Table 1-6. System Messages
System Message
ROM bad checksum = address
Sector not found
Seek error
Seek operation failed
Shutdown failure
Spare bank enabled
The amount of system memory
has changed
Time-of-day clock stopped
Time-of-day not set – please
run SETUP program
Timer chip counter 2 failed
Unexpected interrupt in
protected mode
Unsupported CPU combination
Unsupported CPU stepping
detected
Unsupported DIMM detected in
the RAID DIMM slot!
Utility partition not
available
Write fault
Write fault on selected drive
BIOS Update Attempt Failed
Warning! No micro code update
loaded for processor n
38
About Your System
Corrective Action
Expansion card improperly installed or
faulty
Defective sectors on diskette or hard-disk
drive
Defective sectors on diskette or hard-disk
drive
Faulty diskette or hard-disk drive
Defective system board
DIMM sparing has been enabled
DIMMs have been added or removed
Defective battery or faulty chip
Incorrect Time or Date settings or
defective system battery
Defective system board
Improperly seated DIMMs or faulty
keyboard/mouse controller chip
The installed processors cannot be
installed at the same time.
Invalid processor stepping is detected
DIMM installed in RAID DIMM slot is
not supported.
Utility partition is not available on the
hard disk
Faulty diskette or hard-disk drive
BIOS remote update failed
Micro code update failed