4.8
Image Quality Control
4.8.1
Image quality control unit
(1)
Open the side cover.
(2)
Remove the transfer belt unit.
P. 4-117 "4.7.3 Transfer belt unit (TBU)"
(3)
Remove the Registration roller (on the
equipment side).
P. 4-57 "4.5.8 Registration roller (on the
equipment side)"
(4)
Remove 2 screws. Disconnect 1 connector
[1] and take off the image quality control unit
[2].
Notes:
The attachment screw on the rear side is a
shoulder screw, so exercise care when
handling it during installation.
4.8.2
Paper dust holder
(1)
Remove the image quality control unit.
P. 4-134 "4.8.1 Image quality control unit"
(2)
Remove 3 screws.
(3)
Remove the paper dust holder [1].
e-STUDIO2000AC/2500AC
DISASSEMBLY AND REPLACEMENT
© 2016-2019 Toshiba Tec Corporation All rights reserved
4 - 134
Fig. 4-368
Fig. 4-369
Fig. 4-370