Pool Alarm - Closed Loop
Exceeds operational requirements of Model Barrier codes
Microprocessor Controlled
Monitors entry to Pool and Spa areas
Instant on or 7 second delay models available
Surface or flush mount models
15 second adult shunt
Optional A or C form relay output upon request
Built-in back-up battery capable
Must be hard wired to remote 12 volt maximum 500 mA source or to plug in power source.
Applied voltage must not exceed 15 VDC. Battery for backup only.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 289N-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for GRI 289N-1

  • Page 1 Home Products About GRI Contact GRI Where to Buy Testimonials What's New! Pool Alarm - Closed Loop Exceeds operational requirements of Model Barrier codes Microprocessor Controlled Monitors entry to Pool and Spa areas Instant on or 7 second delay models available...
  • Page 2: Closed Loop

    ALERT/POOL ALARM. The 289N-1, 289N-2, 289N-3 and 289N-4 can be operated with an on-board 9 volt battery with a 12 volt exter nally supplied DC power source, in which case the batter y will perform a back-up function should the externally supplied source fail for any reason.
  • Page 3: Installation Instructions

    If multiple openings lead to the area, the GRI DOOR ALERT/POOL ALARM can monitor all by installing CLOSED LOOP switches which are wired in series. In this way, any opening will be detected by the GRI DOOR ALERT/POOL ALARM. A single deactivation button can also be wired at each opening to utilize the pass thru feature.
  • Page 4 The 289N-1 and 289N-2 versions offer a seven second delay in which an It is suggested that some type of surge protection, such as the GRI CS-1...
  • Page 5 The battery must be replaced at this time and the cause of power failure determined and re- The GRI DOOR ALERT/POOL ALARM uses CLOSED LOOP (nor- stored. mally open) magnetic reed switches. Install the magnetic reed switch on the door according to the manufacturer’s installation...
  • Page 6 G.R.I. POOL ALARM SOFTWARE JUMPER OPTIONS (New 2008 Jumper Settings with Green Terminal G.R.I. 289 Series Pool Alarms) JP1 Jumper Positions Note that position 1 is closest to Sounder. Position 1 No Jumper, Instant On. With Jumper, 7 Second Delay. Position 2 No Jumper, 15 Second Shunt.

This manual is also suitable for:

289n-2289n-3289n-4

Table of Contents