Table 1-5. LCD Status Messages
Code
Test
E2112 Mem Spare
Crd # DIMM
##
E2113 Mem Mirror
Crd # DIMM
## & ##
E2118 Fatal NB
Mem CRC
E2119 Fatal SB
Mem CRC
I1910 Intrusion
32
About Your System
Causes
The system BIOS has
spared the memory
because it has determined
that the memory had too
many errors. "## & ##"
represents the DIMM pair
implicated by the BIOS. If
no memory card is present,
the "Crd #" string is left
out of the message.
The system BIOS has
disabled memory mirroring
because it has determined
that one half of the mirror
has had too many errors.
"## & ##" represents the
DIMM pair implicated by
the BIOS. If no memory
card is present, the "Crd #"
string is left out of the
message.
One of the connections in
the Fully Buffered DIMM
(FBDIMM) memory
subsystem link on the
Northbound side has
failed.
One of the connections in
the FBDIMM memory
subsystem link on the
Southbound side has
failed.
System cover has been
removed.
Corrective Actions
See "Troubleshooting
System Memory" on
page 139.
See "Troubleshooting
System Memory" on
page 139.
See "Troubleshooting
System Memory" on
page 139.
See "Troubleshooting
System Memory" on
page 139.