Follow the basic plumbing diagram as shown. Additional installation advice is available online. (See page 1)
l
Figure 1
Water Connections to Heat Pump
Connections to site plumbing are made via PVC solvent cement to the female slip socket of the plumbing
l
unions.
Additional installation advice is available online. (See page 1)
l
Do not use glue on the threaded portion of the equipment's unions. A glued-in-place union will prevent the
l
equipment from being properly winterized.
In-Line Chlorine Feeders
Place in-line chlorinators downstream from the heat pump and as low in elevation as possible.
If an erosion type feeder is used, it is recommended that a Hartford Loop be installed to protect internal heat
l
pump components.
A Hartford Loop is not required when using a Salt Chlorine Generator.
l
Avoid storing corrosive chemicals near the heat pump to minimize potential damage to the exterior of the heat
l
pump.
Heat Pump with Erosion Tablet Feeder and Hartford Loop
Page - 10