J90 Lithium Ion UPS
1000VA, 1500VA, 2000VA, 3000VA Models
User & Installation Manual
www.xpcc.com | © 2025 Xtreme Power Conversion Corporation. All rights reserved. (Rev 1/21/25)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the J90-1kLiD and is the answer not in the manual?

Questions and answers

Summary of Contents for Xtreme J90-1kLiD

  • Page 1 J90 Lithium Ion UPS 1000VA, 1500VA, 2000VA, 3000VA Models User & Installation Manual www.xpcc.com | © 2025 Xtreme Power Conversion Corporation. All rights reserved. (Rev 1/21/25)
  • Page 2: Table Of Contents

    Table of Contents 1. Important Safety Warning ......................1 1-1. Transportation ........................1 1-2. Preparation......................... 1 1-3. Installation ......................... 1 1-4. Operation ........................... 1 1-5. Maintenance, service and faults .................... 1 1-6. Product Handling Guidelines ....................2 2. Installation and setup ........................3 2-1.
  • Page 3: Important Safety Warning

    1. Important Safety Warning Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly and read carefully the following instructions before installing the unit. Do not operate this unit before reading through all safety information and operating instructions carefully.
  • Page 4: Product Handling Guidelines

    high capability capacitor such as BUS-capacitors. WAIT 5 MINUTES BEFORE REMOVING THE COVER PROTECTIONS! • Only persons are adequately familiar with batteries and with the required precautionary measures may replace batteries and supervise operations. Unauthorized persons must be kept well away from the batteries. •...
  • Page 5: Installation And Setup

    2. Installation and setup NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. Please keep the original package in a safe place for future use. 2-1. Rear panel view J90-1kLiD J90i-1kLiD J90-1.5kLiD J90i-1.5kLiD...
  • Page 6: Setup The Ups

    J90-3kLiD J90i-3kLiD AC input Input fuse or Input breaker Programmable outlets or out cable RS232 communication (DB9 or RJ45 port) USB serial communication port ROO/RPO function connector Mute button Intelligent slot(SNMP/AS400. etc) External battery connector 10 CAN communication port for external battery 11 RS485 communication port for external battery 12 Breaker for light outlets 2-2.
  • Page 7: Step 6: Install Software

    of your PC. With the monitoring software installed, you can schedule UPS shutdown/start-up and monitor UPS status through PC. The UPS is equipped with intelligent slot perfect for SNMP card. When installing with SNMP card in the UPS, it will provide advanced communication and monitoring options. The UPS for 2K/3K can connect with the external battery pack, and the external battery pack need communicate with UPS or the internal battery via CAN/RS485 Step 4: Disable/Enable ROO/RPO function...
  • Page 8: Operations And Display Panel

    3. Operations and display panel The operation/display panel includes LED indicators, function keys, and an LCD interface to configure and control UPS operation. Function indicators indicators Button 3-1. Button Function Button Function Mute the alarm: Press and hold this button at least 2 seconds to ...
  • Page 9: Lcd Indicators

    3-3. LCD Indicators 1.77’’ LCD Module with 128x160 resolution 65K true color display for J90(i) models. 3-3-1. Display structure tree Header Area Outlets/Temp/Date/Time Content Area Default Main menu Sub Menu Tabs Items Remarks Page Page Page L-N voltage(V) Input Frequency(Hz) Battery status Battery voltage(V) Battery...
  • Page 10 1/2/3/4 UPS is ON Available when Reboot outlet UPS is ON Turn off when UPS on battery Discharge time limits for outlet(min) Turn on/off Mute/Unmute audible alarm Start/Stop battery manual Control Control test Clear faults Reset power statistics Current History Product type Serial number Time since startup...
  • Page 11: Status Screen

    NOTE: While the UPS is operating, the LCD will dim and display a screen saver if there is no active alarm or user interaction for two minutes. After 5 minutes, the screen will turn off. Any button press will wake it. If an alarm or fault occurs or if any button is pressed, the UPS-flow screen displays.
  • Page 12: Setting Submenu

    Frequency of input of input power. Battery Status Options Battery status Current battery state: charging, discharging, or fully-charged Battery voltage (V) Voltage of battery power Backup time (Min) Amount of back-up time remaining for battery Remaining capacity (%) Percent of capacity remaining for battery Output Status Options L-N voltage (V) Line-neutral voltage of output power...
  • Page 13 To modify UPS settings: At the main menu, select the Settings icon, and press Enter. Use the arrow buttons to move the cursor left/right and select a tab, then press Enter to display the parameter list for the selected tab. NOTE: Parameter settings are password protected, the detail see chapter 3.5.2.12 Output Parameter Options Voltage selection...
  • Page 14 Low battery time Sounds an alarm when the selected amount of time remaining for the UPS to operate in Battery mode. 2 - 30 minutes (default of 2)  Battery periodic test enable The UPS can periodically self-test the battery. Enable (default) ...
  • Page 15 Enable = The UPS will restart automatically when the input power is  restored after a complete shut down (default) Disable = The UPS will not restart automatically  Auto restart delay Length of time to elapse before an automatic restart after input power is restored. 0 - 999 seconds (default 0) ...
  • Page 16: Log Screen

    3-3-6. Setting Submenu The Control screen offers UPS-control options. To adjust the UPS controls: At the main menu, select the Control icon, and press Enter. Use the arrow buttons to move the cursor to the option, then press Enter to select the control. Control Options Turn on/off Opens the dialog to change operating modes.
  • Page 17 Alarm Messages table No. Name Code Type Description The mains voltage and Event Input abnormal frequency exceeding normal Information range. The UPS operating in battery Event Battery mode mode. The alarm will clear when Information utility power is restored. The UPS has transferred the Battery to utility Event load to the mains power from...
  • Page 18 Event Main FW update Main UPS firmware updates. Information LCD module FW Event LCD module firmware updates. update Information Communication Event Communication board firmware FW update Information updates. Pre-warning for Alarm No output from charger. charger failure Battery Battery charger voltage exceeds Alarm overcharge the acceptable voltage range...
  • Page 19: About Screen

    The inverter output voltage is Inverter soft start Fault out of the acceptable range failure when inverter soft starts. The inverter is off due to Inverter voltage Fault inverter output voltage is higher high than the normal voltage range. The inverter is off due to Inverter voltage Fault inverter output voltage is lower...
  • Page 20: Maintenance Screen

    UPS serial number. UPS FW version Version of UPS firmware on the control board. Communication FW version Version of communication firmware on the communication board. LCD module FW version Version of LCD module firmware on the display panel. Network MAC address Shows the MAC address of the SNMP card.
  • Page 21 Display Prompts and Meanings PROMPT MEANING Appears when changing important output settings (output voltage, Cannot set this online, please shut down output output frequency.). Appears when the Settings password is input correctly. Password is correct Incorrect password, please Appears when the Settings password is input incorrectly. input again Appears when the attempting to change the Setting password.
  • Page 22: Operating Mode Description

    Changing the Password The default password is 111111 (six ones). You must use the current password to change the password. At the main menu, select the Settings icon, and press Enter. At the password prompt, use the up-arrow to select the first digit, press the down-arrow to move to the next digit, repeat for each digit, then press Enter to access the settings.
  • Page 23: Faults

    3-5. Faults Fault Cause The DC bus voltage can’t reach to acceptable value within a prescribed time Bus start failure when the DC/DC soft starts. The inverter is off due to DC bus voltage is higher than the normal voltage Bus over-voltage range The inverter is off due to DC bus voltage is lower than the normal voltage...
  • Page 24: Troubleshooting

    4. Troubleshooting If the UPS system does not operate correctly, please solve the problem by using the table below. Symptom Possible cause Remedy No indication and alarm even The AC input power is not Check if input power cord though the mains is normal. connected well.
  • Page 25: Specifications

    6. Specifications J90-1kLiD J90-1.5kLiD J90-2kLiD J90-3kLiD MODEL J90i-1kLiD J90i-1.5kLiD J90i-2kLiD J90i-3kLiD CAPACITY* 1000 VA / 900 W 1500 VA / 1350 W 2000 VA / 1800 W 3000 VA / 2700 W INPUT Rated voltage 110-120 VAC or 208/220/230/240 VAC Low Line 80VAC/70VAC/60VAC/55VAC ±...
  • Page 26 Charger current 1.5A 1.5A 1/2.5/4.5/7.5A, 2.5A as default*** 4 hours recover to 4 hours recover to Recharge Time 1 hours recover to 90% capacity 90% capacity 90% capacity Battery fuse 30A/32V*2PCS 40A/58V*2PCS 40A/58V*4PCS PHYSICAL Dimension, D X W X H 477 x 438 x 44 510 x 438 x 44 580 x 438 x 44...
  • Page 27 2. Include a letter with your name, address, daytime phone number, RMA number, a copy of your original sales receipt, and a brief description of the problem. 3. Mark the RMA number on the outside of all packages. Xtreme Power cannot accept any package without the RMA number marked on the outside of the boxes.
  • Page 28 Any technical advice furnished by XPC Corporation or a XPC Corporation authorized representative before or after delivery with regard to the use or application of Xtreme Power Conversion equipment is furnished on the basis that it represents XPC Corporations best judgment under the situation and circumstances, but it is used at the recipient’s sole risk.
  • Page 29 Avertissement important concernant la sécurité Veuillez respecter tous les avertissements et toutes les consignes d'instruction strictement décrits dans ce manuel. Sauvegardez ce manuel soigneusement et lisez attentivement les instructions suivantes avant d'installer l'unité. N'utilisez pas cette unité avant d'avoir lu attentivement toutes les consignes de sécurité...
  • Page 30 • Seules les personnes qui ont une connaissance adéquate des batteries et des mesures de précaution requises peuvent remplacer les batteries et superviser le fonctionnement de l'unité. Les personnes non autorisées doivent s’éloigner des batteries. • Mise en garde - risque de choc électrique. Le circuit de batterie n'est pas isolé de la tension d'entrée.

Table of Contents