CMP CKIT-EX-OD-SFP Installation Manual

Gland kit

Advertisement

Quick Links

Introduction
The CKIT-EX-OD-SFP gland kit is used to connect the fiber-optic cable to the access point in explosive
atmospheres.
The CKIT-EX-OD-SFP gland kit supports multiple access point (AP) models. All installation images show the
580EX AP.
Package Contents
20A2F cable gland x1
SFP port extension x 1
Installing the SFP EX Gland Kit
Figure 1
To connect the fiber-optic cable to the access point, perform the following steps.
1. Slide the sealing nut, seal A, seal B, gland body, O-ring and SFP extension tube over the fiber-optic cable.
2. Insert the connector of the fiber-optic cable into the transceiver module, and ensure the connector is firmly
in place.
3. Screw the SFP extension tube into the SFP port and tighten to a torque of 88 in/lbs (10 Nm).
4. Place the O-ring on the gland body, and ensure it is in place.
5. Thread the gland body into the SFP extension tube and tighten to a torque of 70.5 in/lbs (8 Nm).
6. Push the seal B and seal A into the gland body and tighten the sealing nut onto the gland body to a torque of
53in/lbs (6 Nm).
For more details on the 20A2F cable gland such as conditions of use, installation instructions and technical
data, please refer to CMP website:
https://www.cmp-products.com/Installation%20Instructions/CMP%20A2F.pdf
0512215-02 | March 2022
CKIT-EX-OD-SFP Gland Kit
Fiber-optic Cable and CKIT-EX-OD-SFP Gland Kit
Fiber-optic Cable
SFP Extension Tube
O-ring
Gland Body
Seal B
Seal A
Installation Guide
Sealing Nut
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the CKIT-EX-OD-SFP and is the answer not in the manual?

Questions and answers

Summary of Contents for CMP CKIT-EX-OD-SFP

  • Page 1 CKIT-EX-OD-SFP Gland Kit Installation Guide Introduction The CKIT-EX-OD-SFP gland kit is used to connect the fiber-optic cable to the access point in explosive atmospheres. The CKIT-EX-OD-SFP gland kit supports multiple access point (AP) models. All installation images show the 580EX AP.
  • Page 2 Fiber-optic Cable and CKIT-EX-OD-SFP Gland Kit Installed to AP Figure 2 The fiber-optic cable is not included in the package and must be purchased separately. Purchase a suitable diameter 6.5 -14 mm, UV-resistant, outdoor rated cable for use with the access point.