6. The receive mode fun-
ctions
properly
and
your signals are trans-
mitted,
but
you
are
unable
to make con-
tact
with
another
station.
Possible Cause
The SIMPLEX/DUPLEX Swi-
tch is in "DUP" position.
(When
desiring
SIMPLEX
mode.)
~The SIMPLEX/DUPLEX
Swi-
tch
is in "SIMP"
position.
(When
desiring
DUPLEX
mode.)
Improper
frequency split or
input/output
frequency
of
the repeater.
The main switch of the power
source was turned OFF or the
power plug was unplugged.
. The
memorized
fre-
quencies
are lost and
the display shows 5.00
(IC-25A
: 6.01) when
power switch is turned
ON.
The power failed (when using
the AC power source).
No frequency is programmed
in the
memory
channels
or
the
same
frequency
is pro-
grammed
in all the memory
channels.
The VFO/MEMORY
CHAN-
NEL
Switch
is
not
in
a
Memory Channel position.
. Те
memory
scan
operation
does
not
function when the S/S
Switch is pushed.
The
same
frequency
is pro
grammed
in
the
memory
channel
1
and
2, or
the
programmed frequency in the
memory
channel
1 is higher
than the one in the channel 2.
The
VFO/MEMORY
CHAN-
NEL
Switch
is not
in the
VFO position.
. The programmed scan
operation
does
not
function when the S/S
Switch is pushed.
. The
scan
does
not
stop even if a signal is
received.
The squelch has opened when
the scan started.
—32—
Solution
Set
the
SIMPLEX/DUPLEX
Switch to the "SIMP" position.
Set
the
SIMPLEX/DUPLEX
Switch to the "DUP" position.
Set the
proper
frequency
split
and
set
the
DUPLEX
MODE
Switch to the "NOR" ог "REV"
position, or the OFFSET Switch
to the "+" or "—"
position ac-
cording to repeater input/output
frequency.
Use
the
continuous
operating
power
source
ог
optional
memory power source.
Program the required frequencies
in the memory channels follow-
ing the instructions for "MEMO-
RY
CHANNEL
OPERATION"
on page 13.
Set the VFO/MEMORY
CHAN-
NEL
Switch
in
a
Memory
Channel position.
Program the low edge frequency
into the memory channel 1, and
the high edge frequency into the
memory channel 2.
Set the VFO/MEMORY
CHAN-
NEL Switch in the VFO position.
Engage the squelch on a nosignal
frequency, then start the scan by
pushing the S/S Switch.