  • Page 1 DS-KD8003 Series Module Door Station User Manual...
  • Page 2: Legal Information

    ● Products described in this Document, which may include licenses obtained from third parties. Any part of the Document, including text, pictures, graphics, etc., belongs to Hikvision. No part ● of this Document may be excerpted, copied, translated, or modified in whole or in part by any means without written permission.
  • Page 3 DS-KD8003 Series Module Door Station User Manual PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY ● RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS;...
  • Page 4: Symbol Conventions

    DS-KD8003 Series Module Door Station User Manual Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Indicates a hazardous situation which, if not avoided, will or could Danger result in death or serious injury.
  • Page 5: Regulatory Information

    DS-KD8003 Series Module Door Station User Manual Regulatory Information Industry Canada ICES-003 Compliance This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: 1. this device may not cause interference, and 2.
  • Page 6: Table Of Contents

    DS-KD8003 Series Module Door Station User Manual Contents Chapter 1 Appearance ........................ 1 Chapter 2 Configure Sub Module Address ................... 8 Chapter 3 Terminal and Wiring ....................10 3.1 Cable and Transmission Distance ..................10 3.2 Terminal Description ......................10 3.3 Module Door Station Wiring ....................
  • Page 7 DS-KD8003 Series Module Door Station User Manual 6.1 Login Web Browser ......................76 6.2 Forget Password ........................76 6.3 Overview ..........................76 6.4 Person Management ......................78 6.5 Search Event ........................80 6.6 Device Management ......................81 6.7 Configuration ........................82 6.7.1 View Device Information via PC Web ................
  • Page 8 DS-KD8003 Series Module Door Station User Manual Chapter 7 Local Operation ...................... 112 7.1 Call Resident ........................112 7.2 Unlock Door ........................113...
  • Page 9: Chapter 1 Appearance

    DS-KD8003 Series Module Door Station User Manual Chapter 1 Appearance Main Unit Main Unit (with Button) Figure 1-1 Main Unit (with Button) Appearance Table 1-1 Appearance Description Description Microphone Low Illumination IR Supplement Light...
  • Page 10 DS-KD8003 Series Module Door Station User Manual Description Built-in Camera Loudspeaker Call Button Nametag TAMPER Network Interface Module-​ C onnecting Interface (output) Terminals Main Unit (without Button)
  • Page 11 DS-KD8003 Series Module Door Station User Manual Figure 1-2 Main Unit (without Button) Appearance Table 1-2 Appearance Description Description Microphone Low Illumination IR Supplement Light Built-in Camera Loudspeaker TAMPER Network Interface...
  • Page 12 DS-KD8003 Series Module Door Station User Manual Description Module-​ C onnecting Interface (Output) Terminals Note Nametag area supports insert customized name card. The suggested card size is: 58 (L) x ● 11.7(W) mm. The module connecting interface is used to connect other function module, such as nametag ●...
  • Page 13 DS-KD8003 Series Module Door Station User Manual Figure 1-3 Two-Wire Main Unit (with Button) Appearance Table 1-3 Appearance Description Description Microphone Low Illumination IR Supplement Light Built-in Camera Loudspeaker Call Button Nametag TAMPER...
  • Page 14 DS-KD8003 Series Module Door Station User Manual Description Two-Wire Interface (24 VDC Power Input) Module-​ C onnecting Interface (output) Terminals Two-Wire Main Unit (without Button) Figure 1-4 Two-Wire Main Unit (without Button) Appearance Table 1-4 Appearance Description Description Microphone Low Illumination IR Supplement Light...
  • Page 15 DS-KD8003 Series Module Door Station User Manual Description Loudspeaker TAMPER Two-Wire Interface (24 VDC Power Input) Module-​ C onnecting Interface (output) Terminals Note Nametag area supports insert customized name card. The suggested card size is: 58 (L) x ● 11.7(W) mm.
  • Page 16: Chapter 2 Configure Sub Module Address

    DS-KD8003 Series Module Door Station User Manual Chapter 2 Configure Sub Module Address You need to set the sub module address via DIP switch before installation. Steps 1. Remove the rubber cover on the rear panel of the sub module to expose the DIP switch.
  • Page 17 DS-KD8003 Series Module Door Station User Manual DIP 1 DIP 2 DIP 3 DIP 4 DIP 5 DIP 6 DIP 7 DIP 8 Module Address Module 6 Module 7 Module 8...
  • Page 18: Chapter 3 Terminal And Wiring

    DS-KD8003 Series Module Door Station User Manual Chapter 3 Terminal and Wiring 3.1 Cable and Transmission Distance Cable and transmission distance between devices should follow rules below. Table 3-1 Cable and Transmission Distance Cable Indoor Indoor Type KAD7060E KAD7060E KAD7061E...
  • Page 19 DS-KD8003 Series Module Door Station User Manual Main Unit Terminals Figure 3-1 Main Unit Terminals Table 3-2 Descriptions of Terminals and Interfaces Interface Description Door Lock Relay Output (NC) Door Lock Relay Output (NO) Common Interface Door Lock Relay Output (NC)
  • Page 20 DS-KD8003 Series Module Door Station User Manual Interface Description 12 V OUT2 PoE Network Interface(Supports IEEE 802.3af) Table 3-3 Power Supply Power Supply Door Station Power Output PoE (802.3af) DC 12V OUT1/DC 12V OUT2 6 W MAX in total DC 12 V...
  • Page 21 DS-KD8003 Series Module Door Station User Manual Interface Description Grounding 12 V IN/OUT1 The power output is 12 V, 500mA. Grounding AIN2 For the access of Door Magnetic 2 AIN1 For the access of Door Magnetic 1 AIN3 For the access of Exit Button 1...
  • Page 22 DS-KD8003 Series Module Door Station User Manual Sub Module Terminal (Except Touch-Display Module) Figure 3-3 Sub Module Terminal (Except Touch-Display Module) Table 3-6 Description Interface Description 485- Module-​ C onnecting Interface (Input) 485+ 12V IN 485- Module-​ C onnecting Interface (Output)
  • Page 23 DS-KD8003 Series Module Door Station User Manual Touch-Display Module Figure 3-4 Touch-Display Module Table 3-7 Description Interface Description 485- Module-​ C onnecting Interface (Input) 485+ 12V IN 485- Module-​ C onnecting Interface (Output) 485+ 12V OUT Grounding Interface CVSB IN...
  • Page 24: Module Door Station Wiring

    DS-KD8003 Series Module Door Station User Manual 3.3 Module Door Station Wiring 3.3.1 Door Lock Wiring Figure 3-5 Door Lock Wiring...
  • Page 25: Door Contact Wiring

    DS-KD8003 Series Module Door Station User Manual 3.3.2 Door Contact Wiring Figure 3-6 Door Contact Wiring Note AIN1 and AIN2 are defaulted to connect door contact. Door contact connected to AIN1 detects status of the lock that connected to NC1/NO1; Door contact connected to AIN2 detects the status...
  • Page 26: Exit Button Wiring

    DS-KD8003 Series Module Door Station User Manual 3.3.3 Exit Button Wiring Figure 3-7 Exit Button Wiring Note AIN3 and AIN4 are set as default for connecting exit button. Exit button connected to AIN3 opens the lock connected to NC1/NO1; Exit button connected to AIN4 controls the lock that connected to...
  • Page 27: Chapter 4 Installation

    DS-KD8003 Series Module Door Station User Manual Chapter 4 Installation Note Two-Wire Video Intercom Main Unit and Video Intercom Main Unit share the same installation methods. Therefore, the following installation procedures will take Video Intercom Main Unit as an example.
  • Page 28: One-Module Installation

    DS-KD8003 Series Module Door Station User Manual 4.1 One-Module Installation 4.1.1 One-Module Surface Mounting Before You Start Figure 4-1 Mounting Frame Note The dimension of one module mounting frame (W × H × D) is: 117 mm × 107 mm × 32.7 mm.
  • Page 29 DS-KD8003 Series Module Door Station User Manual Figure 4-2 Drill Screw Holes 3. Remove the stricker and insert the expansion sleeves into the screw holes. 4. Fix the mounting frame onto the wall with 4 expansion bolts.
  • Page 30 DS-KD8003 Series Module Door Station User Manual Figure 4-3 Fix the Mounting Frame 5. Connect the cables to the corresponding interfaces of the main unit and insert the main unit into the frame.
  • Page 31 DS-KD8003 Series Module Door Station User Manual Figure 4-4 Insert the Main Unit 6. Fix the cover onto the frame.
  • Page 32 DS-KD8003 Series Module Door Station User Manual Figure 4-5 Fix the Cover...
  • Page 33: One-Module Flush Mounting

    DS-KD8003 Series Module Door Station User Manual 4.1.2 One-Module Flush Mounting Before You Start Figure 4-6 Front and Side View of the Gang Box...
  • Page 34 DS-KD8003 Series Module Door Station User Manual Figure 4-7 Gang Box Note The dimension of one-module gang box is: 115 (W) × 134 (H) × 56 (D) mm. The dimension is for reference only. Steps 1. Drill an installation hole, and pull the cables out.
  • Page 35 DS-KD8003 Series Module Door Station User Manual Figure 4-8 Drill Installation Hole 2. Remove the plastic sheet of the cable entry. 3. Mark the gang box screw holes on the wall. 1) Route the cables through the gang box hole.
  • Page 36 DS-KD8003 Series Module Door Station User Manual Note The suggested size of the hole is 6 (diameter) × 45 (depth) mm. 5. Route the cables through the gang box hole. Insert the gang box into the installation hole. Fix the gang box with 4 expansion bolts.
  • Page 37 DS-KD8003 Series Module Door Station User Manual Figure 4-11 Remove the Mounting Ears 7. Connect the cables to the corresponding interfaces of the main unit and insert the unit into the gang box.
  • Page 38 DS-KD8003 Series Module Door Station User Manual Figure 4-12 Insert the Main Unit 8. Fix the cover and the main unit with 2 socket head cap screws by using a hexagon wrench (supplied). Figure 4-13 Fix the Cover...
  • Page 39: Two-Module Installation

    DS-KD8003 Series Module Door Station User Manual 4.2 Two-Module Installation 4.2.1 Two-Module Surface Mounting Before You Start Figure 4-14 Mounting Frame Note The dimension of two-module mounting frame (W × H × D) is: 219 mm × 107 mm × 32.7 mm.
  • Page 40 DS-KD8003 Series Module Door Station User Manual Steps 1. Paste the installation Sticker 1 onto the wall. Make sure the sticker is placed horizontally via measuring with the gradienter. 2. Drill 4 holes according to the screw holes on the sticker. The suggested size of hole is 6 (diameter) ×...
  • Page 41 DS-KD8003 Series Module Door Station User Manual Figure 4-17 Placement of Lines 6. Connect the cables. 1) Connect the lines and module-connecting line to the corresponding interfaces of the main unit, then place the main unit into the upper grid.
  • Page 42 DS-KD8003 Series Module Door Station User Manual Figure 4-18 Line Connection Effect Picture 7. Insert the modules into the frame after wiring. The main unit must be placed in the top grid. Figure 4-19 Insert the Modules 8. Use the hexagon wrench in the package to fix the cover onto the frame.
  • Page 43 DS-KD8003 Series Module Door Station User Manual Figure 4-20 Fix the Cover...
  • Page 44: Two-Module Flush Mounting

    DS-KD8003 Series Module Door Station User Manual 4.2.2 Two-Module Flush Mounting Before You Start Figure 4-21 Gang Box Note The dimension of two-module gang box is: 237 (W) × 134 (H) × 56 (D) mm. The dimension is for reference only.
  • Page 45 DS-KD8003 Series Module Door Station User Manual Note The suggested dimension of installation hole is 220 (W) × 108 (H) × 45.5 (D) mm. ● The suggested length of cables left outside is 270 mm. ● Figure 4-22 Drill the Installation Hole 2.
  • Page 46 DS-KD8003 Series Module Door Station User Manual Figure 4-23 Mark the Screw Holes 4. Drill 4 holes according to the marks on the wall, and insert the expansion sleeves into the screw holes. The suggested size of hole is 6 (diameter) × 45 (depth) mm.
  • Page 47 DS-KD8003 Series Module Door Station User Manual Figure 4-24 Fix the Gang Box 6. Fill the gap between the gang box and the wall with concrete. Remove the mounting ears with tool after concrete is dry.
  • Page 48 DS-KD8003 Series Module Door Station User Manual Figure 4-25 Remove the Mounting Ears 7. Connect cables and insert the modules. 1) Connect Cable 1 and one end of Cable 2 to the corresponding interfaces of the main unit, then insert the main unit into the upper grid.
  • Page 49 DS-KD8003 Series Module Door Station User Manual Figure 4-26 Connect Cables and Insert the Modules Note Cable 1 refers to the cables pulled out from the wall that connected to the main unit. Cable 2 refers to the module-connecting line in the accessory package.
  • Page 50: Three-Module Installation

    DS-KD8003 Series Module Door Station User Manual 4.3 Three-Module Installation 4.3.1 Three-Module Surface Installation Before You Start Figure 4-28 Mounting Frame Note The dimension of two-module mounting frame (W × H × D) is: 320.8 mm × 107 mm × 32.7 mm.
  • Page 51 DS-KD8003 Series Module Door Station User Manual Figure 4-29 Drill Screw Holes 3. Remove the sticker and insert the expansion sleeves into the screw holes. 4. Fix the mounting frame onto the wall with 4 expansion bolts. Figure 4-30 Fix the Mounting Frame...
  • Page 52 DS-KD8003 Series Module Door Station User Manual Note The mounting frame should be placed exactly as shown below for this step. The tamper plate should be at the low right of the first grid. Figure 4-31 Mounting Frame 5. Thread the module-connecting line across the thread holes of the frame. Pass the main unit...
  • Page 53 DS-KD8003 Series Module Door Station User Manual Figure 4-32 Placement of Lines 6. Connect the cables. 1) Connect the lines and module-connecting line 1 to the corresponding interfaces of the main unit, then place the main unit into the upper grid.
  • Page 54 DS-KD8003 Series Module Door Station User Manual Figure 4-33 Line Connection Effect Picture 7. Insert the modules into the frame after wiring. The main unit must be placed in the top grid.
  • Page 55 DS-KD8003 Series Module Door Station User Manual Figure 4-34 Insert the Modules into the Frame 8. Use the hexagon wrench in the package to fix the cover onto the frame.
  • Page 56 DS-KD8003 Series Module Door Station User Manual Figure 4-35 Fix the Cover...
  • Page 57: Three-Module Flush Mounting

    DS-KD8003 Series Module Door Station User Manual 4.3.2 Three-Module Flush Mounting Before You Start Figure 4-36 Gang Box...
  • Page 58 DS-KD8003 Series Module Door Station User Manual Note The dimension of one-module gang box is: 338.8(W)×134(H)×56(D) mm. ● The dimensions above are for reference only. The actual size can be slightly different from the ● theoretical dimension. Steps 1. Cave the installation hole, and pull the cable out.The suggested dimension of installation hole is 321.8(W)×108(H)×45.5(D) mm.
  • Page 59 DS-KD8003 Series Module Door Station User Manual Figure 4-38 Mark the Screw Holes 4. Drill 4 holes according to marks on the wall, and insert the expansion sleeves into the screw holes. The suggested size of hole is 6 (diameter) × 45 (depth) mm.
  • Page 60 DS-KD8003 Series Module Door Station User Manual Figure 4-40 Remove the Mounting Ears 7. Connect cables and insert the modules. 1) Connect Cable 1 and one end of Cable 2 to the corresponding interfaces of the main unit, then insert the main unit into the upper grid.
  • Page 61 DS-KD8003 Series Module Door Station User Manual Figure 4-41 Connect Cables and Insert Modules Note Cable 1 refers to the cables pulled out from the wall that connected to the main unit. Cable 2 and Cable 3 refer to the module-connecting line in the accessory package.
  • Page 62: More-Than-Three Module Installation

    DS-KD8003 Series Module Door Station User Manual Figure 4-42 Fix the Cover 4.4 More-Than-Three Module Installation 4.4.1 More-than-Three Module Surface Mounting Before You Start Figure 4-43 Mounting Frame...
  • Page 63 DS-KD8003 Series Module Door Station User Manual Note It takes two three-module mounting frames. The dimension of three-module mounting frame ● (W × H × D) is: 320.8 mm × 107 mm × 32.7 mm. The dimensions above are for reference only. The actual size can be slightly different from the ●...
  • Page 64 DS-KD8003 Series Module Door Station User Manual Figure 4-44 Drill Screw Holes 4. Remove the stickers and insert the expansion sleeves into the screw holes. 5. Thread the module-connecting line (400 mm) and grounding line across the thread hole of both...
  • Page 65 DS-KD8003 Series Module Door Station User Manual Figure 4-45 Place the Grounding Line and Module-Connecting Line Note There are 6 module-connecting lines in the package: 190 mm × 4 and 400 mm × 2. ● Take the 400 mm module-connecting line for this step.
  • Page 66 DS-KD8003 Series Module Door Station User Manual Figure 4-46 Fix the Mounting Frame 7. Pass the main unit connecting line across the thread hole to the top grid of the left frame. Thread the module-connecting line (190 mm) across the thread hole of the frame. The lines should be placed as shown below.
  • Page 67 DS-KD8003 Series Module Door Station User Manual 8. Connect the cables. 1) Connect the cables from the wall and module-connecting line 1 to the corresponding interfaces of the main unit, then place the main unit into the upper grid. 2) Connect the other end of the module-connecting line 1 to the input interface of the sub module.
  • Page 68 DS-KD8003 Series Module Door Station User Manual Figure 4-48 Line Connection Effect Picture...
  • Page 69 DS-KD8003 Series Module Door Station User Manual 9. Insert the modules into the frame after wiring. The main unit must be placed in the top grid on the left. Figure 4-49 Insert the Modules 10. Pull the grounding line out and fixed its two end to the screw on the cover.
  • Page 70 DS-KD8003 Series Module Door Station User Manual Figure 4-50 Connect the Grounding Line to the Cover 11. Use the hexagon wrench in the package to fix the cover onto the frame.
  • Page 71 DS-KD8003 Series Module Door Station User Manual Figure 4-51 Fix the Cover...
  • Page 72: More-Than-Three Module Flush Mounting

    DS-KD8003 Series Module Door Station User Manual 4.4.2 More-Than-Three Module Flush Mounting Before You Start Figure 4-52 Gang Box...
  • Page 73 DS-KD8003 Series Module Door Station User Manual Note It takes two three-module gang boxes. The dimension of the gang box is: 338.8 (W) × 134 (H) × 56 (D) mm. The dimension is for reference only. Steps 1. Drill the installation hole, and pull the cable out.The suggested dimension of installation hole is 321.8 (W) ×...
  • Page 74 DS-KD8003 Series Module Door Station User Manual Figure 4-54 Connect Two Gang Boxes 3. Select a cable entry and remove the plastic sheet. 4. Remove the plastic sheets on the side of the gang boxes (shown as 1 and 2) below:...
  • Page 75 DS-KD8003 Series Module Door Station User Manual 5. Mark the gang box screw holes on the wall. 1) Route the cables through the gang box hole. 2) Insert the gang box into the installation hole. 3) Mark the gang box screw holes' position with a marker, and take out the gang box.
  • Page 76 DS-KD8003 Series Module Door Station User Manual Figure 4-57 Fix the Gang Boxes 8. Fill the gap between the gang box and wall with concrete. Remove the mounting ears with tool after concrete is dry. Route the grounding line through the cable entries.
  • Page 77 DS-KD8003 Series Module Door Station User Manual Note The green-yellow line in the package is for grounding. 9. Connect cables and insert the modules. 1) Connect Cable 1 and one end of Cable 2 to the corresponding interfaces of the Main Unit, then place the Main Unit into the upper grid of the left gang box.
  • Page 78 DS-KD8003 Series Module Door Station User Manual Figure 4-60 Cables Connection Note Cable 2,3,5 and 6 are the module-connecting lines (190 mm) in the package. ● Cable 4 is the module-connecting line (400 mm) in the package. ● Main unit must be put in the top grid.
  • Page 79 DS-KD8003 Series Module Door Station User Manual Figure 4-61 Connect the Grounding Line to the Cover 11. Fix the cover with 2 socket head cap screws by using a hexagon wrench (supplied).
  • Page 80 DS-KD8003 Series Module Door Station User Manual Figure 4-62 Fix the Cover...
  • Page 81: Chapter 5 Activation

    Get the SADP software from the supplied disk or the official website http:// ● www.hikvision.com/en/ , and install the SADP according to the prompts. The device and the PC that runs the SADP tool should be within the same subnet.
  • Page 82: Activate Via Web Browser

    DS-KD8003 Series Module Door Station User Manual Status of the device becomes Active after successful activation. 5. Modify IP address of the device. 1) Select the device. 2) Change the device IP address to the same subnet as your computer by either modifying the IP address manually or checking Enable DHCP.
  • Page 83 DS-KD8003 Series Module Door Station User Manual Do not contain following characters in the password: the user name, 123, admin (case- ● insensitive), 4 or more continuously increasing or decreasing digits, or 4 or more consecutively repeated characters. The password strength of the device can be automatically checked. In order to increase the ●...
  • Page 84: Chapter 6 Operation Via Pc Web

    Answer the security questions. E-mail Verification 1. Export the QR code and send it to pw_recovery@hikvision.com as attachment. 2. You will receive a verification code within 5 minutes in your reserved email. 3. Enter the verification code into the verification code field to verify your identification.
  • Page 85 DS-KD8003 Series Module Door Station User Manual Figure 6-1 Overview Page Function Descriptions: Door Status Click to view the device live view. Set the volume when starting live view. Note If you adjust the volume when starting two-way audio, you may hear a repeated sounds.
  • Page 86: Person Management

    DS-KD8003 Series Module Door Station User Manual name, the card No., the time, the unit. Click Search. The results will be displayed on the right panel. Person Information You can view the added and not added information of person face, fingerprint and card.
  • Page 87: Add Fingerprint

    DS-KD8003 Series Module Door Station User Manual Figure 6-2 Add Face Picture Note The picture format should be JPG or JPEG or PNG, and the size should be less than 200 K. Add Card Click Person → +Add to enter the Add Person page.
  • Page 88: Search Event

    DS-KD8003 Series Module Door Station User Manual Figure 6-3 PIN Click Add to add the person. Or you can click Save and Continue to add the next person. Set Door Permission You can add schedule and door permission for each person.
  • Page 89: Device Management

    DS-KD8003 Series Module Door Station User Manual Figure 6-4 Search Event Enter the search conditions, including the event type, the employee ID, the name, the card No., the start time, and the end time, and click Search. The results will be displayed on the right panel.
  • Page 90: Synchronization Settings

    DS-KD8003 Series Module Door Station User Manual Synchronization Settings Click Synchronization Settings and enable Synchronize. If enabled, the current device' s settings will be synchronized to other devices. Upgrade Timing Upgrade You can choose to Enable Upgrading Device Automatically or set upgrade time so that the device will upgrade within the time.
  • Page 91: Set Time

    DS-KD8003 Series Module Door Station User Manual 6.7.2 Set Time Set the device's time zone, synchronization mode, server address, NTP port, and interval. Click System and Maintenance → System Configuration → System → System Settings → Time Settings . Figure 6-6 Time Settings Click Save to save the settings after the configuration.
  • Page 92: Change Administrator's Password

    DS-KD8003 Series Module Door Station User Manual 3. Set the DST start time, end time and bias time. 4. Click Save to save the settings. 6.7.4 Change Administrator's Password Steps 1. Click System and Maintenance → System Configuration → System → User Management →...
  • Page 93: Set I/O Parameters

    DS-KD8003 Series Module Door Station User Manual 3. You can enable Auto Binding. Note If the function is enabled, the connected secure door control unit will be automatically bound to the door station and cannot be used for other door stations.
  • Page 94 DS-KD8003 Series Module Door Station User Manual Figure 6-7 Elevator Control 2. Select Elevator No. 3. Slide to enable Elevator Control. 4. Set the elevator parameters. Elevator No. Select an elevator No. Interface Type The interface type is Network Interface by default. You need to enter the elevator controller's IP address, port No., user name, and password for communication.
  • Page 95: View Device Arming/Disarming Information

    DS-KD8003 Series Module Door Station User Manual 6.7.9 View Device Arming/Disarming Information View device arming type and arming IP address. Click System Configuration → System → User Management → Arming/Disarming Information . You can view the device arming/disarming information. Click Refresh to refresh the page.
  • Page 96 DS-KD8003 Series Module Door Station User Manual Figure 6-8 TCP/IP Settings Set the parameters and click Save to save the settings. DHCP If disable the function, you should set the IPv4 address, IPv4 subnet mask, IPv4 default gateway, preferred DNS server and the Alternate DNS server.
  • Page 97: Platform Access

    DS-KD8003 Series Module Door Station User Manual DHCP The IPv6 address is assigned by the server, router, or gateway. Manual Enter IPv6 Address, IPv6 Prefix Length, and IPv6 Default Gateway. Consult the network administrator for required information. Set Port Parameters Set the HTTP, HTTPS, RTSP and Server port parameters.
  • Page 98 DS-KD8003 Series Module Door Station User Manual Note 6 to 12 letters (a to z, A to Z) or numbers (0 to 9), case sensitive. You are recommended to use a combination of no less than 8 letters or numbers.
  • Page 99 DS-KD8003 Series Module Door Station User Manual Figure 6-9 FTP Settings 2. EnableFTP. 3. Select Server Type. 4. Enter Server IP Address and Port. 5. Configure the FTP Settings, and the user name and password are required for the server login.
  • Page 100: Set Video And Audio Parameters

    DS-KD8003 Series Module Door Station User Manual Set VoIP When the device is deployed on the LAN, penetration service can be enabled to achieve remote device management. Steps 1. Click System Configuration → Network → Device Access → VoIP .
  • Page 101 DS-KD8003 Series Module Door Station User Manual Figure 6-10 Video Settings Page Set the stream type, the video type, the resolution, the Bit Rate type, the video quality, the frame rate, the Max. bitrate, the video encoding, and I Frame Interval.
  • Page 102: Adjust Display Settings

    DS-KD8003 Series Module Door Station User Manual Figure 6-11 Audio Settings Page Set the stream type, audio encoding, input volume, output volume, speak volume and audio sampling rate. Slide to enable Unlocking Sound according to your actual need. Note You can choose the unlocking sound type as Prolonged Sound, Short Sound or Enable Voice Prompt.
  • Page 103: Osd Configuration

    DS-KD8003 Series Module Door Station User Manual Steps 1. To adjust display settings. Click System and Maintenance → System Configuration → Image → Display Settings . 2. Configure the parameters to adjust the image. Video Adjustment Set the video frame rate when performing live view remotely. After changing the video standard, you should reboot the device to take effect.
  • Page 104 DS-KD8003 Series Module Door Station User Manual 2. At Displayed Content, you can click to choose what to display. 3. You can also choose Time Format and Date Format according to your actual needs. Target Cropping Steps 1. To adjust display settings. Click System and Maintenance → System Configuration → Image →...
  • Page 105: Schedule Settings

    DS-KD8003 Series Module Door Station User Manual Note Some models support target cropping. Refer to the actual device for details. This function is mutually exclusive with some functions. After enabling target cropping, some functions will fail. Refer to the actual device for details.
  • Page 106: Event Settings

    DS-KD8003 Series Module Door Station User Manual Figure 6-13 Holiday Schedule 2) Click Add. 3) Set Start Time and End Time. 4) Select Call Type. 5) Drag mouse to set the schedule according to the actual needs. 6) Click OK.
  • Page 107 DS-KD8003 Series Module Door Station User Manual Figure 6-14 Motion Detection 2. Enable Motion. 3. Drag the process bar to adjust the Sensitivity parameter. 4. Enable Notify Surveillance Center according to your actual needs. After enabled, the alarm information is uploaded to the surveillance center when an alarm event is detected.
  • Page 108: Access Control Settings

    DS-KD8003 Series Module Door Station User Manual Figure 6-15 Linkage Settings 2. Select event. - Device Event Tampering Alarm - Door Event Door Open Timed Out (Door Contact) 3. Enable Notify Surveillance Center according to your actual needs. After enabled, the alarm information is uploaded to the surveillance center when an alarm event is detected.
  • Page 109: Privacy Settings

    DS-KD8003 Series Module Door Station User Manual Select the device corresponded door No. Door Name You can create a name for the door. Open Duration Set the door unlocking duration. If the door is not opened for the set time, the door will be locked.
  • Page 110 DS-KD8003 Series Module Door Station User Manual Delete Old Events Periodically Drag the block or enter number to set the period for event deleting. All events will be deleted according to the configured time duration. Delete Old Events by Specified Time Set a time and all events will be deleted on the configured time.
  • Page 111 DS-KD8003 Series Module Door Station User Manual Enable the function and you can present the NFC card to authenticate. In order to prevent the mobile phone from getting the data of the access control, you can disable NFC card to increase the security level of the data.
  • Page 112: Video Intercom Settings

    DS-KD8003 Series Module Door Station User Manual Figure 6-20 Add Public Password Select password type. Enter and confirm the password. Enter remarks. Select electric lock. Click Save to save the settings. 6.7.16 Video Intercom Settings Device No. Settings Steps 1. Click Video Intercom → Device No. to enter the page.
  • Page 113 DS-KD8003 Series Module Door Station User Manual Figure 6-21 Device No. Settings 2. Select the device type from the drop-down list, and set the corresponding information including Building No., Floor No., Door Station No., Community No. and Unit No. Note When you select Outer Door Station as Device Type, only Community No.
  • Page 114: Call Priority

    DS-KD8003 Series Module Door Station User Manual 4. Enable Protocol 1.0. 5. Click Save to enable the settings. Time Duration Settings Set the Max. call duration. Go to Video Intercom → Call Paramters → Call Settings . Figure 6-23 Call Settings Set the Max.
  • Page 115 DS-KD8003 Series Module Door Station User Manual Figure 6-24 Call Priority 2. Check the Call Type and set the Ring Duration of each 3 prioritys. 3. Click Save to enable the settings. Note The higher the level, the ealier the device to be called. After the call time is over, the next level of call is triggered.
  • Page 116: Maintenance And Security

    DS-KD8003 Series Module Door Station User Manual Figure 6-25 Number Settings Click +Add, and set the Room No. and SIP numbers in the pop-up dialog box. Click Save to save the settings. 6.8 Maintenance and Security 6.8.1 Upgrade and Maintenance Reboot device, restore device parameters, and upgrade device version.
  • Page 117: Restore Parameters

    DS-KD8003 Series Module Door Station User Manual Sub Device Upgrade Click System and Maintenance → Maintenance → Upgrade . Set Upgrade Settings as RS-485 Card Reader, and select a card reader. Select an upgrade type from the drop-down list. Click and select the upgrade file from your local PC.
  • Page 118: View Log Via Pc Web

    DS-KD8003 Series Module Door Station User Manual 6.8.3 View Log via PC Web You can search and view the device logs. Go to System and Maintenance → Maintenance → Log . Set the major and minor type of the log type. Set the start time and end time for searching, and click Search.
  • Page 119 DS-KD8003 Series Module Door Station User Manual Steps 1. Go to System and Maintenance → Safe → Certificate Management . 2. In the Import Key and Import Communication Certificate areas, select certificate type and upload certificate. 3. Click Import. Import CA Certificate Before You Start Prepare a CA certificate in advance.
  • Page 120: Chapter 7 Local Operation

    DS-KD8003 Series Module Door Station User Manual Chapter 7 Local Operation 7.1 Call Resident Note Make sure sub modules have connected with the main unit. ● Make sure you have configured the room No. for the device. ● Call Resident via Main Unit or Nametag Module Press the call button on the main unit or on the nametag module to call correspondent indoor stations.
  • Page 121: Unlock Door

    DS-KD8003 Series Module Door Station User Manual Note Hold ˄ or ˅ to scroll the page up or down faster. ● You can press Back button via display module to hang up. ● Call Resident via Touch-Display Module You can call corresponding resident in the two ways. They are: On the main page of the touch-display module, tap and enter the No.
  • Page 122 DS-KD8003 Series Module Door Station User Manual Note Password contains 6 digits. ● You're allowed to set 3 public passwords via iVMS-4200 client software. ● The password varies according to different rooms. ● Unlock Door by Card Note Make sure the card has been issued. You can issue the card via the door station, or via iVMS-4200 client software.