5-14 Compaq ProLiant Clusters for SCO UnixWare 7 U/300 Quick Install Guide for the Compaq ProLiant ML370
Cluster Resource Problems
Problem
Device is not seen on all nodes
in a cluster
Not all processors seem to be
usable
Not all of the memory in a node
is used
This section addresses problems relating to cluster resources.
Solving Cluster Resource Problems
Possible Cause
Mismatched kernels
Not all nodes have been
rebooted after kernel change
Incorrect UnixWare licenses on a
node
Incorrect UnixWare licenses on a
node
Table 5-6
Action
Ensure that all nodes are in the
cluster, and then reboot node 2.
When installing a software
package that includes a
loadable kernel module and
requires a node reboot, ALL
nodes in the cluster must be
rebooted by using the
cluster-wide reboot
(shutdown-i6).
Update the UnixWare licenses
for that node through the
SCOadmin license manager so
that all processors are properly
licensed. Perform a
clusternode_shutdown and
reboot that node.
Update the UnixWare licenses
for that node through the
SCOadmin license manager so
that use of the full memory is
properly licensed. Perform a
clusternode_shutdown and
reboot that node.