Sharp TM200 Service Manual page 23

Digital mobile phone
Hide thumbs Also See for TM200:
Table of Contents

Advertisement

2) TX test
Test burst transmission.
TX frequency of selected channels
This indicator appears
Data patterns
during burst transmission.
PCL bar
[Procedure]
1. Select a band and channel. [See 4-6-13. 1)]
2. Select PCL (Power Control Level) using PCL bar.
3. Select Data pattern.
4. Click TX ON to start burst transmission. (You can check each part in this state.)
5. Click TX OFF to end burst transmission.
* Data pattern (TSC 5) includes Training Sequence GSM 5, and other part is pseudo random data.
TM200 TX power Table (25°C, voltage: 3.7[V])
GSM900 Band
GSM900
PCL
[dBm]
5
33
6
31
7
29
8
27
9
25
10
23
11
21
12
19
13
17
14
15
15
13
16
11
17
9
18
7
19
5
3) RX test
The handset receives burst signals in this test.
RX frequency of selected channels
This indicator appears
RX Gain Setting bar
while receiving burst signals.
Sniff ON/OFF
CONFIDENTIAL
Current PCL (Read only)
TX ON/OFF button
Tolerance
+/- 2 dB
+/- 3 dB
+/- 3 dB
+/- 3 dB
+/- 3 dB
+/- 3 dB
+/- 3 dB
+/- 3 dB
+/- 3 dB
+/- 3 dB
+/- 3 dB
+/- 5 dB
+/- 5 dB
+/- 5 dB
+/- 5 dB
Current RX Gain (Read only)
RX ON/OFF button
TM200 1ADJUSTMENTS, PERFORMANCE CHECK, AND FIRMWARE UPGRADE
DCS/PCS Band
DCS/PCS
PCL
[dBm]
0
30
1
28
2
26
3
24
4
22
5
20
6
18
7
16
8
14
9
12
10
10
11
8
12
6
13
4
14
2
15
0
2 – 19
Tolerance
+/ 2 dB
+/ 3 dB
+/ 3 dB
+/ 3 dB
+/ 3 dB
+/ 3 dB
+/ 3 dB
+/ 3 dB
+/ 3 dB
+/ 4 dB
+/ 4 dB
+/ 4 dB
+/ 4 dB
+/ 4 dB
+/ 5 dB
+/ 5 dB

Advertisement

Table of Contents
loading

Table of Contents