Gigabyte GS-R113V-RH System Installation Manual
Gigabyte GS-R113V-RH System Installation Manual

Gigabyte GS-R113V-RH System Installation Manual

Gs-r113-rh series 1u rack mount server

Advertisement

Quick Links

GS-R113-RH Series
GS-R113V-RH
GS-R113L-RH
(OEM Model)
1U Rack Mount Server
System Installation Guide
AMD
AM2 Processor Motherboard
®
Rev. 1.1

Advertisement

Table of Contents
loading

Summary of Contents for Gigabyte GS-R113V-RH

  • Page 1 GS-R113-RH Series GS-R113V-RH GS-R113L-RH (OEM Model) 1U Rack Mount Server System Installation Guide AM2 Processor Motherboard ® Rev. 1.1...
  • Page 2: Table Of Contents

    GS-R113L-RH (OEM Model) ..................16 Step 2-7: FAN Duct Removal and Installation .............. 17 Chapter 3 Appearance of GS-R113-RH ..........18 3-1: Front View of GS-R113V-RH .................. 18 3-2: Front View of GS-R113L-RH (OEM Model) ............18 3-3: Rear View of GS-R113L-RH/GS-R113V-RH ............19 3-4: Switch and LED Indicators Introduction ..............
  • Page 3 Table of Content Chapter 5 BIOS Setup ................28 Main ......................30 Advanced ....................35 Advanced BIOS Feature ....................36 Advanced Chipset ......................39 Integrated Peripherals ...................... 41 Power Management Setup ..................... 49 PnP/PCI Configuration ..................... 51 Security ...................... 53 Boot ......................
  • Page 4: Safety, Care And Regulatory Information

    GS-R113-RH Series Rack Mount Server Safety, Care and Regulatory Information Important safety information Read and follow all instructions marked on the product and in the documentation before you operate your system. Retain all safety and operating instructions for future use. * The product should be operated only from the type of power source indicated on the rating label.
  • Page 5 Safety Information * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem or telephone cable into the network interface controller (NIC) receptacle. * Disconnect the modem cable before opening a product enclosure, touching or installing internal components, or touching an uninsulated modem cable or jack.
  • Page 6 GS-R113-RH Series Rack Mount Server Your telephone company may make changes in its facilities, equipment, operations, or procedures that could affect proper operation of your equipment. If they do, you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service. The FCC prohibits this equipment to be connected to party lines or coin-telephone service.
  • Page 7: Warning

    Safety Information NOTICE: The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the sum of the Load Numbers of all the devices does not exceed 100.
  • Page 8: Introduction

    For your protection, please read and undertand all of the safety and operating instructions regarding your Gigabyte Server and retain for future reference. The procedures in this guidebook assume that your are a system or network administrator experienced in installing similar hardware.
  • Page 9: Chapter 1Features Summary

    Integrated in NVIDIA GeForce 6100 Chipset ® Graphics Memory 256MB (Shared) Mass Storage System 2 x Internal SATA HDDs (GS-R113L-RH) 2 x hot-swap SATA HDDs (GS-R113V-RH) 1 x Standard Type FDD 1 Slim Type CD-ROM Super I/O Controller ITE IT8712F-A...
  • Page 10 GS-R113-RH Series Rack Mount Server Built-in I/O 2 x Serial port (1 by cable) 3 x USB 2.0 connectors (2x rear USB, 1x Front USB) 1 x VGA connector 2 x RJ45 LAN ports P/S 2 Keyboard and Mouse Connectors 1 x RJ45 on front for console redirection System BIOS: BIOS Type...
  • Page 11: Chapter 2 System Hardware Installation

    Hardware Installation Process Chapter 2 System Hardware Installation Please observe the safety information in chapter “Important Safety Information” Do not expose the server to extreme environmental conditions. Protect it from dust, humidity, and heat. Step 2-1: Chassis Removal and Installation Step 1 Loosen the thumbscrew from the back of the server.
  • Page 12: Step 2-2: Cpu Installation

    GS-R113-RH Series Rack Mount Server Step 2-2: CPU Installation Please make sure the CPU type and speed that are supported by the motherboard. Step 1. Check the CPU pins are not bent. Raise the locking lever next to the socket prior to installing the CPU.
  • Page 13: Step 2-3: Heat Sink Installation

    Hardware Installation Process Step 2-3: Heat Sink Installation Step 1 Place the Heat Sink on the CPU. Before putting the heat sink on the CPU, please well remember to apply the thermal conductivity compound on the CPU. Step 2 Seat the heat sink in the retention modules with the four screws. Installation completed. Step 2-4: Memory Installation Step 1.
  • Page 14: Step 2-5: Pci Expansion Card Installation

    GS-R113-RH Series Rack Mount Server Step 2-5: PCI Expansion Card Installation GS-R113-RH Series provides expansion riser slots for one PCI 32/33MHz slot and one PCI-E x8 slot. To install the peripheral, please go through the following steps. Note!! Before installing the PCI expansion card, please check the card size limitation. Size limitation for PCI-X full-height/full-length is 228.5 mm x 91.5 mm;...
  • Page 15: Step 2-6: Hard Disk Drive Installation

    Hardware Installation Process Step 2-6: Hard Disk Drive Installation GS-R113V-RH Step 1 Press the release button and pull the blank out of the drive bay. Step 2 Slide hard disk into blank and secure it with screws Step 3 To replace the hard drive blank, slide the blank into the bay until it locks into place. Connect cable and power.
  • Page 16: Gs-R113L-Rh (Oem Model)

    GS-R113-RH Series Rack Mount Server GS-R113L-RH (OEM Model) Step 1 Lossen the screws securing the hard drive plate. Step 2 Slide toward to remove the hard drive plate from system. Step 3 Place hard disk on the plate and lock hard drive with 4 screws. Step 4 Replace the hard drive plate, slide the blank into the bay until it locks into place.Connect HDD power cable.
  • Page 17: Step 2-7: Fan Duct Removal And Installation

    Hardware Installation Process Step 2-7: FAN Duct Removal and Installation Step 1 Lift up to remove the fan duct. Step 2 To Install the FAN Duct, just simply place the fan duct on the top of heat sink.
  • Page 18: Chapter 3 Appearance Of Gs-R113-Rh

    GS-R113-RH Series Rack Mount Server Chapter 3 Appearance of GS-R113-RH 3-1: Front View of GS-R113V-RH 3-2: Front View of GS-R113L-RH (OEM Model)
  • Page 19: 3-3: Rear View Of Gs-R113L-Rh/Gs-R113V-Rh

    System Appearance 3-3: Rear View of GS-R113L-RH/GS-R113V-RH t r o t r o e l i f t o l l l u i s - l l u e l - t o l r o t r o t &...
  • Page 20: 3-4: Switch And Led Indicators Introduction

    GS-R113-RH Series Rack Mount Server 3-4: Switch and LED Indicators Introduction Reset BTN Power/Sleep LAN1/2 Activities Color Condition Description Name Green Power On Power Green Blink Sleep (S1) Power Off (S4/S5) Green Blink Hard Disk Drive Access No Access and No HDD Fault LAN1 Green LAN Link / No access...
  • Page 21 LED Description NOTE!! To make LAN 2 LED work properly, please follow the instrctions illustrated below: Step 1. Right click My Computer and select Manage. Step 2. Select Device Manager from the left window and select Manage.
  • Page 22 GS-R113-RH Series Rack Mount Server Step 3. In the right window, right click Marvell Yukon 88E8056 PCI-E Gigabit Ethernet Controller and select Properties. Step 4. Select Wake From Shutdown in the Property selection list and select On, click OK. Configuration is completed.
  • Page 23: 3-5: Lan Led Description

    LED Description 3-5: LAN LED Description Name Color Condition Description Green LAN Link / no Access Link/Activity Green BLINK LAN Access Idle GbE LAN Yellow 1Gbps connection Speed Green 100Mbps connection 10Mbps connection NOTE!! To make LAN 2 LED work properly, please see page 21 and 22 for detail instruction.
  • Page 24: 3-6 : Connector Icon Description

    GS-R113-RH Series Rack Mount Server 3-6 : Connector Icon Description i r c i t p l a i...
  • Page 25: Chapter 4 Motherboard Layout & Jumper Setting

    Motherboard Layout Chapter 4 Motherboard Layout & Jumper Setting 4-1: GA-3PXSL1-RH Motherboard Components...
  • Page 26 GS-R113-RH Series Rack Mount Server AMD Opteron/Socket AM2 COM2 NVIDIA GeForce 6100 System Fan1 NVIDIA nForce 430 System Fan2 ITE 8712F-A System Fan3 BIOS Flash System Fan4 Marvel 8056 GbE System Fan5 Marvel 88E1116 GbE PHY 22 Slot for Riser Card Floppy Connector DDRA1 IDE1 Connector...
  • Page 27: 4-2: Jumper Setting

    Jumper Setting 4-2: Jumper Setting CLR_CMOS ( (Clear CMOS Function) You may clear the CMOS data to its default values by this jumper. Default value doesn’t include the “Shunter” to prevent from improper use this jumper. To clear CMOS, temporarily short 1-2 pin. CLR_CMOS 1-2 close: Clear CMOS 2-3 close: Normal (Default value)
  • Page 28: Chapter 5 Bios Setup

    GS-R113-RH Series Rack Mount Server Chapter 5 BIOS Setup BIOS Setup is an overview of the BIOS Setup Program. The program that allows users to modify the basic system configuration. This type of information is stored in battery-backed CMOS RAM so that it retains the Setup information when the power is turned off.
  • Page 29: Getting Help

    BIOS Setup GETTING HELP Main Menu The on-line description of the highlighted setup function is displayed at the bottom of the screen. Status Page Setup Menu / Option Page Setup Menu Press F1 to pop up a small help window that describes the appropriate keys to use and the possible selections for the highlighted item.
  • Page 30: Main

    GS-R113-RH Series Rack Mount Server Main Once you enter Phoenix BIOS Setup Utility, the Main Menu (Figure 1) will appear on the screen. Use arrow keys to select among the items and press <Enter> to accept or enter the sub-menu. Phoenix-Award WorkstationBIOS CMOS Setup Utility Main Advanced...
  • Page 31: System Information

    BIOS Setup Phoenix-Award WorkstationBIOS CMOS Setup Utility Main Advanced Security Boot PC Health Exit System Information Item Help *************** System Information *************** Product Name: GS-R113L_V BIOS Version: Build Date: xx-xx-xx Manufactory: Chipset Type: LAN1 MAC Address: LAN2 MAC Address: CPU Core Frequency CPU Frequency Ratio CPU L1 Cache CPU L2 Cache...
  • Page 32 GS-R113-RH Series Rack Mount Server IDE HDD Auto Detection Press [Enter] to auto-detect the HDD’s size, head, etc on this channel. IDE Channel 0~5 Master / Channel 0~1 Slave The category identifies the types of hard disk from drive C to F that has been installed in the computer. There are two types: auto type, and manual type.
  • Page 33 BIOS Setup Drive A The category identifies the types of floppy disk drive A that has been installed in the computer. None No floppy drive installed 360K, 5 5.25 inch PC-type standard drive; 360K byte capacity. 1.2M, 5 5.25 inch AT-type high-density drive; 1.2M byte capacity (3.5 inch when 3 Mode is Enabled).
  • Page 34: Base Memory

    GS-R113-RH Series Rack Mount Server Base Memory The POST of the BIOS will determine the amount of base (or conventional) memory installed in the system. Extended Memory The BIOS determines how much extended memory is present during the POST. This is the amount of memory located above 1 MB in the C PU’s memory address map.
  • Page 35: Advanced

    BIOS Setup Advanced Phoenix-Award WorkstationBIOS CMOS Setup Utility Main Advanced Security Boot PC Health Exit Advanced BIOS Feature Item Help Advanced Chipset Integrated Peripherals Power Management Setup PnP/PCI Configuration : Move Enter: Select +/-/PU/PD: Value F10: Save ESC: Exit F1: General Help F5: Previous Values F7: Optimized Defaults Figure 2: Advanced...
  • Page 36: Advanced Bios Feature

    GS-R113-RH Series Rack Mount Server Advanced BIOS Feature Phoenix-Award WorkstationBIOS CMOS Setup Utility Advanced Advanced BIOS Feature Item Help Quick Power On Self Test [Enabled] Boot Up Floppy Seek [Disabled] Boot Up Num-Lock Status [On] APIC Mode Enabled Full Screen LOGO Show [Disabled] Summary Screen Show [Enabled]...
  • Page 37: Dmi Event Log

    BIOS Setup Boot Up Floppy Seek During POST, BIOS will determine the floppy disk drive installed is 40 or 80 tracks. 360K type is 40 tracks 720K, 1.2M and 1.44M are all 80 tracks. Enabled BIOS searches for floppy disk drive to determine it is 40 or 80 tracks.
  • Page 38 GS-R113-RH Series Rack Mount Server View DMI Event Log Press [Enter] to view all DMI event logs. Mark DMI Events Log as Read This option allows user to clear all DMI Event Logs immediately. Press [Enter] will pop up a confirmation window.
  • Page 39: Advanced Chipset

    BIOS Setup Advanced Chipset Phoenix-Award WorkstationBIOS CMOS Setup Utility Advanced Advanced Chipset Item Help OnChip VGA [Enabled] Frame Buffer Size [64M] [Auto] DRAM Configuration [Press Enter] DRAM ECC enable [Disabled] x DRAM MCE enable [Disabled] System BIOS Cacheable [Disabled] : Move Enter: Select +/-/PU/PD: Value F10: Save ESC: Exit F1: General Help F5: Previous Values...
  • Page 40 GS-R113-RH Series Rack Mount Server DRAM MCE enable Enabled Enable memory MCE function Disabled Disabled this function. (Default setting) System BIOS Cacheable Enabled Enable System BIOS Cacheable function. Disabled Disabled this function. (Default setting)
  • Page 41: Integrated Peripherals

    BIOS Setup Integrated Peripherals Phoenix-Award WorkstationBIOS CMOS Setup Utility Advanced Integrated Peripherals Item Help IDE Function Setup RAID Config OnChip USB [V1.1+V2.0] USB Memory Type [SHADOW] USB Keyboard Support [Disabled] USB Mouse Support [Disabled] MAC Lan [Auto] MAC Media Interface [Pin Strap] 2nd Lan Controller [Auto]...
  • Page 42 GS-R113-RH Series Rack Mount Server IDE Function Setup OnChip IDE Channel 0 Enabled Enable onboard Onchip IDE Channel 0. (Default setting) Disabled Disable this function. Primary Master PIO Auto Auto detect the IDE secondary master PIO. (Default setting) Mode 0 Select Mode 0 as IDE secondary master PIO.
  • Page 43 BIOS Setup OnChip IDE Channel 1 Enabled Enable onboard Onchip IDE Channel 0. (Default setting) Disabled Disable this function. Secondary Master PIO Auto Auto detect the IDE secondary master PIO. (Default setting) Mode 0 Select Mode 0 as IDE secondary master PIO. Mode 1 Select Mode 1 as IDE secondary master PIO.
  • Page 44 GS-R113-RH Series Rack Mount Server IDE DMA transfer access Enabled Enable IDE DMA transfer access. (Default setting) Disabled Disable this function. Serial-ATA Controller All Enabled Enable all serial device controllers. (Default setting) Disabled Disable this device. SATA-1 Only enable SATA-1 device. IDE Prefetch Mode Enabled Enable IDE Prefetch Mode.
  • Page 45 BIOS Setup RAID Enable Enabled Enable RAID function. Disabled Disable this function. (Default setting) SATA1 Primary RAID Enabled Enable SATA1 Primary RAID function. Disabled Disable this function. (Default setting) SATA1 Secondary RAID Enabled Enable SATA1 Secondary RAID function. Disabled Disable this function. (Default setting) SATA2 Primary RAID Enabled Enable SATA1 Primary RAID function.
  • Page 46 GS-R113-RH Series Rack Mount Server OnChip USB Options V1.1+V2.0, V1.1, Disabled. Default value is V1.1+V2.0 USB Memory Type Options SHADOW, Base Memory (640K). USB Keyboard Support Enabled Enable USB Keyboard Support. Disabled Disable USB Keyboard Support. (Default setting) USB Mouse Support Enabled Enable USB Mouse Support.
  • Page 47 BIOS Setup 2nd LAN Controller Auto Auto detect onboard second H/W LAN. (Default setting) Disabled Disable this function. IDE HDD Block Mode The IDE HDD Block Mode feature speeds up hard disk access by transferring data from multiple sectors at once instead of using the old single sector transfer mode. When you enable it, the BIOS will automatically detect if your hard disk supports block transfers and configure the proper block transfer settings for it.
  • Page 48 GS-R113-RH Series Rack Mount Server UART Mode Select Normal Using as standard serial port. (Default setting) IrDA Using as IR and set to IrDA mode. ASKIR Using as IR and set to ASKIR mode. SCR Using as Smart Card Interface. UR2 Duplex Mode This entry can be adjust when user select [IrDA] in UART Mode item.
  • Page 49: Power Management Setup

    BIOS Setup Power Management Setup Phoenix-Award WorkstationBIOS CMOS Setup Utility Advanced Power Management Item Help ACPI Function [Enabled] ACPI Suspend Type [S1,S3] Power Management [User Define] Video off Method [DPMS Support] HDD Power Down [Disabled] HDD Down In Suspend [Disabled] Soft-off by PBNT [Instant-off] AC Back...
  • Page 50 GS-R113-RH Series Rack Mount Server ACPI Function Enabled Enable ACPI function. (Default setting) Disabled Disable this function. ACPI Suspend Type S1(POS) Set ACPI suspend type to S1. S3(STR) Set ACPI suspend type to S3. S1, S3 Set ACPI suspend type to S1&S3. (Default setting) Soft-off by PBTTN Instant-off Press power button then Power off instantly.
  • Page 51: Pnp/Pci Configuration

    BIOS Setup PnP/PCI Configuration Phoenix-Award WorkstationBIOS CMOS Setup Utility Advanced PnP/PCI Configuration Item Help Init Display First [PCIEx] Reset Configuration Data [Disabled] Resource Controller By [Auto (ESCD)] x IRQ Resource PCI VGA Palette Snoop [Disabled] ***** PCI Express relative items ***** Maximum Payloads Size [4096]...
  • Page 52 GS-R113-RH Series Rack Mount Server Resource Controller By This BIOS items provides function for configuring all of the boot and Plug & Play compatible devices. Normally, user should set this items Auto, then the BIOS can automatically assign the IRQs and DMA channels. All the IRQ and DMA assignment fields should disappear as a result.
  • Page 53: Security

    BIOS Setup Security Phoenix-Award WorkstationBIOS CMOS Setup Utility Main Advanced Security Boot PC Health Exit Set Supervisor Password Item Help Set User Password Supervisor Password Status Not Installed User Password Status Not Installed Security Option [Setup] : Move Enter: Select +/-/PU/PD: Value F10: Save ESC: Exit F1: General Help F5: Previous Values F7: Optimized Defaults...
  • Page 54: Boot

    GS-R113-RH Series Rack Mount Server Boot Phoenix-Award WorkstationBIOS CMOS Setup Utility Main Advanced Security Boot PC Health Exit Removable Device Priority Item Help Hard Disk Boot Priority CD-ROM Boot Priority Network Boot Priority First Boot Device [CD-ROM] Second Boot Device [Removable] Third Boot Device [Hard Disk]...
  • Page 55: Pc Health

    BIOS Setup PC Health Phoenix-Award WorkstationBIOS CMOS Setup Utility Main Advanced Security Boot PC Health Exit +12V Item Help DDR 1.8V 3VDUAL Voltage Battery System Temperature1 System Temperature2 CPU Temperature SYS Fan 1 Temperature SYS Fan 2 Temperature SYS Fan 3 Temperature SYS Fan 4 Temperature Fan Control Mode [Depend Pn CPU Temp]...
  • Page 56 GS-R113-RH Series Rack Mount Server Voltage: +12V/ DDER 1.8V/ 3VDUAL/ Voltage Battery Detect system's voltage status automatically. CPU /System 1/ System 2 Temperature Display the current CPU temperature, System1 & 2 ambient temperature. CPU SYS 1/2/3/4 FAN Speed (RPM) Display the current CPUs and System 1/23/4 FAN speed. Fan Control Mode Depend om CPU Temp Control bt CPU temperature.
  • Page 57: Exit

    BIOS Setup Exit Phoenix-Award WorkstationBIOS CMOS Setup Utility Main Advanced Security Boot PC Health Exit Load Optimized Defaults Item Help Save & Exit Setup Exit Without Saving : Move Enter: Select +/-/PU/PD: Value F10: Save ESC: Exit F1: General Help F5: Previous Values F7: Optimized Defaults Figure 7: Exit...
  • Page 58: Chapter 6 Application Driver Installation

    GS-R113-RH Series Rack Mount Server Chapter 6 Application Driver Installation NVDIA Chipset Driver Installation Insert the driver CD-title that came with your motherboard into your CD-ROM driver, the driver CD-title will auto start and show the installation guide. If not, please double click the CD-ROM device icon in "My computer", and execute the setup.exe.
  • Page 59 Driver Installation 2. InstallShield Wizard Welcome Window 2. Click "Next" to start the installation 3. Select Features 3. Select the feature setup that you want to install. And click "Next".
  • Page 60 GS-R113-RH Series Rack Mount Server 4. NVDIA IDE SW Driver Information 4. Click "Next" to process the installation. 5. IDE SW Driver Installation Confirmation Dialog 5. Click “Yes”.
  • Page 61 Driver Installation 6. Firewall and ForceWare Network Access Manager Installation Confirmation Dialog 6. Click “Yes”. 7. Network Access Manager Installation 7. Click “Next”.
  • Page 62 GS-R113-RH Series Rack Mount Server 8. Network Access Manager Setup Type Selection 8. Select the setup type and determine the driver destination folder. Click “Next” 9. Network Access Manager Installation Language Preference 9. Select the language, and click “Next”.
  • Page 63 Driver Installation 10. ActiveAmor FireWall Installation 11. Installation Complete. Restart Computer 10. Select ‘Yes, I want to restart my computer now’ and click “Finish”.
  • Page 64: B.nvidia Vga Driver Installation

    GS-R113-RH Series Rack Mount Server nVIDIA VGA Driver Installation Insert the driver CD-title that came with your motherboard into your CD-ROM driver, the driver CD-title will auto start and show the installation guide. If not, please double click the CD-ROM device icon in "My computer", and execute the setup.exe.
  • Page 65 Driver Installation 2. InstallShield Wizard Welcom Window 2. Click "Next" to start the installation 3. Installaiton Wizard Completed 3. Select ‘Yes, I want to restart my computer now’ and click “Finish”.
  • Page 66: C.marvell Lan Driver Installation

    GS-R113-RH Series Rack Mount Server Marvell LAN Driver Installation Insert the driver CD-title that came with your motherboard into your CD-ROM driver, the driver CD-title will auto start and show the installation guide. If not, please double click the CD-ROM device icon in "My computer", and execute the setup.exe.
  • Page 67 Driver Installation 2. InstallShield Wizard Welcome Window 2. Click "Next" to start the installation 3. License Agreement 2. Select “I accept the terms in the license agree- ment andclick "Next" to process the installation.
  • Page 68 GS-R113-RH Series Rack Mount Server 4. Ready to Install the Program 4. Click "Install" to start the installation 5. Installaiton Wizard Completed 4. Click "Finish". Installation Completed...
  • Page 69: D.directx 9.0 Driver Installation

    Driver Installation DirectX 9.0 Driver Installation Insert the driver CD-title that came with your motherboard into your CD-ROM driver, the driver CD-title will auto start and show the installation guide. If not, please double click the CD-ROM device icon in "My computer", and execute the setup.exe. Installation Procedures: 1.
  • Page 70 GS-R113-RH Series Rack Mount Server 2. License Agreement 2. Select “I accept the agreement andclick "Next" to process the installation. 3. Start Installaiton 3. Click “Next” to start the installation .
  • Page 71 Driver Installation 4. Installaiton Wizard completed 4. Click "Finish". Installation complete.
  • Page 72: Chapter 7 Appendix

    GS-R113-RH Series Rack Mount Server Chapter 7 Appendix 7-1: Acronyms Acronyms Meaning ACPI Advanced Configuration and Power Interface Advanced Power Management Accelerated Graphics Port Audio Modem Riser Advanced Communications Riser BIOS Boot Specification BIOS Basic Input / Output System Central Processing Unit CMOS Complementary Metal Oxide Semiconductor CRIMM...
  • Page 73 Appexdix Acronyms Meaning Input / Output IOAPIC Input Output Advanced Programmable Input Controller Industry Standard Architecture Local Area Network Logical Block Addressing Light Emitting Diode Megahertz MIDI Musical Instrument Digital Interface Memory Translator Hub Memory Protocol Translator Network Interface Card Operating System Original Equipment Manufacturer PCI A.G.P.