Advertisement

Get In Touch
Call: 01729 824108
Email: info@puravent.co.uk
Our Address
Puravent, Adremit Limited, 6 County Business Park,
Darlington Road, Northallerton, DL6 2NQ
EN
Technical manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the INFRA HT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mark INFRA HT

  • Page 1 Technical manual Get In Touch Our Address Call: 01729 824108 Puravent, Adremit Limited, 6 County Business Park, Darlington Road, Northallerton, DL6 2NQ Email: info@puravent.co.uk...
  • Page 2 Get In Touch Our Address Call: 01729 824108 Puravent, Adremit Limited, 6 County Business Park, Darlington Road, Northallerton, DL6 2NQ Email: info@puravent.co.uk...
  • Page 3 1.2 General instructions for installer, user and maintenance personnel Thank you for having chosen MARK BV products !!! We are pleased to have You among our Customers, and we do think that use of our heaters will be fully satisfactory. To keep heaters perfectly working and safe, we ask you to follow the instructions of this handbook and to have all installation and maintenance operations carried out only by skilled personnel.
  • Page 4 In case of failure and/or malfunction of the appliance, turn it off refraining from any attempt to repair or direct intervention; the eventual repair of products MARK BV should be performed only by an authorized Service Center by the Manufacturer using only original spare parts. In each case, call professionally qualified staff.
  • Page 5 - A1 apparatus, gas category II 2L3B Plate label (exemple : Infra HT 16.2 eco, G25 natural gas) Essential features of the product are listed on the packaging label on the outside of the box.
  • Page 6 3.0 Warrenty MARK BV guarantees its products, whether installed by authorized personnel, for a period of 12 months from the date of the first start-up and no later than 18 months from the date of sale. The warranty does not cover the components supplied by third parties, these are subject to the conditions of the original warranty.
  • Page 7: Technical Data

    4.0 Technical data 4.1 Series “Infra HT.2” and “Infra HT.2 eco” Model, series Infra HT.2 10.2 12.2 16.2 10+10.2 12+12.2 16+16.2 Weight, series Infra HT.2 (kg) Model, series Infra HT.2 eco 4.2 e 6.2 e 8.2 e 10.2 e 12.2 e 16.2 e...
  • Page 8 4.2 Series “Infra HT.2 PIEZO” and “Infra HT.2 eco PIEZO” Model, series Infra HT.2 PIEZO 4.2 PIEZO 6.2 PIEZO . 8.2 PIEZO . Weight, series Infra HT.2 PIEZO (kg) Model, series Infra HT.2 eco PIEZO 4.2 eco PIEZO 6.2 eco PIEZO .
  • Page 9 (mm) 1.30 1.50 1.80 2.10 2.30 note – the unit “Infra HT 10.2 DS” is NOT in production yet Get In Touch Our Address Call: 01729 824108 Puravent, Adremit Limited, 6 County Business Park, Darlington Road, Northallerton, DL6 2NQ Email: info@puravent.co.uk...
  • Page 10: Installation

    (picture 2) with different angled positions for the heater. The following figures will show you how to install all types of heaters. picture 1 – with chains series Infra HT.2 picture 2 – at wall series Infra HT.2...
  • Page 11 2 – at wall series Infra HT.2 DS The brackets provided by MARK BV allow an angle of installation variable once mounted on a wall or pillar, in order to get a better heat distribution (picture 2.1 shows supports for units type Infra HT.2 eco, Infra HT.2 eco PIEZO and Infra HT.2 DS)
  • Page 12 Infra HT 6.2 PIEZO ; Infra HT 6.2 eco PIEZO Infra HT 8.2 PIEZO ; Infra HT 8.2 eco PIEZO Infra HT 4.2 ; Infra HT 4.2 eco ; Infra HT 4.2 DS Infra HT 6.2 ; Infra HT 6.2 eco ; Infra HT 6.2 DS Infra HT 8.2 ;...
  • Page 13 • Models Infra HT.2 , Infra HT.2 eco and Infra HT.2 DS : the connection is 1/2” gas. The models Get In Touch Our Address...
  • Page 14 • Models Infra HT.2 PIEZO and Infra HT.2 eco PIEZO : the connection is 3/8” gas. The Infra HT.2 PIEZO and Infra HT.2 eco PIEZO models are equipped with valve tap, pressure stabilizer for a maximum inlet pressure of 50 mbar, and pressure intake at the nozzle.
  • Page 15 Picture 3 – Connector for electric connection Get In Touch Our Address Call: 01729 824108 Puravent, Adremit Limited, 6 County Business Park, Darlington Road, Northallerton, DL6 2NQ Email: info@puravent.co.uk...
  • Page 16: Wiring Diagram

    WIRING DIAGRAM, “SIT” control unit ON-OFF 6.0 Wiring Diagram 6.1 “SIT” control unit ON-OFF Get In Touch Our Address Call: 01729 824108 Puravent, Adremit Limited, 6 County Business Park, page 15 Darlington Road, Northallerton, DL6 2NQ Email: info@puravent.co.uk...
  • Page 17 WIRING DIAGRAM, SIT control unit H/L = TWO-STAGES 6.2 “SIT” control unit H/L = TWO-STAGES page 18 Get In Touch Our Address Call: 01729 824108 Puravent, Adremit Limited, 6 County Business Park, Darlington Road, Northallerton, DL6 2NQ Email: info@puravent.co.uk...
  • Page 18 6.3 NOTE for SIT “HIGH / LOW” gas valve = two-stages NOTE: the “HIGH / LOW ” version must be equipped with a specific switch for pressure modulator feeding, to be placed in the main electric switchboard. Modulator fed: HIGH pressure running Modulator NOT fed: LOW pressure running IMPORTANT: start-up of the heater must always take place with the modulator fed (HIGH pressure...
  • Page 19 6.5 Gas group (gas valve and flame protection) There are 3 different options: A_products with 1 burner (models Infra HT 4.2, Infra HT 6.2, Infra HT 8.2, Infra HT 10.2, Infra HT 12.2 and Infra HT 16.2) These are equipped with 1 gas valve and 1 flame protection B_products with 2 burners (models Infra HT 10+10.2, Infra HT 12+12.2 and Infra HT...
  • Page 20: Put In Operation And First Start-Up

    Check that the pressure of fuel and type of gas used comply with the provisions on the plate of the characteristics of the heater • Check the proper installation of gas valve / control flame group (only models Infra HT.2, Infra HT.2 eco and Infra HT.2 DS) •...
  • Page 21 Picture 4 – Setting of working pressure for models Infra HT.2, Infra HT.2 eco and Infra HT.2 DS with “SIT” valve 7.2 Units with manual start-up (Infra HT.2 PIEZO and Infra HT.2 eco PIEZO) For the heaters with an ignition system and electronic control flame, the start-up sequence includes...
  • Page 22: Maintenance

    • Reassemble the cap of the regulator RM and place a suitable seal picture 6 – Setting of working pressure for models Infra HT.2 PIEZO and Infra HT.2 eco PIEZO 8.0 Maintenance An appropriate use of the heaters, plus their proper and regular maintenance are essential to ensure better performance and longer working life to the heater.
  • Page 23: Nozzle Replacement

    In case you need to change the type of gas for which the heater was prepared, you should contact MARK BV to get the specific transformation kit, specifying the model of heater, serial number and the new gas. The operations must be performed by qualified personnel and in compliance with the regulations.
  • Page 24: Troubleshooting

    10.0 Trouble shooting TROUBLE POSSIBLE CAUSE SOLUTION Phase and Neutral with wrong connection Check Phase / Neutral polarity and eart con- nection A - The heater turns on, the ignition electrode continues to sparkle, The flame detection electrode is too far from Verify that the flame detection electrode is then goes to block the plates superfaces...
  • Page 25 Get In Touch Our Address Call: 01729 824108 Puravent, Adremit Limited, 6 County Business Park, Darlington Road, Northallerton, DL6 2NQ Email: info@puravent.co.uk...
  • Page 26 Get In Touch Our Address Call: 01729 824108 Puravent, Adremit Limited, 6 County Business Park, Darlington Road, Northallerton, DL6 2NQ Email: info@puravent.co.uk...
  • Page 27 DATE and STAMP OPERATION / NOTES DATE and STAMP OPERATION / NOTES DATE and STAMP OPERATION / NOTES DATE and STAMP OPERATION / NOTES DATE and STAMP OPERATION / NOTES Get In Touch Our Address Call: 01729 824108 Puravent, Adremit Limited, 6 County Business Park, Darlington Road, Northallerton, DL6 2NQ Email: info@puravent.co.uk...
  • Page 28 FAX +31 (0)598 624584 TELEFAX +49 (0)2822 97728-10 info@mark.nl info@mark.de www.mark.nl www.mark.de MARK EIRE BV MARK POLSKA Sp. z o.o COOLEA, MACROOM UL. JASNOGÓRSKA 27 CO. CORK 42-202 CZĘSTOCHOWA (POLSKA) P12 W660 (IRELAND) PHONE +48 34 3683443 PHONE +353 (0)26 45334...

This manual is also suitable for:

Infra ht.2 4.2Infra ht.2 6.2Infra ht.2 8.2Infra ht.2 10.2Infra ht.2 12.2Infra ht.2 16.2 ... Show all

Table of Contents