Summary of Contents for Cisco Nexus 9364E-SG2-O

  • Page 1 Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide First Published: 2025-01-20 Last Modified: 2025-04-17 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883...
  • Page 2 © 2025 Cisco Systems, Inc. All rights reserved.
  • Page 3 Installing the Chassis Safety Installation Options with Rack-Mount Kits Install a Rack Unpacking and Inspecting a New Switch Procure Tools and Equipment Switch Accessory Kit Planning How to Position the Chassis in the Rack Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 4 Requirements Specific to Standard Open Racks Requirements Specific to Perforated Cabinets Cable Management Guidelines A P P E N D I X B System Specifications Environmental Specifications Switch Dimensions Switch and Module Weights and Quantities Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 5 HVAC/HVDC Power Cables Supported by ACI-Mode and NX-OS Mode Switches Regulatory Standards Compliance Specifications A P P E N D I X C LEDs Switch Chassis LEDs Uplink Module LEDs Fan Module LEDs Power Supply LEDs Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 6 Contents Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 7 Overview, on page 1 Overview The Cisco Nexus 9364E-SG2-O switch (N9364E-SG2-O) is a 2-rack unit (RU), fixed-port, high-density switch designed to support high-density 800G fabrics for next generation leaf and spine designs. This switch contains Cisco Silicon One G200 which focuses specifically on enhanced Ethernet-based artificial intelligence/machine learning AI/ML and web-scale spine deployments.
  • Page 8 Overview Overview Figure 2: Cisco Nexus 9364E-SG2-O Rear View Ground lug location Power supply (PSU-1 and PSU-2) Fan Tray Four Fans: FT1, FT2, FT3, FT4 This switch includes these user-replaceable components: Fan modules (four) with one airflow choice: Port-side intake fan module (FAN-PI-V4) Note The switch functions normally when only one fan tray fails.
  • Page 9 Overview Overview Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 10 Overview Overview Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 11 The non-operating temperature of the switch is -40 to 158 degrees Fahrenheit (-40 to 70 degrees Celsius). Overview of Module Temperatures Built-in, automatic sensors in all switches in the Cisco Nexus 9000 Series monitor your switch at all times. Each module (supervisor, I/O, and fabric) has temperature sensors with two thresholds: Note For any Major temperature alarms from the sensors, the switch powers down in 2 minutes.
  • Page 12 • If you do not have a standby supervisor module in your switch, you have 2 minutes to decrease the temperature. For Cisco Nexus 9364E-SG2 switches, there is no standby SUP. For any major alarms, the switch powers down in 2 minutes. During this interval, the software monitors the temperature every 5 seconds and continuously sends system messages every 10 seconds, as configured.
  • Page 13 The wiring is unlikely to emit radio interference if you use a twisted-pair cable with a good distribution of grounding conductors. Copper cables should not be longer than maximum distances for the media type. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 14 Remove any paint or other non-conductive coatings on the surfaces between the mounting hardware and the enclosure or rack. Clean the surfaces and apply an antioxidant before installation. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 15 • For the N9364E-SG2-O switch, only port-side intake configuration is supported. Identify the airflow direction of each fan and power supply module by its coloring. • Red coloring indicates port-side intake airflow. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 16 • Solid-walled cabinets with a roof fan tray (bottom-to-top cooling) • Standard open four-post Telco racks Work with your cabinet vendors to determine which of their cabinets meet these requirements or see the Cisco Technical Assistance Center (TAC) for recommendations: •...
  • Page 17 Width of the front clearance area (equal to the Chassis height width of the chassis with two rack-mount 3.43 inches (8.71 cm) brackets that are attached to it). 19.0 in (48.26 cm) Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 18 Preparing the Site Cautions and Regulatory Compliance Statements for NEBS Figure 3: Clearance Required around the Chassis for Cisco Nexus N9364E-SG2-O Chassis 6.0 in. (15.24 cm) rear clearance for air exhaust 6.0 in. (15.24 cm) front Additional 6.0 in. (15.24...
  • Page 19 When you use thread-forming screws to bond equipment to its mounting metalwork, remove any paint and nonconductive coatings and clean the joining surfaces. Apply an antioxidant compound before joining the surfaces between the equipment and mounting metalwork. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 20 Pluggable optical modules comply with IEC 60825-1 Ed. 3 and 21 CFR 1040.10 and 1040.11 with or without exception for conformance with IEC 60825-1 Ed. 3 as described in Laser Notice No. 56, dated May 8, 2019. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 21 Starting the Switch, on page 26 Safety Before you install, operate, or service the switch, see the Regulatory, Compliance, and Safety Information for the Cisco Nexus 3000 and 9000 Series content for important Safety Information. Warning Statement 1071 Warning Definition...
  • Page 22 Only an instructed person or skilled person should be allowed to install, replace, or service this equipment. See statement 1089 for the definition of an instructed or skilled person. There are no serviceable parts inside. To avoid risk of electric shock, do not open. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 23 To reduce the risk of electric shock, connect the unit only to a DC power source that complies with the SELV requirements in the IEC 60950-based safety standards or the ES1 requirements in the IEC 62368-based safety standards. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 24 Statement 1005 Circuit Breaker This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective devices is rated not greater than 20A (North America), 16A (Europe), and 13A (UK). Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 25 If the rack has bonded construction, connect it to the earth ground. This action enables you to easily ground the switch and its components and to ground your electrostatic discharge (ESD) wrist strap to prevent damaging discharges when you handle ungrounded components before installing them. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 26 If you notice any discrepancies or damage, send this information to your customer service representative by email: • Invoice number of the shipper (see packing slip) • Model and serial number of the missing or damaged unit Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 27 • Antistatic mat or antistatic foam. • Grounding cable sized according to local and national installation requirements; the required length depends on the proximity of the switch to proper grounding facilities. Cisco provides a 6 AWG lug in the accessory kit.
  • Page 28 This switch does not support port-side exhaust configuration. Rack-Mount the Chassis in a 4-Post Rack This section describes how to install the Cisco N9364E-SG2-Q with kit 8K-2RU-KIT-S/8K-2RU-KIT-L. Caution If the rack is on wheels, ensure that the brakes are engaged or that the rack is otherwise stabilized.
  • Page 29 The holes that you use depend on which end of your chassis is located in the cold aisle. Rack-mount brackets Rack-mount guide M4 x 6 mm Phillips Rack-mount guide rails flat-head screw Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 30 Ground the rack if using LVDC power supplies. If using AC or HVDC power supplies, the power cord for the chassis provides grounding. Ground the rack if using AC power supplies. The power cord for AC power supplies provides the chassis grounding. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 31 2 M4 screws are used to secure the grounding lug to the chassis Grounding cable, with 0.75 in. (19 mm) of insulation that is stripped from one end, which is inserted into the grounding lug and crimped in place Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 32 • The fan and power supply modules are fully secured in their chassis slots. Procedure Step 1 For the AC power supply, do this: a) Using the recommended AC power cable for your country or region, connect one end to the AC power supply. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 33 A setup utility automatically launches the first time that you access the switch and guides you through the basic configuration. For instructions on how to configure the switch and check module connectivity, see the appropriate Cisco Nexus 9000 Series Configuration Guides. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 34 Installing the Chassis Starting the Switch Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 35 You are ready to connect the interface ports on each of the line cards to the network. Uplink Connections For a list of transceivers and cables used by this switch for uplink connections, see http://www.cisco.com/c/en/us/support/interfaces-modules/transceiver-modules/products-device-support-tables-list.html. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 36 In addition, clean connectors if they are exposed to dust or accidentally touched. Both wet and dry cleaning techniques can be effective; refer to your site's fiber-optic connection cleaning procedures. • Do not touch the ends of connectors. Touching the ends can leave fingerprints and cause other contamination. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 37 • Keep all optical connections covered when not in use. Clean them before using to prevent dust from scratching the fiber-optic cable ends. • Do not touch the ends of connectors. Touching the ends can leave fingerprints and cause other contamination. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 38 Note When you need to remove a fiber-optic transceiver, first remove the fiber-optic cable from the transceiver before you remove the transceiver from the port. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 39 Use these steps to replace the missing fan module within two minutes to avoid a shutdown. a) Remove the replacement fan module from its packing materials and place it on an antistatic surface. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 40 If the STS LED does not turn on, slide the module out of the chassis, and visually check the electrical connectors on the back side of the chassis for damage. If damaged, contact Cisco Technical Assistance for help. If undamaged, repeat the previous step to reinstall the module.
  • Page 41 Carefully slide the power supply all the way into the slot until it clicks into place. Note If the power supply does not fit into the open slot, turn the module over. Slide it into the open slot. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 42 2. Find the send (TX) and receive (RX) markings that identify the top of the SFP/SFP+ module. 3. If the SFP/SFP+ module has a bale-clasp latch, move it to the open, unlocked position. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 43 This section provides the installation, cabling, and removal instructions for the Quad Small Form-Factor Pluggable transceiver modules. Refer to the Cisco Transceiver Modules Compatibility Information for additional details on optical transceivers. The figure shows a typical 800-Gigabit OSFP (optical small form-factor pluggable) transceiver. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 44 To meet the EMI interference requirements, use the metal dust caps when the ports are not in use by optical modules. Before you begin Required Tools and Equipment • Wrist strap or other personal grounding device to prevent ESD occurrences Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 45 Press firmly on the front of the transceiver module with your thumb to fully seat the transceiver in the module’s transceiver socket (see figure Seating the QSFP Transceiver Module). Figure 6: Seating the QSFP Transceiver Module IMPORTANT: If the latch isn’t fully engaged, you might accidentally disconnect the transceiver module. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 46 Remove the dust plugs from the optical network interface cable MPO connectors and from the transceiver module optical bores. Save the dust plugs for future use. Step 2 Attach the network interface cable MPO connectors immediately to the transceiver module. Figure 7: Cabling a Transceiver Module Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 47 Grasp the pull-tab and gently pull to release the transceiver from the socket. Figure 8: Removing the QSFP Transceiver Module Step 4 Slide the transceiver out of the socket. Step 5 Place the transceiver module into an antistatic bag. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 48 Replacing Components Removing the Transceiver Module Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 49 This switch rack-mount kit contains the rack mounting brackets for 19-inch rack. To install the chassis in a 23-inch rack or an ETSI rack, you need adapter plates to accommodate the 19-inch rack mount brackets. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 50 • The roof should be perforated with at least a 20 percent open area. • The cabinet floor should be open or perforated to enhance cooling. The Cisco R Series rack conforms to these requirements. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 51 To help with cable management, allow additional space in the rack above and below the chassis to make it easier to route all of the fiber optic or copper cables through the rack. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 52 Rack Specifications Cable Management Guidelines Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 53 -1000 to 30,000 feet (-304 to 15,150 meters) * The Cisco Nexus switch functions in operating temperatures of up to 40°C at sea level. For every 300 meters (1000 ft) above sea level, the maximum temperature is reduced by 1°C. For more details on environmental requirements, see the Cisco Datasheet.
  • Page 54 This table lists the typical amount of power that the switch consumes. It also lists the maximum amount of power that you must provision for the switch and power supply for peak conditions. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 55 These sections show the power cables that you can order and use with this switch. Power Cable Specifications for AC Power Supplies Location Part Number Length Power Cord Ratin Argentina CAB-AC-16A-SG-AR 14 feet (4.26 m) 16A, 250 VAC Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 56 Power Distribution Unit (PDU) HVAC/HVDC Power Cables Supported by ACI-Mode and NX-OS Mode Switches Part Number Cord Set Description Photo CAB-HVAC-SD-0.6M HVAC 2-foot (0.6 m) cable with Saf-D-Grid and SD connectors 277V AC Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 57 Safety • CAN/CSA-C22.2 No. 60950-1 Second Edition • CAN/CSA-C22.2 No. 62368-1-19 Third Edition • ANSI/UL 60950-1 Second edition • IEC 62368-1 • EN 62368-1 • AS/NZS 62368-1 • GB4943 • UL 62368-1 Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 58 • CNS13438 Class A EMC: Immunity • EN55024 • CISPR24 • EN300386 • KN 61000-4 series RoHS The product is RoH-6 compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 59 Amber Port admin state is 'Disabled, or the SFP is absent, or both. Port admin state is 'Enabled' and SFP is present, but interface is not connected. Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 60 Status Fan tray is not receiving power Amber The fan is inserted into the system and pending to come on-line Green Fans are operating normally Flashing Amber This fan tray has failed Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 61 • Over current • Over temperature • Fan failure Flashing amber Power supply is operating but a warning condition has occurred—possibly one of these conditions: • High temperature • High power • Slow fan Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...
  • Page 62 LEDs Power Supply LEDs Cisco Nexus 9364E-SG2 (N9364E-SG2-O) NX-OS-Mode Hardware Installation Guide...

This manual is also suitable for:

N9364e-sg2-o