Page 1
® thermoport Food Transport Containers The illustrations show configuration examples, which do not necessarily have to be included in the scope of delivery. Observe the Operating Instructions Original Operating Instructions Translation of the Original Operating Instructions DOWNLOAD: USER MANUAL QR code on type plate Issue: 2025-01-13...
TP 1000 DU, TP 1000 H and TP 1000 N, (stainless steel) ................. 31 5.2.8 TP 105 L, (stainless steel) .......................... 32 5.2.9 TP actively cooled, (mobile, made of stainless steel) ................. 33 5.2.10 TP6000 Maxi for banquet solutions, (mobile, made of plastic) ..............35 Rieber GmbH & Co. KG...
Page 3
........................46 5.3.5 CHECK HACCP ............................46 5.3.6 Excerpt from the Rieber price guide ......................46 Useful Information on Delivery and Initial Cleaning .................. 47 Notes on Use ..............................48 Safety information with regard to use ......................48 ®...
2013-04-04 Implementation of QM measures 2014-11-05 Weights and max. loading added, safety note modified, structure modified according to EN 60335-1 2017-07-05 Additions; adjustment to Rieber price guide 2017-09-21 Adjustable circulating air heating; designation 2017-12-11 Small improvements 2019-02-01 Temperature profile according to DIN EN 12571...
If there are any shortcomings in your opinion, please do not hesitate to let us know. We shall endeavour to become even better with your help. ☺ Please add your notes here Note the details for your contact at Rieber Customer Service here: Rieber GmbH & Co. KG...
WARNING indicates a potentially hazardous situation. Failure to follow these warnings may cause serious bodily injury or even death. CAUTION indicates a potentially harmful situation. Failure to follow these warnings may cause minor bodily injury. Rieber GmbH & Co. KG...
® The plastic and stainless steel versions of the Rieber thermoport can be combined together for stacking and stored on Rieber transport and serving trolleys — for non-slip and safe transport. • CHECK HACCP – the digital system for simple, safe and transparent temperature detection –...
Make sure the appliance cannot be switched on unintentionally. Double check that the main switch is in the "OFF" position before inserting the plug in the socket. Connecting the appliance to the power supply while it is switched on can cause an accident. Rieber GmbH & Co. KG...
In addition, the operator must train the personnel and inform them of the hazards involved at regular intervals. • The operator must provide the personnel with the necessary protective equipment and make sure that they wear it. Rieber GmbH & Co. KG...
• Work on the cooling unit should only be carried out by authorised skilled personnel such as a refrigeration specialist or a member of the Rieber Customer Service. • The heating unit housing may only be opened/closed for the purpose of thorough cleaning by appropriately trained and authorised operating personnel.
Only stack matching TP appliances, otherwise there is a risk of tipping and falling. Judge the permissible stack height realistically on your own responsibility. We recommend: Stack 2 stackable TP on top of one another. ➢ Keep the door/lid closed during transport. Rieber GmbH & Co. KG...
Page 12
The responsibility for the load safety lies with the driver, the owner and the shipper. ➢ Secure the load. See transport safety in chapter ‘Information on accessories ’, page 43 Rieber GmbH & Co. KG...
Risk of scalds from contact with hot liquid food. Store food in containers and seal with a lid. ➢ Keep any combustible or explosive fluids away from heated appliances. Otherwise a fire or explosion may occur. Rieber GmbH & Co. KG...
® The plastic and stainless steel versions of the Rieber thermoport can be combined together for stacking and stored on Rieber transport and serving trolleys — for non-slip and safe transport. Chapter ‘Information on accessories ’, page 43 ff., section “MOBILE APPLIANCES” …little helpers”...
Please observe the product identification, make sure it is safely maintained The type plate on the appliance bears the legally required product data. NOTE: If the product identification is damaged or illegible, the warranty will be invalidated. Contact Rieber Service as early as possible in the event of damage.
Make yourself familiar with the instructions. User tip ➢ You can find detailed information in the company’s internal instructions. ➢ We recommend that half-yearly emergency training sessions should be carried out. Rieber GmbH & Co. KG...
We recommend: Use containers with watertight press-in lids such as ® thermoplates and Gastronorm containers from Rieber. • Transport TP in its working position. •...
Page 18
Mobile appliances may only be moved manually. Machine-aided transport, using fork lift trucks or lift trucks, is not permitted. • Do not use the heating unit of the heated TP for other purposes, for example to heat other containers or as an exposed space heater. Rieber GmbH & Co. KG...
TP 1000 KB heated with digital circulating air heater Door lock 6 Stacking runner 2 Circulating air heater 7 Mains cable, internal 3 Handle for lifting the appliance, on both sides 8 CHECK sensor (option) 4 Door 5 Stacking corners Rieber GmbH & Co. KG...
The plastic cover fits positively, small gap width. Temperature-resistant from -20 °C to +85 °C. Mobile appliance 4 corner guards. Plastic castors, wheel diameter 125 mm. 2 steering and 2 swivel castors. Stainless steel castors and antistatic tyres on request. Rieber GmbH & Co. KG...
Page 21
→ Applies to: TP actively cooled, mobile, made of stainless steel In principle all TPs can be passively cooled with cooling pellets. Cold holding means: Keeping pre-chilled food at storage temperature. ‘Preheating ’, page 50 ® precooling the thermoport Abbreviations used: See chapter 2.5 Rieber GmbH & Co. KG...
Page 22
Hygienic design H3 means: Floor, walls and cover welded tightly and gap-free. All curvatures ≥ 10 mm. 5.2.1.6 Insulating behaviour of thermoport ® Measurement according to DIN EN 12571 → See diagrams on the following pages. Rieber GmbH & Co. KG...
Page 23
Description of the Appliance # Temperature profile for hot holding (hot operating condition) Rieber GmbH & Co. KG...
Page 24
Description of the Appliance # Temperature profile for cold holding (cold operating condition) Rieber GmbH & Co. KG...
Page 25
Description of the Appliance # Temperature profile for keeping food deep-frozen (deep-freeze operating condition) ➢ Rieber GmbH & Co. KG...
85 01 20 10 Insert frame with 2 cross supports for GN 9 x 1/9 or 6 x 1/6 On request Antistatic wheels, 4 pcs., diameter 125 mm Further information: See Rieber price guide, www.rieber.de Search: Price guide Rieber GmbH & Co. KG...
Stainless steel chassis 460 x 670 x 305 mm Stainless steel with plastic corner bumpers, 2 swivel castors and 2 plastic fixed castors, diameter 125 mm, weight 7 kg Further information: See accessories on page 26, 43 Rieber GmbH & Co. KG...
W L x W x H [mm] TP 105 L heated 400 x 600 x 306 13.5 85 01 03 02 without CHECK with CHECK on request All-round external physiologically safe seal. Hygienic design H2 Rieber GmbH & Co. KG...
180 at VT -10 °C 85 01 06 16 cooled R290 85 01 06 19 cooled R290 br. TP 1000 C actively cooled 44.4 410 x 655 x 760 85 01 04 11 cooled R290 Rieber GmbH & Co. KG...
Page 34
Insert frame with 2 cross supports for GN 9 x 1/9 or 6 x 1/6 On request Antistatic wheels, 4 pcs., diameter 125 mm Further information: See Rieber price guide, www.rieber.de Search: Price guide Insert frame with 1 long support for GN Insert frame with 2 cross supports for GN Rieber GmbH &...
85 02 08 07 black with CHECK on request — TP 6000 Maxi K, mobile 766 x 790 x 1280 56.5 — without CHECK: 85 02 08 02 orange 85 02 08 12 black with CHECK on request Rieber GmbH & Co. KG...
Page 36
EURO baker dimension (option), stainless steel, to take inserts with dimensions 600 x 400 mm, 8 pairs of support rails 85 02 20 61 Stacking lock Further information: See Rieber price guide, www.rieber.de Search: Price guide Example Grid GN 2/1, stainless steel...
85 02 03 01 orange 85 02 03 28 black with CHECK: 85 02 03 55 orange 85 02 03 56 black TP 100 KB-CNS heated 370 x 645 x 308 without CHECK: 85 02 03 52 orange Rieber GmbH & Co. KG...
Page 41
Sealing plug → for TP 100 K and TP 500 K 84 19 02 02 Horizontal frame (without spring) → for TP 100 K and TP 50 K Further information: See Rieber price guide, www.rieber.de Search: Price guide Lid without cooling plate...
370 x 645 x 240 without CHECK: 85 02 02 01 orange 85 02 02 16 black with CHECK: 85 02 02 22 orange 85 02 02 23 black Accessories: See accessories on previous page Rieber GmbH & Co. KG...
Information on accessories 5.3.1 Transport safety User tip ➢ ®, When transporting the Rieber stainless steel thermoport use the transport safety device from Rieber. Highly recommended for transport by HGV. ➢ How to stack TPs. Large recessed grips facilitate handling.
User tip ® With the right accessories, thermoport is energy-saving, and the appliance can be used for a wider range of applications. ➢ Use GN containers with watertight lids from Rieber. ➢ ® Use thermoplates with watertight lids from Rieber. ➢...
C Buffet range – with rounded corners ® Rieber thermoplates • … Lid range accessories • Kitchenware containers, kitchenware lid range, Rieber kitchenware sets The Rieber price guide provides further information about a wide variety of accessories. www.rieber.de Search: Price guide Rieber GmbH & Co. KG...
Ensure that there are no protective foils on the inside or outside of the appliance. ‘Cleaning, Maintenance and Care’, page 59 # Information about packaging material ➢ Dispose of the disposable packaging with respect for the environment. Rieber GmbH & Co. KG...
Keep the TP 1000 K cool away from moisture. Only use inside buildings. ➢ Only transport food and liquids in tightly sealed containers. ➢ We recommend: Use GN containers with watertight press-in lids from Rieber and ® thermoplates Chapter ‘Information on accessories ’, page 43 ff., section gastronorm360 OPERATING SYSTEM”...
Page 49
Minimise risks during transport ➢ Transport TP with closed door/lid and mains plug disconnected. ➢ Use the Rieber transport equipment range. Chapter ‘Information on accessories ’, page 43 Risks from burning and scalding ➢ Risks of scalds to face and hands.
TP 50 KB or TP 100 KB heated ➢ Pour water in. A level of around 2 cm is sufficient. ➢ Preheat for around 20 minutes. ➢ Use GN containers with press-in lids from Rieber. Rieber GmbH & Co. KG...
For electrically-switched devices, the ACTUAL temperature is shown on the control panel. • The set temperature can be permanently stored. The set temperature can be temporarily changed. # Electrically connect the appliance ➢ Plug in the electrical connector. Rieber GmbH & Co. KG...
Page 52
# Disconnect the appliance from the power ➢ Pull out the electrical connector from the socket. If the appliance has a holder to take the electrical connector (dummy connector), insert the connector into this holder. ▌ The appliance is de-energised. Rieber GmbH & Co. KG...
By pressing both buttons at the same time for about 3 seconds, you can change the display of the temperature unit. ▌ LED is permanently lit = display in Fahrenheit °F ▌ LED is not lit = display in degrees Celsius °C Rieber GmbH & Co. KG...
# Disconnect the appliance from the power ➢ Pull out the electrical connector from the socket. If the appliance has a holder to take the electrical connector (dummy connector), insert the connector into this holder. ▌ The appliance is de-energised. Rieber GmbH & Co. KG...
➢ Place in GN containers as cold as possible; the temperature of the food should not exceed +7°C. # Always transport food closed or covered ➢ Only transport food and liquids in tightly sealed containers. Rieber GmbH & Co. KG...
Hold it at the fold-out carrying handles (1), not at the fastening clip (2) of the lid. Only carry 1 appliance at a time, unstacked. Example ➢ User tip: Use the Rieber transport equipment range. Chapter ‘Information on accessories ’, page 43 Rieber GmbH & Co. KG...
IP protection classes. Consequently there is a risk of corrosion, electrical short-circuits and other damage. These often lead to power failures, supply bottlenecks and cost-intensive production downtimes. Rieber GmbH & Co. KG...
# Would you like to retrofit CHECK HACCP? CHECK HACCP can be retrofitted at any time. ➢ Please contact Rieber customer service. # Would you like a different circulating air heater? The ‘self-regulating circulating air heater’ and ‘adjustable circulating air heater' are exchangeable.
Maintenance of refrigeration units with refrigerant R290 Refrigeration units with refrigerant R290 may only be repaired and maintained by specialist companies authorised by the manufacturer or by the Rieber company. Source: DGUV Regulation 3. Electrical systems and equipment Rieber GmbH & Co. KG...
Long-term exposure to sodium hypochlorite can cause damage to the material. It should not be used if possible. Products that are specified in the list of the German Society of Hygiene and Microbiology (DHGM) should be used. Rieber GmbH & Co. KG...
After cleaning, rub surfaces dry with a soft cloth. The cloth should be well rinsed out beforehand. User tip ➢ We recommend Rieber cleaning agent for cleaning stainless steel. ▌ It is an especially thorough yet gentle cleaner, produces a dazzling shine, and cleans and protects in one.
Page 62
Cleaning the castors incorrectly can damage them. ➢ Do not clean with a high-pressure cleaner. ➢ Clean with a hot, mild liquid detergent solution, wiping with a damp, scratch-free cloth. Then remove the cleaning residues with a well rinsed-out cloth. Rieber GmbH & Co. KG...
Clean castors Page 66 Remove fluff, clean ventilation grille. Page 67 At least 1x monthly. Page 59 Every 180 working days or Have electrical system /control checked 6 months Page 15 Inspect condition of product identification Rieber GmbH & Co. KG...
Disassembly: Open the door. Rotate the heating unit by around 10 degrees from the inside of the door and remove it. ➢ Installation: Open the door. Push the connection cable through from the inside of the door. Install the heating unit. Rieber GmbH & Co. KG...
Page 65
TP 50 KB heated CAUTION The heating rod and the seal on the container can be damaged by incorrect handling. ➢ Remove and reinstall the heating rod step by step using light rotary movements, do not lever. Rieber GmbH & Co. KG...
Installation: Open the door. Push the connection cable through from the inside of the door. Install the cooling air fan. Make sure that it is mounted in all 4 bolts. Secure the position with the slider. Rieber GmbH & Co. KG...
After cleaning, rub surfaces dry with a soft cloth. The cloth should be well rinsed out beforehand. ➢ Dry the inside of the appliance and leave the lid open until the residual moisture has dried off. Rieber GmbH & Co. KG...
Keep appliance ready for next use in dry condition ➢ Dry the inside of the appliance and leave the door / lid open until the residual moisture has dried off. Rieber GmbH & Co. KG...
➢ Have all electrical repairs carried out by an authorised electrician. Any repairs during the warranty period may only be carried out by the Rieber service department. Please contact the Rieber service department. Only spare parts that have been approved and specified by the manufacturer may be used. Certain repairs may only be carried out by the Rieber service department.
• use non-original spare parts. The "Sales and delivery terms and conditions" of Rieber GmbH & Co. KG shall apply for all warranty claims made against the manufacturer. For instance, any repairs and/or overhaul during the warranty period may only be performed by the Rieber service department, failing which any resulting claims may be voided.
Need help?
Do you have a question about the thermoport K 1000 and is the answer not in the manual?
Questions and answers