Download Print this page
Reznor EXUB Installation And Maintenance Manual
Reznor EXUB Installation And Maintenance Manual

Reznor EXUB Installation And Maintenance Manual

Explosion-proof electric unit heater

Advertisement

Available languages

Available languages

Quick Links

EXPLOSION-PROOF ELECTRIC UNIT HEATER INSTALLATION
AND MAINTENANCE
• Please adhere to all instructions published in this manual.
• Failure to do so may be dangerous and may void your warranty.
• The heater must not be exposed to rain or snow. This applies to installed and stored heaters.
• The heater should not be modified in any way.
• Class I, Division 1 & 2, Groups C & D
• Class II, Division 1 & 2, Groups F & G
• Temperature Code T3B (3kW/35kW = T3A)
• Class I, Zone 1 & 2, Groups IIA & IIB, T3
DO NOT DESTROY. PLEASE READ CAREFULLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
Supersedes: EXUB-IM (2023) RZ-I-EXUB-D
MODEL EXUB
 ⚠ DANGER ⚠ 
NOTE
Revision: EXUB-IM (2025) RZ-I-EXUB-F

Advertisement

loading
Need help?

Need help?

Do you have a question about the EXUB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Reznor EXUB

  • Page 1 Revision: EXUB-IM (2025) RZ-I-EXUB-F Supersedes: EXUB-IM (2023) RZ-I-EXUB-D EXPLOSION-PROOF ELECTRIC UNIT HEATER INSTALLATION AND MAINTENANCE MODEL EXUB  ⚠ DANGER ⚠  • Please adhere to all instructions published in this manual. • Failure to do so may be dangerous and may void your warranty.
  • Page 2: Model Coding

    Model Coding Factory Assigned Model Code Sequence EXUB AK7E Options Product Revision No. Model Series For minor revisions Factory Built-in Options Power Output BT1* 24VAC Control Circuit 3 kW 12 inch fan size Integral thermostat 5 kW 12 inch fan size...
  • Page 3: General Specifications

    Specifications By Model Size Model 3 to 10 kW 15 to 20 kW 25 to 35 kW Fan Diameter in. (mm) 12 (304.8) 16 (406.4) 20 (508.0) Nominal kW Air Delivery 1200 1700 2100 3000 1019 1359 2039 2888 3568 5097 Approx.
  • Page 4: Important Safety Information

    — WARNING! — Read and follow the instructions in this manual. Failure to do so may result in severe or fatal injury. IMPORTANT SAFETY INFORMATION 1. Heater is to be connected and serviced only by qualified electrician experienced with hazardous location equipment.
  • Page 5: Installation

    — WARNING! — Read and follow the instructions in this manual. Failure to do so may result in severe or fatal injury. — INSTALLATION — Mechanical Location Please follow guidelines below for optimum heating results: 1. Do not install heaters such that airflow is blocked or impeded by equipment or walls. 2.
  • Page 6: Installation - Electrical

    — WARNING! — Read and follow the instructions in this manual. Failure to do so may result in severe or fatal injury. — INSTALLATION — Electrical 1. Heater is to be connected and serviced only by qualified electrician experienced with hazardous location equipment. It is the responsibility of the installer to verify the safety and suitability of the installation.
  • Page 7: Repair And Replacement

    — WARNING! — Heater is to be serviced only by qualified electrician experienced with hazardous location equipment. Explosion/Electric Shock Hazard. Disconnect heater from power supply or fuse box before opening enclosures or servicing heater. Lock the switch in the “OFF” (open) position and/or tag the switch to prevent unexpected power application.
  • Page 8 — WARNING! — Heater is to be serviced only by qualified electrician experienced with hazardous location equipment. Explosion/Electric Shock Hazard. Disconnect heater from power supply or fuse box before opening enclosures or servicing heater. Lock the switch in the “OFF” (open) position and/or tag the switch to prevent unexpected power application.
  • Page 9 — Warning — Wiring should only be connected by qualified personnel experienced in electrical work. — Electrical Wiring — Wiring Diagrams for Standard Fan Operation Wiring Diagrams for Continuous Fan Operation...
  • Page 10: Maintenance Program

    — WARNING! — Heater should only be serviced by qualified personnel experienced in electrical work. Disconnect unit heater from power supply before starting any service or repair work. Lock the disconnect switch in the “OFF” (open) position and/or tag the switch to prevent unexpected power application. Failure to follow these procedures may result in severe or fatal injury.
  • Page 11 Limited 36-Month Warranty Reznor LLC warrants all EXUB series of explosion-proof electric heaters against defects in materials and workmanship under normal conditions of use for a period of thirty-six (36) months from date of purchase based on the following terms: 1.
  • Page 12 Company Address Phone No. For more information on Reznor HVAC products: • Contact your local Reznor representative at 1-800-695-1901 • Refer to the technical specifications, manuals, and consumer materials found at www.reznorhvac.com Specifications and illustrations subject to change without notice or incurring obligations.
  • Page 13 Révision : EXUB-IM (2025) RZ-I-EXUB-F Remplace : EXUB-IM (2023) RZ-I-EXUB-D APPAREIL DE CHAUFFAGE ÉLECTRIQUE ANTIDÉFLAGRANT INSTALLATION ET ENTRETIEN MODÈLE EXUB ⚠ DANGER ⚠ • Respecter toutes les directives de ce guide. • Tout écart peut constituer un danger et entraîner l’annulation de la garantie.
  • Page 14 Code du modèle Attribué par Séquence de code du modèle l'usine EXUB AK7E Options No. de révision du produit Série Pour des révisions mineures Puissance Option installée en usine BT1* 3 kW 24VAC Circuit de contrôle Ventilateur 12’’ (30 cm) Thermostat intégré...
  • Page 15: Spécifications Générales

    Spécifications selon le modèle Modèle 3 à 10 kW 15 à 20 kW 25 à 35 kW Diamètre du ventilateur po (mm) 12 (305) 16 (406.4) 20 (508) Puissance nominale kW Débit d’air 1200 1700 2100 3000 1019 1359 2039 2888 3568 5097...
  • Page 16 — AVERTISSEMENT! — Lire attentiveemnt toutes les directives de ce guide et s’y conformer, sous peine de risques de blessures graves ou mortelles. IMPORTANT - CONSIGNES DE SÉCURITÉ 1. Seul un électricien qualifié, possédant de l’expérience dans le domaine du matériel pour endroits dangereux, peut installer et réparer l’aérotherme.
  • Page 17: Montage

    — AVERTISSEMENT — — Lire attentivement toutes les directives de ce guide et s’y conformer, sous peine de risques de blessures graves ou mortelles. — INSTALLATION — Mécanique Emplacement Respecter les directives ci-dessous pour des résultats optimaux. Ne pas installer l’appareil trop près d’équipements ou de murs pouvant bloquer ou gêner la circulation d’air. Pour le confort des occupants, installer l’aérotherme de manière que l’air soit dirigé...
  • Page 18: Installation Électrique

    — AVERTISSEMENT — Lire attentivement toutes les directives du présent guide et s’y conformer, sous peine de risques de blessures graves ou mortelles. — INSTALLATION — Électrique Seul un électricien qualifié, possédant de l’expérience dans le domaine du matériel Exigences de câblage d'alimentation pour endroits dangereux, peut installer et réparer l’aérotherme.
  • Page 19 — AVERTISSEMENT — Seul un électricien qualifié, possédant de l’expérience dans le domaine du matériel pour endroits dangereux, peut réparer l’aérotherme. Risque d’explosion et de choc électrique. Débrancher l’aérotherme de sa source d’alimentation électrique ou en retirer le fusible de la boîte de fusibles avant d’ouvrir les boîtiers ou de réparer l’appareil. Fixer l’interrupteur à...
  • Page 20 — AVERTISSEMENT — Seul un électricien qualifié, possédant de l’expérience dans le domaine du matériel pour endroits dangereux, peut réparer l’aérotherme. Risque d’explosion et d’électrocution. Débrancher l’aérotherme de sa source d’alimentation électrique ou en retirer le fusible de la boîte de fusibles avant d’ouvrir les boîtiers ou de réparer l’appareil. Fixer l’interrupteur à OFF (circuit ouvert) ou le fixer en place afin de prévenir toute mise en marche accidentelle de l’appareil.
  • Page 21 — AVERTISSEMENT — Seul un électricien qualifié peut brancher les câbles. — Câblage électrique — Diagramme de câblage Standard Diagramme de câblage (fonctionnement du ventilateur en continu)
  • Page 22: Programme D'entretien

    — AVERTISSEMENT — Seul un électricien qualifié peut assurer l’entretien de l’aérotherme. Débrancher l’aérotherme de sa source d’alimentation avant de le réparer ou d’en faire l’entretien. Fixer l’interrup- teur à OFF (circuit ouvert) ou le fixer en place afin de prévenir toute mise en marche accidentelle de l’appareil. Tout écart peut constituer un danger et entraîner l’annulation de la garantie.
  • Page 23 Garantie limitée de 36 mois Reznor LLC garantit tous les aérothermes électriques antidéflagrants de la série EXUB, utilisés dans des conditions normales, contre tout défaut attribuable aux matériaux et à la main-d'œuvre, et ce, pendant trente-six (36) mois à partir de la date d’achat et conformément aux modalités suivantes : 1.
  • Page 24 Distributeur Entreprise Adresse Pas de téléphone Pour plus d’informations sur les produits Reznor HVAC : Pour plus d’informations sur les produits Reznor HVAC : • • Contactez votre représentant Reznor local au 1-800-695-1901 Contactez votre représentant Reznor local au 1-800-695-1901 •...