Extraoral Suction System
Instruction for Use

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DuraMax X1 and is the answer not in the manual?

Questions and answers

Summary of Contents for BEYES DuraMax X1

  • Page 1 Extraoral Suction System Instruction for Use...
  • Page 2: Table Of Contents

    • Remove the power plug from the wall outlet before cleaning the unit and when not using the unit. Turn off all controls before unplugging. • If the power cord is damaged, it must be replaced by the Beyes authorized service or similarly qualified person.
  • Page 3: How It Works

    2. HOW IT WORKS 4. SPECIFICATIONS The DuraMax Extraoral Suction System functions as an air cleaner by helping to remove airborne Model DuraMax X1 microorganisms and removing particulates from the aerosol, droplet, and air etc. The centrifugal Voltage AC110V, 60Hz fans of the unit draw air through the suction hood (Intake).
  • Page 4 After unpacking, please check all components and accessories of the unit are complete. 1. Place main body of the unit on a flat and dry ground surface. 2. Insert post into the main body. 3. Insert arm into post with green arrow on joint pointing towards the front of the unit and align arm...
  • Page 5: Operation

    6. OPERATION Control Panel Remote Control Indicator light ON/OFF 6.1 Arm Movement Time set • Joint has limited range of motion. The mechanical arm Flow + should only be bent forward vertically in the direction of the arrow on joint Flow •...
  • Page 6: Cleaning And Disinfection

    S2 Secondary Filter (Replace every 3 month) 7. CLEANING AND DISINFECTION • Wear personal proctective equipment • Unplug power cord 7.1 Suction hood 1. Open filter compartment door Always disinfect the suction hood between patients by wiping it completely with an appropriate 2.
  • Page 7: Scope Of Warranty

    9. Beyes Limited Warranty Statement 9.1 SCOPE OF WARRANTY BEYES Dental Canada Inc. warrants to the original retail purchaser that it will be at BEYES option to repair or replace components of the dental products manufactured by BEYES (except for components not warranted under 'Exclusions') that are defective in material or workmanship under normal use and service.
  • Page 8: Warranty

    (12) Products that would otherwise by covered under Sections 1 and 2 of this limited warranty, but are acquired: (i) from a person or entity that is not BEYES or one of its authorized dealers; or (ii) from a BEYES dealer that is not authorized to sell the product at issue in the geographic territory where the...
  • Page 9 The statement of the Guide & Manufacturer— Electromagnetic Immunity Power 3 A/m 3 A/m Power frequency magnetic field should have Frequency PFMF features in a typical place of the typical DuraMax Extraoral Suction System expected that it should be used in the below electromagnetic Magnetic Field commercial or hospital environment.
  • Page 10 Note 1: At 80MHz and 800MHz frequencies, the higher frequency band formula is used. 11. DURAMAX FILTER REPLACEMENT LOG Note 2: These guidelines may not be suitable for all situations. Electromagnetic propagation is affected by absorption and reflection from buildings, objects and the human body. Model: ________________________ The field strengths of fixed transmitters, such as: base stations for wireless(cellular/cordless) phones and terrestrial mobile radios, amateur radios, AM and FM radio broadcasts, and...
  • Page 11 S1 Filter - PPS102 S1 Filter - PPS102 Replace Monthly Replace Monthly Replacement Date Replace by Date Replaced By Replacement Date Replace by Date Replaced By (DD-MM-YY) (DD-MM-YY) (DD-MM-YY) (DD-MM-YY)
  • Page 12 S2 Filter - PPS103 S2 Filter - PPS103 Replace every 3 month Replace every 3 month Replacement Date Replace by Date Replaced By Replacement Date Replace by Date Replaced By (DD-MM-YY) (DD-MM-YY) (DD-MM-YY) (DD-MM-YY)
  • Page 13 S3 Filter - PPS104 S3 Filter - PPS104 Replace every 3 month Replace every 3 month Replacement Date Replace by Date Replaced By Replacement Date Replace by Date Replaced By (DD-MM-YY) (DD-MM-YY) (DD-MM-YY) (DD-MM-YY)
  • Page 14 S4 Filter - PPS105 S4 Filter - PPS105 Replace every 6 month Replace every 6 month Replacement Date Replace by Date Replaced By Replacement Date Replace by Date Replaced By (DD-MM-YY) (DD-MM-YY) (DD-MM-YY) (DD-MM-YY)
  • Page 15 Beyes Dental Canada Inc. 23-595 Middlefield Rd Lotus NL B.V. Scarborough, ON M1V 3S2 Koningin Julianaplein 10, Ie Verd, Canada 2595AA, The Hague, Tel: 1-855-603-1888 Netherlands Email: info@beyes.ca Printed in Canada Website: www.beyes.ca File #: ENI026 Rev3/09.17.24...