ZIEHL STW1K Operating Manual

Ac current sensing relay, or circuit 1-8 of transducers

Advertisement

Quick Links

Temperature Relays and MINIKA®
Operating Manual STW1K
For more information and help about this product please scan the
choose the following link:
Operating manual, Quick guide, Datasheet, Connection diagram, CAD Data
Firmwareupdates, FAQ, Videos about installation and settings, Certificates
- AC Current Sensing Relay, OR circuit 1-8 of transducers
STW1K
10630-0721-00
Mains Monitoring
Digital Panelmeters MINIPAN®
STW1K
Switching Relays and Controls
Page 1 / 8
ZIEHL industrie – elektronik GmbH + Co KG
Daimlerstr.13, 74523 Schwäbisch Hall, Germany
+ 49 791 504-0,
info@ziehl.de,
Measuring Transducers
Grid- and Plant Protection
updated: 2024-10-28 / sm
QR-Code
or
www.ziehl.deAA
www.ziehl.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STW1K and is the answer not in the manual?

Questions and answers

Summary of Contents for ZIEHL STW1K

  • Page 1 ZIEHL industrie – elektronik GmbH + Co KG Daimlerstr.13, 74523 Schwäbisch Hall, Germany + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA® Mains Monitoring Digital Panelmeters MINIPAN® Switching Relays and Controls Measuring Transducers Grid- and Plant Protection updated: 2024-10-28 / sm...
  • Page 2: Table Of Contents

    2 Application and short description STW1K current relay is an automatic starting device in OR circuit with 8 inputs. If a current > 1 A flows through at least one connected transducer, the integrated relay (1co) is activated. If the currents through all transformers are 0, the relay switches off with a delay of about 10 s to allow for the necessary timeout, e.g.
  • Page 3: Connecting Diagram

    5 Detailed description The STW1K current relay operates in an OR circuit and detects whether or not current is flowing in one of up to 8 monitored wires. The relay is activated when the current flowing through the current transducer exceeds a value of approximately 1 A.
  • Page 4: Important Information

    • connecting wires refer to the connection plan to prevent miss-operation and malfunction. A circuit-breaker or switch must be situated within easy reach of the unit and fused. Installation excess current protection should be ≤ 10 A. STW1K 10630-0721-00 Page 4 / 8...
  • Page 5: Start-Up

    • check that the current transformer is properly connected. The consumer must be turned on. Verify that only one conductor is routed through the transmitter. STW1K 10630-0721-00 Page 5 / 8 www.ziehl.de...
  • Page 6: 10 Technical Data

    Failure rate (FIT) Tu = 40 °C Tu = 60°C Tu = 80°C Tu = Tref (component not in operation) 555 FIT 1147 FIT 2596 FIT 100 (205) years 99 years 43 years STW1K 10630-0721-00 Page 6 / 8 www.ziehl.de...
  • Page 7 IP40 IK-Code IK06 (1 J impact energy) Mounting Snap mounting on 35 mm standard rail EN60715 or M4 screws (additional bar not included) Mounting position Weight app. 95 g Subject to technical changes STW1K 10630-0721-00 Page 7 / 8 www.ziehl.de...
  • Page 8: 11 Housing Type K

    12 Disposal Disposal should be carried out properly and in an environmentally friendly manner in accordance with legal provisions. ZIEHL is registered with the EAR Foundation under WEEE no .: DE 49 698 543. STW1K 10630-0721-00 Page 8 / 8...