Page 2
Components Remote pattress box Remote data cable Remote Controller pattress box Supplied with one set of your preferred control dials Piazza dial Controller data cable Tondo dial Clamping brackets & Astratta dial Controller screws...
Important information Safety information This product must be installed by a competent person in accordance with all relevant current Water Supply Regulations. ALL PRODUCTS REQUIRING AN ELECTRICAL CONNECTION MUST BE INSTALLED BY A QUALIFIED PERSON FOLLOWING THE LATEST REVISION OF BS 7671 (WIRING REGULATIONS) AND CERTIFIED TO CURRENT BUILDING REGULATIONS.
Page 4
The user control is supplied from a safety low voltage source. This product is suitable for domestic use only. Aqualisa Digital products are supplied complete with a 5 year guarantee. This product is not intended for use by persons (including children) with...
PLEASE NOTE: DUE TO PERFORMANCE CHARACTERISTICS OF COMBINATION BOILERS, SEASONAL INLET TEMPERATURE CHANGE WILL AFFECT THE PROCESSOR OUTLET FLOW RATE RESULTING IN VARYING SHOWER FLOW RATE AND FLOW CONTROL RANGE. INLET TEMPERATURE CHANGE MAY ALSO CAUSE THE TEMPERATURE LED’S TO FLASH;...
Water Supply Regulations prior to connection of the product. Declaration of Conformity Aqualisa Products Limited declares that the Infinia Controller, in conjunction with the digital processor valve, complies with the essential requirements and other relevant provisions of the Low Voltage Directive (2006/95/EC) and the EMC Directive (2004/108/EC).
INFINIA Installation In addition to the guide below it is essential that the important information section is read and understood and that you have all the necessary components before commencing installation. Failure to install the product in accordance with these instructions may adversely affect the •...
Page 8
Ensure the recess in the wall is square as this can affect how the pattress box will sit. Please note the pattress box should sit flush on the finished wall surface. • After tiling For installation in cavity walls under 30mm The data cable should be run in conduit to allow for replacement if required.
Page 9
For installation in solid walls Ensure the keyway on the control dials and spindle align at the 6 O’Clock position when pushing the control dials into place. •...
Page 10
Make sure the cable is fully inserted. • •...
Page 11
Wired remote installation Place the paper template on the wall in the desired location for the shower controller and mark all drilling points. Care should be taken to ensure the mounting holes do not pierce the data cable conduit. • Before tiling Cavity Wall Installation (instructions 3–6) Solid Wall Installation (instructions 7–9)
Page 12
After tiling For installation in cavity walls under 30mm The data cable should be run in conduit to allow for replacement if required. • Ensure the pattress box is installed in the correct orientation and ensure top is up. •...
Page 13
For installation in solid walls Carefully insert the cable into the back of the remote Make sure the cable is fully inserted. •...
Page 14
This is to check the remote is sitting square before applying silicone sealant • The wired remote control is provided and MUST be connected to the Digital diverter as shown.
Page 15
Commissioning Setting the priority outlet 1. Ensuring the processor is powered, but without any outlets flowing, select position 1 (Outlet A) or position 2 (Outlet B) on the digital diverter switch to determine the default priority outlet. 2. Replace the lid onto the diverter valve and secure using the captive screw. Setting outlet flow mode The shower is factory set to provide the following flow options: Outlet A alone or Outlet B alone.
Make sure the silicone sealant does not protrude beyond the groove as this can cause the remote to sit proud. • After installation Familiarise the end user with the Infina Digital operation and hand them the guide. Complete and post the guarantee card or register online at www.aqualisa.co.uk/guarantee...
Page 17
User guide User guide 1. Turn the temperature dial to the required position. 2. Press the ‘Start/stop’ button on the control, shower will start on priority outlet (as defined on installation). 3. The LED display will flash red in clockwise movement to indicate the shower is warming up or blue in an anti-clockwise movement to indicate the shower cooling down.
Page 18
Infinia wired remote control 1. Press the remote control ‘Start/stop’ button. ! The shower system will start in the previously selected outlet, as selected during the previous shower. ! The LED’s will flash and remain steady simultaneously with the main shower controller.
Page 19
Please note that calls may be recorded for training and aqualisa.co.uk/training quality purposes. 01959 560042 The company reserves the right to alter, change or modify the product specifications without prior warning. Part No.701670 Issue 01 Oct 15 ® Registered Trademark Aqualisa Products Limited...
Need help?
Do you have a question about the INFINIA and is the answer not in the manual?
Questions and answers