General information Use of a respirator must be part of a respiratory protection program. Three sizes S/M, M/L and L/XL. The half masks are used either as filtering devices in combination with filters from the Sundström range, or in combination with the SR 307 compressed air attachment which then serves as a breathing apparatus with continuous flow for connection to a compressed air supply.
Page 3
Unpacking the SR 100 Packing list: • Half mask • Pre-filter holder • Cleaning tissue • ID-tag • Pre-filter • Storage bag • Instruction for use OI01H-2018 SR 100 2025-01-10...
Page 4
1. Filter 1.1 In environments in which 1.3 Check that you have both gases and particles selected the right filter and occur, such as in spray that the use-by date has not painting, gas and particle been passed. (Specified on filters must be combined.
Page 5
2. Fit the filter in a mask 2.1 Fit the filter/combined 2.3 Press it into place on the filter in the mask so that the filter. arrows on the filter point towards the user’s face. Carefully check that the edge of the filter is in the internal groove of the filter mounting all around.
Page 6
3. Donning 3.1 Holding the mask in one 3.3 Holding the strap buckle, hand, grab the strap buckle pull the strap over your head and pull on the head strap and put it around your neck. until the pad is tight against the mask.
Page 7
2. Donning 2.5 Grab the pad with one 2.7 Pull the pad over your hand and the filter with the head and place it on the other. crown of the head. 2.6 Hold the mask against your face. OI01H-2018 SR 100 2025-01-10...
4. Adjusting the harness 4.1 Reach behind your neck 4.3 Pull on the free end of the and grab the free end of the strap until the respirator seats harness strap. comfortably on your face. Use your thumb and forefinger to squeeze the buckle shut.
Page 9
5. Fit check 5.1 Place the pre-filter holder 5.3 Place the palm of your to the filter. hand lightly over the hole on the pre-filter holder to make it tight. NOTE! Do not push so hard that the respirator´s shape is affected. Take a deep breath and hold your breath for about 10 s.
Page 10
6. Change the inhalation membrane 7. Change the head harness 6.1 Reach inside the 7.1 Detach the head harness respirator and gently pull out by pushing the two the inhalation membrane. connection points towards the filter attachment. 6.2 Check the edge of the 7.2 Check that the straps are inhalation valve.
Page 11
9. Change the exhalation membranes 9.1 Snap the valve covers off 9.3 Press the new the membrane seats. membranes onto the dowels. Carefully check that the membranes are in contact with the membrane seats all round. 9.2 Prise off the membranes. 9.4 Press the valve covers into place.
Page 12
9. Cleaning Sundström cleaning tissues SR 5226 are recommended for daily 9.2 Critical areas are the care. If the mask is heavily soiled, use a warm (up to +40 °C), mild exhalation membranes and soap solution and a soft brush, followed by rinsing with clean water the membrane seats which and drying in air at room temperature.
10. Maintenance schedule Before use After use Annually Visual inspection ● Functional check ● Cleaning ● Membrane change ● Head harness change ● OI01H-2018 SR 100 2025-01-10...