CARTRIDGE FILTER
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Pressurized air can cause the lid to separate from the tank with great force. To reduce the
risk of severe injury or death, relieve pressure by opening air relief valve before opening
filter. Before starting the pump after servicing, ensure that clamp band is correctly fastened.
See Important Warnings and Safety Instructions (page iii) and follow all instructions exactly;
including the Opening the Filter (page 4), Installing the Filter Lid and Clamp Ring (page 5), and
Start-Up Instructions (page 6).
PLUS
®
INSTALLATION AND
USER'S GUIDE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CLEAN CLEAR PLUS CCP240 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pentair CLEAN CLEAR PLUS CCP240

  • Page 1 CLEAN AND CLEAR PLUS ® CARTRIDGE FILTER INSTALLATION AND USER’S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Pressurized air can cause the lid to separate from the tank with great force. To reduce the risk of severe injury or death, relieve pressure by opening air relief valve before opening filter.
  • Page 2: Table Of Contents

    CUSTOMER SERVICE / TECHNICAL SUPPORT If you have questions about ordering Pentair Aquatic Systems replacement parts, and pool products, please contact: Customer Service and Technical Support, USA Sanford, North Carolina (8 A.M. to 4:30 P.M. ET) (8 A.M. to 4:30 P.M. — Eastern/Pacific Times)
  • Page 3: Important Warnings And Safety Instructions

    IMPORTANT WARNINGS AND SAFETY INSTRUCTIONS IMPORTANT NOTICE: This guide provides installation and operation instructions for the Clean and Clear Plus Cartridge Filter. Consult Pentair ® Water Pool and Spa, Inc. with any questions regarding this equipment. Attention Installer: This guide contains important information about the installation, operation and safe usage of this product. This information should be given to the owner and/or operator of this equipment after installation.
  • Page 4 IMPORTANT WARNINGS AND SAFETY INSTRUCTIONS THIS SYSTEM OPERATES UNDER HIGH PRESSURE When any part of the circulating system, (e.g., closure, pump, filter, valve(s), etc.), is serviced, air can enter the system and become pressurized. Pressurized air can cause the top closure to separate which can result in severe injury, death, or property damage.
  • Page 5: General Information

    GENERAL INFORMATION THIS SYSTEM OPERATES UNDER HIGH PRESSURE. When any part of the circulating system (e.g., Lock Ring, Pump, Filter, Valves, etc.) is serviced, air can enter the system and become pressurized. Pressurized air can cause the lid to separate which can result in serious injury, death, or property damage. To avoid this potential hazard, follow the instructions below.
  • Page 6: Installation

    INSTALLATION This filter must be installed by a qualified pool technician in accordance with all applicable local codes and ordinances. Improper installation could result in death or serious injury to pool users, installers, servicers, or others and may also cause damage to property. For Installation of Electrical Controls at Equipment Pad (ON/OFF Switches, Timers, Control Systems and Automation) Install all electrical controls at the equipment pad, such as ON/OFF switches, timers, control systems, etc.
  • Page 7: Installing The Manual Air Relief Valve

    Installing the Manual Air Relief Valve Figure 2 PRESSURE The High Flow manual air relief valve and pressure gauge are GAUGE included with this filter to help ensure safe operation of the equipment. Always maintain these components in good working condition. 1.
  • Page 8: Opening, Closing And Start-Up

    OPENING, CLOSING, AND START-UP The following information should be read carefully since it outlines the proper manner of care and operation for your filter system. As a result of following these instructions and taking the necessary preventative care, you can expect maximum efficiency and life from your filtration system.
  • Page 9: Installing The Filter Lid And Clamp Ring

    Installing the Filter Lid and Clamp Ring Follow these instructions exactly to prevent the lid from separating from the filter during system start-up or operation. (See Important Warnings and Safety Instructions, page ii-iii). RECOMMENDED EQUIPMENT: • Ratchet Wrench • 7/8" Socket Clamp Ring, Hand Tighten Open Position...
  • Page 10: Start-Up Instructions

    (see Cleaning the Manual Air Relief Valve, page 7). If the problem persists, call Pentair Technical Service at (800) 831-7133 for assistance. 5. After a steady stream of water appears, close the manual air relief valve by turning the valve cover assembly a quarter turn clockwise.
  • Page 11: Maintenance

    The pressure gauge is the primary indicator of how the system is operating, so correct functioning is critical. Replace the pressure gauge (Pentair P/N 190058) if it does not meet the requirements below: 1. Pressure gauge should go to zero (0) when the system is turned off and pressure is relieved.
  • Page 12: When To Clean Your Filter

    When to Clean Your Filter Proper operation can prevent avoidable repairs and maintenance. Use the pressure gauge to determine when to clean your Clean and Clear Plus Cartridge Filter for proper ® operation. The pressure reading increases as dirt is filtered from your pool. This buildup of pressure will vary due to different bathing loads, temperature, environmental conditions, etc.
  • Page 13: Acid Soaking The Filter Cartridges

    Acid Soaking the Filter Cartridges After an extended period of operation, it may be necessary to soak the cartridges in an acid solution. Acid soaking will remove algae, calcium carbonate, iron and other mineral build-ups from the cartridges. If not removed, these mineral deposits can lead to the restriction of water flow through the Clean and Clear Plus Cartridge Filter and ®...
  • Page 14: Replacing Filter Cartridges

    Replacing Filter Cartridges Filter cartridge element life will vary with pool conditions such as bather load, wind, dust, etc. You can expect an average cartridge life of three (3) years under normal conditions. To replace filter cartridges: 1. Follow Opening the Filter exactly (page 4). 2.
  • Page 15: Troubleshooting

    TROUBLESHOOTING 1. AIR ENTERING THE SYSTEM. Air entering your Clean and Clear Plus Cartridge Filter can cause lid separation. Correct any conditions in ® your filtration system that allow air to enter the system. Air entering the system can cause the lid to separate from the filter. If the below symptoms are observed, do not attempt to remove or tighten the clamping system or perform any other servicing until you have shut off pump and relieved all air and pressure in accordance with the Opening the Filter instructions (page 4).
  • Page 16: Technical Data

    TECHNICAL DATA Flow Rates PRESSURE DROP vs FLOW FLOW (gpm) Clean and Clear Plus Cartridge Filters ® Recommended Flow Rate Turnover Capacity (Gallons) Filter Area Vertical Flow Rate Model # (Sq. Ft.) Clearance* (GPM) 6 Hours 8 Hours 12 Hours CCP240 56 in.
  • Page 17: Replacement Parts

    REPLACEMENT PARTS Illustrated Parts View CLEAN AND CLEAR PLUS Cartridge Filter Installation and User’s Guide ®...
  • Page 18 Clean and Clear Plus Cartridge Filter Parts List ® Replacement Parts Item Part Item Part Description Description 190058 Pressure Gauge, with Indicator 170036 Pipe Assy. Outlet, C&C Plus High Flow Manual Air Relief Valve 190143 O-ring, Drain 98209800 (HFMARV) 190030 Drain Plug, without O-Ring 178616 Compression Spring...
  • Page 19 NOTES...
  • Page 20 Pentair Water Pool and Spa, Inc. Those names and brands may be the trademarks or regis- tered trademarks of those third parties.
  • Page 21: Important Safety Instructions

    The valve must be installed by a qualified serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances. Always disconnect power to the equipment at the circuit breaker before servicing any of the equipment. Ensure that the Pentair Water Pool and Spa ® IMPORTANT SAFETY INSTRUCTIONS disconnected circuit is locked out or properly tagged so that it cannot be switched on while you are working on the equipment.
  • Page 22: Valve Positions Overview

    FILTER OPERATES UNDER HIGH PRESSURE. When any part of the circulating system, (e.g., clamp, pump, filter, valve(s), etc.), is serviced, air can enter the system and become pressurized. Pressurized air can cause the lid to separate which can result in severe injury, death, or property damage.
  • Page 23: Valve Installation

    Valve Installation This valve is available in two models for use with sand type or diatomaceous earth (DE) type pool filters. Be sure that you have the correct model for your filter. Installing the incorrect model may cause your pump to dead head, or drain the pool when in backwash position.
  • Page 24: Technical Data

    WWW.PENTAIR.COM All Pentair trademarks and logos are owned by Pentair or one of its global affiliates. Hi-Flow™ is a trademark of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/ or other countries. Unless expressly noted, names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa, Inc.
  • Page 25 This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner/operator of this equipment. © 2014 Pentair Water Pool and Spa, Inc. All rights reserved. Rev. K • Rev. K • Rév. K 10-21-14...
  • Page 26 Failure to do so could result in death or serious injury to serviceman, pool users or others due to electrical shock. READ AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL. WARNING — Important Safety Information for Pentair Niche and Light Installation •...
  • Page 27: Section I. Installing Light Fixture During New Pool Construction

    NOTE The pool or spa electrical system can be verified with a Pool and Spa Electrical Qualification Test kit. The test kit is available from Pentair Water Pool and Spa, Inc. The electrical system inspection using this kit must be performed by trained and certified personnel.
  • Page 28: Section Ii. Replacing Light Fixture In Existing Pool

    NOTE The pool or spa electrical system can be verified with a Pool and Spa Electrical Qualification Test Kit. The test kit is available from Pentair Aquatic Systems. The electrical system inspection using this kit must be performed by trained and certified personnel.
  • Page 29: Section Iii. Replacing A Lamp Only

    WARNING Be sure to keep the special pilot screw from this underwater light. This screw mounts and electrically grounds the housing securely to the mounting ring and wet niche. Failure to use the screw provided could create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock.
  • Page 30 12* volt Models old gasket. 120 volt - 250 watt - T-4 lamp** 75 watt E. Install new gasket during reassembly of light, Pentair Water Pool 120 volt - 100 watt - T-4 lamp** 100 watt and Spa part number 79108600.
  • Page 31 H. Replace the light assembly into the niche and tighten the special pilot screw. WARNING Use only the special pilot screw provided with this underwater light. This screw mounts and electrically grounds the housing securely to the mounting ring and wet niche.
  • Page 32 Pentair Water Pool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those third parties.
  • Page 33: Manual Del Propietario

    Este manual contiene información importante sobre la instalación, operación y uso en forma segura de este producto. Esta información debe dársele al dueño(a)/operador(a) de este equipo. © 2014 Pentair Water Pool and Spa, Inc. All rights reserved. Rev. K • Rev. K • Rév. K 10-21-14...
  • Page 34 Pentair Aquatic Systems SpaBrite y AquaLight son marcas registradas de Pentair Water Pool and Spa Inc. Otras marcas registradas y nombres registrados pueden ser utilizados en este documento para hacer referencia a ya sea las entidades que poseen las marcas y nombres de sus productos. Pentair Water Pool and Spa Inc.
  • Page 35 1. NOTA La orientación requerida para todas las lámparas Pentair es con el tornillo piloto en la posición de las 12 del reloj. Esto es garantizado por la instalación correcta del nicho.
  • Page 36 El sistema eléctrico de la piscina o bañera de hidromasaje (spa) se puede verificar con un Pool and Spa Electrical Qualification Test Kit (Juego de Prueba para Calificar Piscinas y Bañeras de Hidromasaje). Estuche para efectuar Pruebas Este estuche para prueba se puede obtener en Pentair Aquatic Systems.
  • Page 37 B. Cambio del accesorio para lámpara después de cumplir con los requisitos del sistema eléctrico. ADVERTENCIA No asegurarse de que el sistema eléctrico de la piscina cumpla con los requisitos vigentes del código antes de instalar la lámpara subacuática creará un peligro eléctrico que podría resultar en la muerte o en una lesión grave de los usuarios de la piscina, instaladores, u otras personas debido a un choque eléctrico, y también podría causar daños a la propiedad.
  • Page 38 4. Desarmar los componentes de la lámpara y quitar el foco (bombilla). Quite y deseche el empaque viejo (junta). 5. Instale el empaque nuevo al armar de nuevo la luz, el número de parte de Pentair Water Pool and Spa es el 79108600.
  • Page 39 ADVERTENCIA Nunca encienda esta lámpara subacuática por más de 10 segundos a menos que esté completamente sumergida en el agua. Si la lámpara no está totalmente sumergida, el conjunto de sus componentes se pondrá sumamente caliente, lo cual podría causar quemaduras graves o la rotura de la lámpara o lente.
  • Page 40 Orientación de la abrazadera de Figura 4. Figura 5. alambre y conexión del perno. Abrazadera circular 6 mm (1/4 de pulg.) 90 grados o menos Tornillo piloto Palanca de bloqueo Posición de la Abrazadera circular Tornillo piloto El tornillo y la tuerca tienen que estar apretados a aproximadamente 90 grados del tornillo piloto en el aro de carátula, como se muestra Tornillo piloto arriba.
  • Page 41: Section I

    Prière de lire et d’observer les directives spécifiques ci-dessous. AVERTISSEMENT Avant d’installer cette lampe immergée de Pentair Water Pool and Spa, prière de lire et de suivre tous les avertissements et instructions qui l’accompagnent. Toute infraction aux consignes de sécurité et d’emploi risque de provoquer blessures graves, décès ou dégâts matériels.
  • Page 42 Toutes les installations de niche et dE luminaire doivent être faites conformément à tous les codes. Si les codes locaux exigent un joint d’étanchéité à cordon, veuillez utiliser les niches en plastique Pentair (P/N 79206600 et P/N 79206700). • Ne tenter en aucun cas de remplacer les luminaires en épissant les câbles sous l’eau ou derrière la niche.
  • Page 43: Installation De L'appareil D'éclairage Lors De La Construction D'une Nouvelle Piscine

    REMARQUE La position requise de tous les luminaires Pentair est d’avoir la vis pilote à 12 heures. Ceci est garanti par l’installation correcte de la niche. La niche immergée comporte des joints électriques appropriés et est convenablement reliée à la terre au moyen du connecteur de terre n°...
  • Page 44: Section Ii. Remplacement De L'appareil D'éclairage D'une Piscine Existante

    Le circuit électrique peut être vérifié au moyen d’un kit d’essai de qualification électrique pour piscines et bains tourbillon, kit disponible auprès de Pentair Water Pool and Spa, Inc. L’inspection du circuit au moyen du kit en question doit être réalisée par un personnel breveté et bien formé.
  • Page 45 B. Pour remplacer l’appareil d’éclairage une fois le circuit électrique installé conformément aux spécifications, procéder comme suit. AVERTISSEMENT Avant d’installer la lampe immergée, veiller à rendre le circuit électrique de la piscine conforme aux spécifications du code, car on risquerait autrement de créer un danger électrique pouvant provoquer le décès ou des dommages corporels graves pour les utilisateurs de la piscine, les installateurs ou d’autres personnes par suite d’un choc électrique, et entraîner également des dommages matériels.
  • Page 46 D. Démonter l’appareil d’éclairage et retirer l’ampoule. Ôter le vieux joint et s’en débarrasser. E. Lors de la repose de la lampe, installer un nouveau joint Pentair Water Pool and Spa référence 79108600. F. Sélectionner l'ampoule de remplacement dans le tableau 1.
  • Page 47 AVERTISSEMENT À moins qu’elle ne soit totalement immergée dans l’eau, ne jamais utiliser cette lampe pendant plus de 10 secondes, car elle atteindrait alors des températures excessives susceptibles de provoquer des brûlures graves ou de casser l’ampoule ou la lentille, et d’entraîner par là...
  • Page 48: Nomenclature Des Pièces

    à leurs produits sont la propriété de leurs détenteurs respectifs. Pentair Water Pool and Spa, Inc. déclare n'avoir aucun intérêt dans les marques et noms de produits autres que les siens.

Table of Contents