General
The ETN24-HP21-2S-FP-PROG-F is a
stylish, wall-mount thermostat
suitable for commercial and
residential applications. It offers Heat
Pump configuration for Cool & Heat
and other useful features, such as
Freeze Protection to ensure HVAC
system works well in cold
temperature.
Its 5-1-1 program, with 4 periods (Set
Cool/Set Heat) per day, is easy to use
and can provide 24-hour comfort as
well as energy savings.
Overall, the ETN24-HP21-2S-FP-
PROG-F is an attractive wall mount
thermostat with a large and easy to
read display.
Pg.1
SCI USA
4037 Charter Club Drive
Doylestown, PA 18902, USA
24VAC, wall-mount thermostat,
with Heat Pump configuration,
5-1-1 weekly program, Freeze
Protection and 2 Fan Speeds
Features
• Wall mount, 24VAC thermostat
• DIP switch selectable options:
• Heat Pump in Cool or Heat
• Internal or external sensor
• 3 minute compressor delay
• 5-1-1 programmable; 4 periods per day, each
with Set Heat and Set Cool
• Freeze Protection
• Offset – for temperature reading adjustment ±6°
• Modes – Cool, Heat, Emergency Heat, Auto,
Fan Only
• 2 fan speeds
• Auto-Fan – option
• External sensor- option
• Lock thermostat pushbuttons – option
• Temperature scale - °F
• Set points limits – 41...90 °F
• Switching between programmable or non-
programmable state
• Timer – Program or Non-program state
• IR remote control- option
• AM/PM, real time clock
Web: www.scillc.com
E-mail:
File: ETN24-HP21-2S-FP-PROG-F.PPT
Rev.1 Date: 28/4/2010

Advertisement

loading
Need help?

Need help?

Do you have a question about the ETN-24-PROG Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Systems Controls & Instruments ETN-24-PROG Series

  • Page 1 ETN24-HP21-2S-FP-PROG-F 24VAC, wall-mount thermostat, with Heat Pump configuration, 5-1-1 weekly program, Freeze Protection and 2 Fan Speeds General Features The ETN24-HP21-2S-FP-PROG-F is a • Wall mount, 24VAC thermostat stylish, wall-mount thermostat • DIP switch selectable options: suitable for commercial and •...
  • Page 2: Specifications

    ETN24-HP21-2S-FP- PROG-F Electrical Diagram Dimensions Specifications Temp. Range 50-86°F Weight 0.275 lbs 3 . 6 2 ” 0 . 8 7 ” Scale °F Color White Accuracy ±1°F Plastic PC/ABS Flammability UL94V-0 Temperature Input Thermistor 50K@77°F Accessories Part Number Description TS01/TS02 Temperature Sensor –...
  • Page 3 Pipersville, PA 18947 USA Phone: 215-766 1487 Fax: 215-766 1493 Email: info@scillc.com - www.scillc.com ETN-24-PROG Series Owner's Manual - Installation and Operating Instructions Please read this manual carefully before installation and use Index : 1. Options and accessories. 2. Installation Instructions 3.
  • Page 4 Pipersville, PA 18947 USA Phone: 215-766 1487 Fax: 215-766 1493 Email: info@scillc.com - www.scillc.com Line the back panel up against the wall or flat surface onto which it is to be mounted and drill in the appropriate screw holes. Make electrical connections as shown on enclosed electrical wiring diagram.
  • Page 5 Pipersville, PA 18947 USA Phone: 215-766 1487 Fax: 215-766 1493 Email: info@scillc.com - www.scillc.com 3.2. Connections for 2 Heat - 2 Cool - HC22 Rc - Phase for Cool Rh - Phase for Heat C - Common W1 - Heat 1 Y2 - Compressor/Cool 2 W2 - Heat 2 Y1 - Compressor/Cool 1...
  • Page 6 Pipersville, PA 18947 USA Phone: 215-766 1487 Fax: 215-766 1493 Email: info@scillc.com - www.scillc.com 4. Hardware Jumper Explanations IMPORTANT - BEFORE MAKING ANY CHANGES IN THE HARDWARE JUMPERS, DISCONNECT ELECTRICITY AT THE MAIN SWITCH. 4.1 The Hardware Jumpers are situated according to this drawing. (back of the thermostat) Jumper 3 Jumper 2 Jumper 4...
  • Page 7 Pipersville, PA 18947 USA Phone: 215-766 1487 Fax: 215-766 1493 Email: info@scillc.com - www.scillc.com 4.2 List of jumpers are description: Jumper 1 - 3 pins - External sensor operation. SEE # 4.3 Jumper 2 - 2 pins - See below table. Jumper 3 - 2 pins - See below table.
  • Page 8: Set Temperature

    Pipersville, PA 18947 USA Phone: 215-766 1487 Fax: 215-766 1493 Email: info@scillc.com - www.scillc.com 5. OPERATING MANUAL: 5.1. ON/OFF: Press ON/OFF button to activate or deactivate the thermostat. The word "ON" or "OFF" will appear in the display. 5.2 . SET TEMPERATURE Press the SET buttons (+) or (-);...
  • Page 9 Pipersville, PA 18947 USA Phone: 215-766 1487 Fax: 215-766 1493 Email: info@scillc.com - www.scillc.com Before programming your thermostat you should be familiar with the display of the unit Thermostat Display 1. Temperature digits, in normal display will show the temperature in the room. When +/- are pressed, it will flash , and the show the set point.
  • Page 10 Pipersville, PA 18947 USA Phone: 215-766 1487 Fax: 215-766 1493 Email: info@scillc.com - www.scillc.com Normal display In normal display, the display will show: - Temperature in the room. - ON or OFF. - Day of the week. - Real time clock . - Actual program that the unit is doing.
  • Page 11 Pipersville, PA 18947 USA Phone: 215-766 1487 Fax: 215-766 1493 Email: info@scillc.com - www.scillc.com Adjust Clock Adjust Clock Adjust Clock - Settings-Minutes Day of the week Settings-Hours Programming Program No. Wake Heat Temp. Cool Temp. Hour Minutes Program No. Cool Temp. Heat Temp.
  • Page 12: Override Set Temperature

    Pipersville, PA 18947 USA Phone: 215-766 1487 Fax: 215-766 1493 Email: info@scillc.com - www.scillc.com DURING THE PROGRAM THE UNIT WILL NOT CHANGE TO NORMAL DISPLAY UNTIL ALL THE PROGRAM HAS BEEN REVIEW. AT ANY TIME DURING THE PROGRAMMING YOU CAN REVIEW QUICKLY THE SETTINGS BY PRESSING THE "ON"...
  • Page 13 Pipersville, PA 18947 USA Phone: 215-766 1487 Fax: 215-766 1493 Email: info@scillc.com - www.scillc.com Press SELECT button, the HEAT and the SET TEMPERATURE will flash. Set heating with (+) or (-) buttons. Press SELECT button again or Press ON/SEND button to send information to the thermostat. The HEAT SET must always be at least 1 degree less than the COOL SET.
  • Page 14 Pipersville, PA 18947 USA Phone: 215-766 1487 Fax: 215-766 1493 Email: info@scillc.com - www.scillc.com The TIMER will blink; using the (+) or (-) buttons, Select TIMER ON or OFF. If you changed between TIMER ON or OFF, the SEND will blink. Press SEND/ON button to send the information to the thermostat. If you did not change between them, press the SELECT button to end programming.

This manual is also suitable for:

Etn24-hp21-2s-fp-prog-f