASS MODULE INSTALLATION MANUEL SUPPLEMENT www.canadiansolar.com...
  • Page 4: General Information

    CS6K-P-FG and CS6X-P-FG. Please retain entraîner des blessures ou la mort, this manual for future reference. We recommend que le panneau soit connecté ou non. www.canadiansolar.com visiting regularly for the most updated version. GENERAL SAFETY ·...
  • Page 5: Mechanical / Electrical Specifications

    (giving a total multiplier of 1.56), may be applicable · Do not carry modules on your head. when sizing conductors and fuses, as described in section 690-8 of U.S. NEC. · Do not use sharp instruments on the modules. www.canadiansolar.com...
  • Page 6: Module Installation

    Do not SYSTEM FIRE RATING · place modules on top of each other Do not · leave modules unsupported or unsecured. · The fire rating for this module is only valid when the product is installed as specified in the mechani- ·...
  • Page 7: Module Wiring

    Connectors should only be used to connect the circuit. They should never · Modules should be safely fixed to bear all expected be used to turn the circuit on and off. loads, including wind and snow loads. www.canadiansolar.com...
  • Page 8: Module Grounding

    USE OF SUITABLE MATERIALS STANDARD MODULES For a clear understanding of our modules, please · Only use dedicated solar cable and suitable plugs refer to the illustration of a module shown below: (wiring should be sheathed in a sunlight-resistant conduit or, if exposed, should itself be sunlight- resistant) that meet local fire, building and electrical regulations.
  • Page 9: Maintenance

    · Please refer to our Installation Manual Annex Rail Bolt Bottom End Clamp Glass (Section Annex D: Module Cleaning Guideline) for www.canadiansolar.com...
  • Page 10: Amended Editions And Dates

    10 | more information on module cleaning. AMENDED EDITIONS AND DATES · Rev 1.0 is released in June. 2015 · Rev 1.1 is released in Aug. 2015. · Rev 1.2 is released in Jan. 2016. ANNEX A: MECHANICAL AND ELECTRICAL RATINGS Standard Test Conditions are: irradiance of 1 kW/m es for Isc, Voc and Pmax.
  • Page 11: Annex B: Double Glass Module

    A=380±20 mm, Downforce load≤2400 Pa VDE/CSA EC-L100 four clamps Uplift load ≤2400 Pa (End clamp) Xiamen Grace SolarTechnology co.,ltd. GS-IC-L200 (Middle clamp) / GS- A=380±20 mm, Downforce load≤5400 Pa VDE/CSA EC-L200 four clamps Uplift load ≤2400 Pa (End clamp) www.canadiansolar.com...
  • Page 12 CLAMPING LOCATION ILLUSTRATION Clamping on module long side, four clamp points; Mounting rails must run perpendicularly to the mo- dule long side; CANADIAN SOLAR INC. 545 Speedvale Avenue West, Guelph, Ontario, Canada N1K 1E6 www.canadiansolar.com...

Table of Contents