Intrinsically safe powered air purifying respirator (papr) (6 pages)
Summary of Contents for Sundstrom SR 500
Page 1
Operating Instruction SR 500 Powered Air-Purifying Respirator PAPR Revision: 03 OI06H-0121 SR 500 2020-10-05...
Page 2
Introduction The User Instructions for the SR 500 should be read before use. DO NOT USE the respirator until you completely read and understand the instruction manual. The SR 500 is a battery powered fan unit that, together with filters/cartridge and an approved respirator inlet covering (facepiece or headgear) is a NIOSH 42CFR84 approved powered air-purifying respirator (PAPR).
Page 3
NATIONAL STANDARDS INSTITUTE (ANSI), 11 WEST 42ND STREET, NEW YORK, N.Y. 10036, OR WITH THE REQUIREMENTS OF OSHA STANDARD 29 CFR 1910.134 AVAILABLE FROM THE US DEPARTMENT OF LABOR, OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION AND/OR OTHER PERTINENT NATIONALLY RECOGNIZED STANDARDS. NIOSH approval (USA) OI06H-0121 SR 500 2020-10-05...
Page 4
Unpacking the SR 500 Check that the equipment is complete in accordance with the packing list and has not been damaged in transit Packing list: • Fan unit SR 500 • Battery, HD • Battery charger SR 513 • Belt SR 508 •...
Page 5
3. Green LED terminals. Push the battery back into the battery compartment. Check that the battery has been pushed in as far as it will go and that its lock is operative. OI06H-0121 SR 500 2020-10-05...
Page 6
Insert the three tongues of the belt half into the slot in the fan. Begin to insert the upper tongue and then turn the belt into the fan. OI06H-0121 SR 500 2020-10-05...
3.4 Screw the adapter into onto the filter adapter. the filter mounting so far that the adapter will be in contact with the gasket. Then turn it about 1/8 turn further in order to ensure a good seal. OI06H-0121 SR 500 2020-10-05...
Page 8
3. Particulate filter 3.5 Press the filter holder onto the particulate filter. 3.6 Correctly mounted pre- filter holder with particulate filter. OI06H-0121 SR 500 2020-10-05...
Page 9
The arrows on the particulate unit are in place and are in filter must point towards the good condition. chemical cartridge. 4.2 Do not press onto the centre of the filter it might damage the filter paper. OI06H-0121 SR 500 2020-10-05...
Page 10
Press the filter holder onto the particle filter. The filters used must be of the same type, e.g. SR 532 OV/SD/CL/HC/HF+SR 510 P100/HE. When changing the filters and cartridges, both filters and cartridges must be changed. OI06H-0121 SR 500 2020-10-05...
5.2 After the button has been pressed, a programmed test will be run on the fan and the display will then light up, the sound signal will sound, and the vibrator will vibrate twice. OI06H-0121 SR 500 2020-10-05...
Page 12
The battery capacity is sufficient to allow the work to be concluded without undue haste. The work should then be interrupted, and the wearer of the equipment should leave the site. OI06H-0121 SR 500 2020-10-05...
Page 13
Note. If the bag is turned with -The flow meter held upright, the measuring tube inwards, -The ball moves freely it can be used as a storage -The bag seals well around bag. the hose. OI06H-0121 SR 500 2020-10-05...
Page 14
10 off the flow meter outlet. to 15 seconds. Switch off the fan unit and remove the flow meter. OI06H-0121 SR 500 2020-10-05...
Page 15
SR 500 can be put on. ergonomic benefits. 8.1 Take the fan unit on and 8.3 Put the belt ends in the adjust the belt so that the fan clips on each side of the belt.
Page 16
9.2 Grip the filter with one hand. Place the thumb of the other hand on the underside of the adapter at the semicircular gap. Then prise out the filter. OI06H-0121 SR 500 2020-10-05...
Page 17
9.5 Grip the gas filter with one hand. Insert a coin or some other flat object, e.g. the filter adapter, in the joint between the particulate filter and chemical cartridge. Then prise out the filter. OI06H-0121 SR 500 2020-06-15...
Page 18
If necessary, spray the product with 70 % ethanol or isopropanol sponge wetted with a solution solution for disinfection. of water and dishwashing WARNING: Never use a solvent for cleaning. detergent can be used. OI06H-0121 SR 500 2020-10-05...
Page 19
10. Cleaning/Disinfection 10.4 Clean the pre-filter 10.5 Wipe the filter adapter holders inside and out. clean. Check that the sealing ridge for the particle filter is undamaged. 10.6 Wipe the belt clean. OI06H-0121 SR 500 2020-10-05...
The following schedule shows the recommended minimum maintenance procedures required in order to ensure that the equipment is always in functional condition. 11.2 Fit the new gasket onto the flange. Check that the gasket is in place all round. OI06H-0121 SR 500 2020-10-05...
A new battery charger. Fan motor/electronic fault Send the fan away for repair Yellow rectangular battery Battery discharged Recharge the battery symbol flashes OI06H-0121 SR 500 2020-10-05...
Page 22
The fan does not run Filter clogged Check that there are filters in the fan unit and that smoothly Incorrect combination they are of the same type. No filters mounted e.g. SR 532 OV/SD/CL/HC/HF + SR 510 P100/HE OI06H-0121 SR 500 2020-10-05...