Sharp TM200 Service Manual page 16

Digital mobile phone
Hide thumbs Also See for TM200:
Table of Contents

Advertisement

4-5-2. Default setting for the program.
• Activate the program and set defaults.
TM200
1.2.0.0
4-5-3. RF calibration (Remove SIM card)
1. Apply 4 V using a stabilized power supply and turn on the handset.
2. Start "RF calibration & check" on SPST and click "Calibration".
3. When initialization is complete, click "OK".
4. Apply 4 V using a stabilized power supply and turn on the handset.
After the handset enters Standby mode, lower the voltage to 3.7 V.
CONFIDENTIAL
1) Select
the COMport.
2) Set the GPIB No.
3)Select the test instrument.
4) Set the GPIBaddress.
5) Set the"Cable Offset" values.
For cables with connector
UKOG-1031YCZZ (1.0m)
UKOG-1032YCZZ (0.5m)
the values as follows:
(1.0m) (0.5m)
:
GSM900
0.48 0.27
:
DCS1800 0.67 0.38
:
PCS1900 0.68 0.38
In case of an attenuator
*
addition state, 6 db addition
to the value.
TM200 1ADJUSTMENTS, PERFORMANCE CHECK, AND FIRMWARE UPGRADE
2 – 12
5. Make sure the handset is on and click "OK". (Adjustment starts.)
6. Click "OK".
7. The initial screen returns.
4-5-4. RF performance check (Insert SIM card)
1. Apply 4 V using a stabilized power supply and turn on the handset.
2. Start "RF calibration & check" on SPST and click "Calibration".
3. When initialization is complete, click "OK".
4. Apply 4 V using a stabilized power supply and turn on the handset.
After the handset enters Standby mode, lower the voltage to 3.7 V.
5.Make sure the handset is in the idle mode and click "OK"..

Advertisement

Table of Contents
loading

Table of Contents