Gigabyte GS-R114V System Installation Manual page 52

1u rack mount server
Table of Contents

Advertisement

GS-R114V Rack Mount Server
Post Error Pause
If this item is set to enabled, the system will wai for user intervention on critical POST errors. If
this item is disabled, the system will boot with no intervention if possible.
Enabled
Disabled
AC-LINK
This option provides user to set the mode of operation if an AC / power loss occurs.
Power On
Stay Off
Last State
Mini BMC Function
Enabled
Disabled
This option will disappear and disable when BMC module is populated.
Mini BMC SEL View
Press [Enter] to view the Mini BMC SEL.
This option will disappear and disable when BMC module is populated.
Log POST System Event
Enabled
Disabled
Event Log Viewer
Enabled
Disabled
This option will appear when BMC module is populated.
(Default value)
Enable Post Error Pause.
Disable this function.
System power state when AC cord is re-plugged.
Do not power on system when AC power is back.
Set system to the last sate when AC power is removed. Do not power on
system when AC power is back. (Default value)
Enable Mini BMC function. (Default value)
Disable this function.
Enable Log POST System Event. (Default value)
Disable this function.
Enable Event Log Viewer function(Default value)
Disable this function.