Dell PowerEdge XK946 Hardware Owner's Manual page 31

Dell rack server hardware owner's manual
Table of Contents

Advertisement

Table 1-5. LCD Status Messages
Code
Test
E201F DRAC Config
E2020 CPU Config
E2021 Memory
Population
E2022 POST Fail
E2110 MBE Crd #
DIMM ## &
##
E2111 SBE Log
Disable Crd
# DIMM ##
Causes
Dell Remote Assistant
Card (DRAC)
configuration failure.
processor configuration
failure.
Incorrect memory
configuration. Memory
population order incorrect.
General failure after video. Check screen for specific
One of the DIMMs in the
set implicated by "## &
##" has had a memory
multi-bit error (MBE). If
no memory card is present,
the "Crd #" string is left
out of the message.
The system BIOS has
disabled memory single-bit
error (SBE) logging, and
will not resume logging
further SBEs until the
system is rebooted. "##"
represents the DIMM
implicated by the BIOS. If
no memory riser card is
present, the "Crd #" string
is left out of the message.
Corrective Actions
Check screen for specific
error messages.
Ensure that DRAC cables
and connectors are
properly seated. If problem
persists, see your DRAC
documentation.
Check screen for specific
error messages.
Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 139.
error messages.
See "Troubleshooting
System Memory" on
page 139.
See "Troubleshooting
System Memory" on
page 139.