Receiving Your Shipment Upon receiving your shipment, make sure that the contents are consistent with the packing list. Notify your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately with the carrier and notify your distributor at once, giving a detailed description of any damage.
Read the measurement on the multimeter, applying the reading coefficient indicated on the label on the electronic unit corresponding to the setting of the switch. A~ range: 1000 mV~/A~ 30 A~ range: 100 mV~/A~ 300 A~ range: 10 mV~/A~ 3000 A~ range: 1 mV~/A~ Multiply the reading by the coefficient.
Page 11
If you make long-duration recordings, you must deactivate automatic power OFF (see § 2.2.3). The insulation between the type B micro-USB connector and the measurement output is 1000 V CAT III or 600 V CAT IV. That makes it possible to safely connect the instrument to wattmeters with uninsulated inputs.
3.3. VARIATIONS IN THE RANGE OF USE Error in % of reading Quantity of influence Range of influence Typical Maximum Battery voltage 1.8 to 3.2 V 0.02% 0.1% Temperature 10 to 55 °C 0.15% / 10 °C 0.50% / 10 °C Relative humidity 10 to 90% RH 0.2%...
WARRANTY Your AEMC instrument is warranted to the owner for a period of two years from the date of original purchase against defects in manufacture. This limited ® warranty is given by AEMC Instruments, not by the distributor from whom it was purchased.