ELECTRICAL REQUIREMENTS
-
cont'd
DOUBLE INSULATED
[]
The power tool is double insulated to provide a double
thickness of insulation between you and tool's electrical
system. All exposed metal parts are isolated from
the internal metal motor components with protecting
insulation.
Replacement
parts - When servicing, use only
identical replacement parts.
Polarized
plugs - This saw has a plug that looks like
the one shown below:
To reduce the risk of electrical shock, this saw has a
polarized plug (one blade is wider than the other). This
plug will fit in a polarized outlet only one way. If the plug
does not fit fully in the outlet, reverse the plug. If it still
does not fit, contact a qualified electrician to install the
proper outlet. Do not change the plug in any way.
[,_
WARNING
]
Double insulation does not take the place of normal
safety precautions when operating this tool.
To avoid electrocution:
1. Use only identical replacement parts when servicing
a tool with double insulation. Servicing should be
performed by a qualified technician.
2. Do not use power tools in wet or damp locations or
expose them to rain or snow.
MOTOR SAFETY PROTECTION
IMPORTANT
To avoid motor damage, the motor should be blown out
or vacuumed frequently to keep sawdust from interfering
with the motor ventilation.
1.
Connect
this saw to a 120 V circuit. This circuit
must not be less than a #12 wire with a 20 A time
lag fuse or a #14 wire with a 15 A time lag fuse.
NOTE: When using an extension cord on a circuit
with a #14 wire, the extension cord must not exceed
25 feet in length.
2.
If the motor will not start, release the trigger switch
immediately. UNPLUG THE SAW. Check the saw
blade to make sure it turns freely. If the blade is free,
try to start the saw again. If the motor still does not
start, refer to the TROUBLESHOOTING
GUIDE.
3.
If the tool suddenly stalls while cutting wood, release
the trigger switch, unplug the tool and free the blade
from the wood. The saw may now be started and
the cut finished.
6
4.
FUSES may "blow" or circuit breakers may trip
frequently if:
a. MOTOR is overloaded - overloading can occur
if you feed too rapidly or make too many start/
stops in a short time.
b. LINE VOLTAGE is more than 10% above or
below the nameplate voltage rating. For heavy
loads, the voltage at motor terminals must equal
the voltage specified on the nameplate.
c. IMPROPER or dull saw blades are used.
5.
Most motor troubles may be traced to loose or
incorrect connections, overload, low voltage or
inadequate power supply wiring. Always check the
connections, the load and supply circuit if the motor
doesn't run well. Check minimum gauge for the
length of cord you are using on the chart below.
GUIDELINES
FOR EXTENSION CORDS
Use a proper extension cord. Make sure your extension
cord is in good condition. When using an extension
cord, be sure to use one heavy enough to carry the
current your product will draw. An undersized cord will
cause a drop in line voltage, resulting in loss of power
and overheating. The table below shows the correct size
to use depending on cord length and nameplate ampere
rating. If in doubt, use the next heavier gauge. The
smaller the gauge number, the heavier the cord.
Be sure your extension cord is properly wired and
in good condition. Always replace a damaged extension
cord or have it repaired by a qualified person before
using it. Protect your extension cords from sharp
objects, excessive heat and damp or wet areas.
Use a separate electrical
circuit
for your tools. This
circuit must not be less than a #12 wire with a 20 A
time lag fuse or a #14 wire with a 15 A time lag fuse.
NOTE: When using an extension cord on a circuit with
a #14 wire, the extension cord must not exceed 25 feet
in length. Before connecting the tool to the power line,
make sure the switch is in the OFF position and the
electric current is rated the same as the current stamped
on the motor nameplate, running at a lower voltage will
damage the motor.
(When using 120 volts only)
Ampere Rating
Total length of Cord
More Than
Not MoreThan 25ft.
50ft.
100ft.
150ft.
0
6
18
16
16
14
6
10
18
16
14
12
10
12
16
16
14
12
CAUTION:
In all cases
make
certain
the receptacle
in
question
is properly
grounded.
If you are not sure,
have a certified
electrician
check the receptacle.