Drive The Digital Output - Vivotek FD8161 User Manual

Vivotek fd8161: user guide
Hide thumbs Also See for FD8161:
Table of Contents

Advertisement

zoomspeed
-5 ~ 5
autospeed
1 ~ 5
Group: eptz_c<0~(n-1)>_s<0~(m-1)> for n channel product. and m is the number of streams which
support ePTZ.
PARAMETER
VALUE
patrolseq
string[120]
patroldwelling
string[160]
i<0~19>_name
string[40]
i<0~19>_pos
<coordinate>
i<0~19>_size
<window size>

Drive the Digital Output

Note: This request requires Viewer privileges.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/dido/setdo.cgi?do1=<state>[&do2=<state>]
[&do3=<state>][&do4=<state>][&return=<return page>]
Where state is 0 or 1; "0" means inactive or normal state, while "1" means active or triggered state.
PARAMETER
VALUE
do<num>
0, 1
return
<return page>
1/7
Zoom speed
(It should be set by eCamCtrl.cgi rather than by setparam.cgi.)
1/7
Auto pan/patrol speed
(It should be set by eCamCtrl.cgi rather than by setparam.cgi.)
SECURITY
DESCRIPTION
(get/set)
1/4
The indexes of patrol points, separated by ","
1/4
The dwelling time of each patrol point, separated by ","
1/7
Name of ePTZ preset.
(It should be set by eCamCtrl.cgi rather than by
setparam.cgi.)
1/7
Left-top corner coordinate of the preset.
(It should be set by eCamCtrl.cgi rather than by
setparam.cgi.)
1/7
Width and height of the preset.
(It should be set by eCamCtrl.cgi rather than by
setparam.cgi.)
DESCRIPTION
0 – Inactive, normal state
1 – Active, triggered state
Redirect to the page <return page> after the parameter is
assigned. The <return page> can be a full URL path or relative
path according to the current path. If you omit this parameter, it
will redirect to an empty page.