Amphenol Charles CUBE-PM63922 Series General Description And Installation

Universal broadband enclosure

Advertisement

Quick Links

1.
GENERAL INTRODUCTION ................................................... 1
1.1. Document Purpose ............................................................... 1
1.2. Product Purpose ................................................................... 1
1.3. Product Mounting and Location ............................................ 1
2.
PRODUCT DESCRIPTION ....................................................... 2
3.
INSTALLATION ........................................................................ 4
3.1. Inspecting the Product .......................................................... 4
3.2. Following and Using Safety Precautions................................ 4
3.3. Obtaining Tools and Equipment ............................................ 4
3.4. Preparing the Installation Site ............................................... 4
3.5. Lifting the CUBE .................................................................. 5
3.6. Mounting the CUBE ............................................................. 5
3.7. CUBE Wiring and Equipment................................................ 7
3.8. Conduit Seals ....................................................................... 9
3.9. Verifying the Installation ....................................................... 9
4.
PERIODIC MAINTENANCE .................................................... 9
5.
6.
WARRANTY & CUSTOMER SERVICE ................................. 10
7.
SPECIFICATIONS ................................................................... 10
7.1. Regulatory Specifications .................................................... 10
7.2. Product Specifications ........................................................ 11

1. GENERAL INTRODUCTION

1.1. Document Purpose

This document provides general information for the CUBE-PM63922xxx family of the Charles Industries' Universal Broadband Enclosure
(CUBE) product line. Supplemental documentation that ships with the CUBE contains more detailed information about the models.
Figure 1 shows a closed front view of the enclosure.
Hereafter, the Charles Universal Broadband Enclosure CUBE-PM63922xxx will be referred to as the "CUBE."

1.2. Product Purpose

This CUBE consists of a protective enclosure for an integrated system of electronic components and equipment that can serve fiber and
copper interfaces.

1.3. Product Mounting and Location

This enclosure is suitable for outside plant-type (OSP) locations and those that may require NEC compliance. The outdoor, weather-
resistant CUBE is to be mounted on a pad. The installer connects the power, fiber and copper connections. Detailed mounting and
installation information is covered in Section 3.
©Copyright 2024 Charles Industries LLC. All rights reserved.
Availability of features and technical specifications herein are subject to change without notice.
Charles is a registered trademark of Charles Industries.
Charles Universal Broadband Enclosure
CUBE-PM63922xxx
General Description and Installation
Figure 1
-NOTE-
LT-PM63922XXX
12
th
Printing, March 15, 2024
Front View of the CUBE
Page 1 of 12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Charles CUBE-PM63922 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Amphenol Charles CUBE-PM63922 Series

  • Page 1: Table Of Contents

    LT-PM63922XXX Printing, March 15, 2024 Charles Universal Broadband Enclosure CUBE-PM63922xxx General Description and Installation GENERAL INTRODUCTION ........... 1 1.1. Document Purpose ............... 1 1.2. Product Purpose ..............1 1.3. Product Mounting and Location ..........1 PRODUCT DESCRIPTION ............2 INSTALLATION ................ 4 3.1.
  • Page 2: Product Description

    LT-PM63922XXX 2. PRODUCT DESCRIPTION The CUBE includes an equipment compartment and a battery compartment. The equipment compartment has 39RU of 23” rack spacing (front and rear). The battery compartment has a slide-out battery tray. Models within this family differ in their power systems and thermal systems.
  • Page 3 LT-PM63922XXX 11.42 12.25 12.25 PM63922JN1 PM63922LN1 6.91 12.25 PM63922MC1 PM63922UN1 Figure 3 CUBE Thermal Equipment Dimensions (in inches) Printing Page 3 of 12...
  • Page 4: Installation

    LT-PM63922XXX 3. INSTALLATION 3.1. Inspecting the Product The CUBE is shipped mounted upright on a skid. Remove the bolts, unpack the unit, and dispose of the packaging material. -INSPECTION NOTE- Visually inspect the unit for damages prior to installation. If the equipment was damaged in transit, immediately report the extent of the damage to the transportation company.
  • Page 5: Lifting The Cube

    LT-PM63922XXX 3.5. Lifting the CUBE See the supplemental documentation for CUBE weight. Charles recommends the following procedure for lifting the CUBE. SPREADER BARS Prior to lifting, remove the lifting brackets that hold SHORT SLINGS/CHAINS the mounting gasket in place. Set aside the gasket, WARNING and then replace the brackets.
  • Page 6 LT-PM63922XXX 3.6.2. Constructing a New Pad Use only concrete for new pad construction. Do not use substitute • materials since they lack the rigidity for CUBE placement. 32.0 (2) 29.0 (2) 1.5 • Observe local building practices for pad construction. Charles 1.75 (2) 1.4 recommends that the pad should extend a minimum of 8”...
  • Page 7: Cube Wiring And Equipment

    LT-PM63922XXX 3.6.4. Mounting the CUBE on a CPAD First, follow the instructions that ship with the CPAD to ensure that the CPAD is securely installed in the ground. Then proceed to mount the CUBE on the CPAD. Four customer supplied, corrosion resistant, 1/2”-13, 2” long fully threaded hex head bolts are required for mounting the CUBE to the CPAD.
  • Page 8 LT-PM63922XXX Notes: • If using Anderson connecters, then all battery strings are terminated to the bus bars on the right side. The top bus bar is the power bus for -48VDC or +24VDC cabinets. The bottom bus bar is used for the return voltage. The bus bars have covers and use 1/4”- 20 hex bolts for securing connections.
  • Page 9: Conduit Seals

    LT-PM63922XXX 3.7.6. Cable Management Kit Charles Top Hat Cable Management Kit 97-002228-A is available for field 97-002228-A installations as an option that allows cable to enter through the top of the enclosure TOP HAT (Figure 9). The 97-002230-A Top Hat cable management kit is identical, but comes factory-installed.
  • Page 10: Technical Assistance And Repair Service

    LT-PM63922XXX 5. TECHNICAL ASSISTANCE AND REPAIR SERVICE For questions on product repair or if technical assistance is required, contact Charles Technical Support. 847-806-8500 techserv@charlesindustries.com (email) http://www.charlesindustries.com/techserv.htm 6. WARRANTY & CUSTOMER SERVICE Charles Industries LLC offers a one-year warranty on the CUBE product. The Charles warranty is limited to the operation of the CUBE hardware as described in this documentation and does not cover equipment which may be integrated by a third party.
  • Page 11: Product Specifications

    LT-PM63922XXX 7.2. Product Specifications Physical Dimensions 89”Hx32”Wx32”D Color Off-white Material 0.125” Aluminum 23” Equipment Rack Space and Hole Spacing 68.25” (39 RU) rack spacing with tapped EIA #12-24 mounting holes (front and back) Battery Tray Dimensions 11.85”Hx20.88”Wx26.21”D Electrical Cable Entrance Refer to Figure 2 and Section 3.7.12 100kA AC Surge Protector Raycap MM2080-V-07-ALM...
  • Page 12 LT-PM63922XXX CUBE Part Number AC Load Center Thermal CUBE-PM63922JN1 None 4000BTU 115VAC powered HVAC CUBE-PM63922KE3 12-position 5000BTU 48VDC powered HVAC CUBE-PM63922LN1 None (2) 10000BTU 48VDC powered HVACs CUBE-PM63922LNA None (2) 10000BTU 230VAC powered HVACs CUBE-PM63922MC1 20-position 1880W 48VDC powered Heat Exchanger CUBE-PM63922UM2 12-position 10000BTU 230VAC powered HVAC...

Table of Contents