  • Page 1 Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs Release: 6.2 Document Revision: 03.01 www.nortel.com NN47200-302...
  • Page 2 While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject to change without notice.
  • Page 3: Table Of Contents

    T1 SFP specifications 31 T1 SFP—default settings 34 1000BASE-T SFP specifications 35 1000BASE-SX (LC) SFP specifications 35 Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 4 10GBASE-LRM XFP specifications 56 10GBASE-LR/LW XFP specifications 58 10GBASE-ER/EW XFP specifications 60 10GBASE-ZR/ZW XFP specifications 61 Index Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 5: New In This Release

    5000 Series Installation — SFPs (NN47200-302) for release 6.2. Features See the following sections for information about feature changes. Support for additional SFPs The 5000 Series switches support eight additional SFPs in Release 6.2. See the following for more information: • “T1 SFP specifications” (page 31) •...
  • Page 6 6 New in this release Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 7: Introduction

    “SFP specifications” (page 29) • “10 Gigabit small form factor pluggable transceivers” (page 47) • “XFP specifications” (page 53) Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 8 8 Introduction Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 9: Safety And Equipment Care Information

    The wrist strap must touch the skin and be grounded through a one megaohm resistor. • Do not touch anyone who is not grounded. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 10: Care Of Fiber Optic Equipment

    Frequent overstressing of fiber optic cable causes progressive degeneration that leads to failure. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 11: Fiber Optic Connector Care

    Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 12: Cleaning Single Connectors

    To avoid eye irritation on contact, wear safety glasses when working with isopropyl alcohol. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 13: Procedure Steps

    • You need a fiber optic microscope to inspect connectors. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 14: Cleaning Receptacles

    Clean connector receptacles or ports so that the optical signal is minimally attenuated by the connection. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 15 If problems persist, ensure that the connector or receptacle is free from damage. --End-- Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 16: Product Safety Warnings And Information

    Para evitar danos com descarga eletrostática, sempre use uma pulseira antiestática que esteja conectada a uma tomada ESD. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 17: Laser Safety Warnings

    Questo prodotto può essere installato solo da personale esperto. Laser safety warnings This section provides laser safety warnings. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 18 Tenha sempre em mente que os cabos de fibra ótica estão ligados a uma fonte de luz. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 19 Tenere sempre presente che i cavi a fibra ottica sono collegati a una sorgente luminosa. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 20 20 Safety and equipment care information Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 21: Small Form Factor Pluggable Transceivers

    Determine the required media and connector type. You need fiber optic cable for a reach over 100 m. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 22: Job Aid

    Up to 120 km reach over a single mode fiber pair. Job aid SFPs are hot-swappable input and output enhancement components designed for use with Nortel products to allow gigabit Ethernet ports to link with other gigabit Ethernet ports over various media types. Nortel Ethernet Routing Switch 5000 Series Installation —...
  • Page 23: Job Aid

    SFP. A future release will provide access to the DDI information. The SFPs described in this section are all RoHS -E6 compliant. The following table lists and describes the Nortel SFP models with DDI capability. All these SFPs use LC connectors. Nortel Ethernet Routing Switch 5000 Series Installation —...
  • Page 24: Installing An Sfp

    Install an SFP to provide an interface between the switch and the network cable. Installing an SFP takes about three minutes. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 25 Apply a light pressure to the device until it clicks and locks into position. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 26: Job Aid

    The following figure shows the wrap-around latch-type extraction mechanism. To remove the device, push the collar towards the module. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 27: Removing An Sfp

    Depending on your SFP model, to release the SFP, press the locking and extractor mechanism. Slide the SFP out of the module SFP slot. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 28 If you discard the SFP, be sure to dispose of it according to all national laws and regulations. --End-- Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 29: Sfp Specifications

    “1000BASE-XD DDI 1550 nm SFP specifications” (page 40) • “1000BASE-ZX DDI SFP specifications” (page 41) • “1000BASE-XD DDI CWDM SFP specifications” (page 42) Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 30: Sfp Labels

    “1000BASE-BX40 DDI SFP specifications” (page 44) • “1000BASE-EX DDI SFP specifications” (page 45) SFP labels The Nortel label on a typical SFP contains a Nortel serial number, a bar code, a manufacturer code, an interface type, and a part number. Figure 1 SFP label General SFP specifications...
  • Page 31: 100Base-Fx Sfp Specifications

    WAN speed. The system uses this value for STP path cost and MLT utilization. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 32 32 SFP specifications ATTENTION Nortel recommends that you enable egress traffic shaping on the port to 1.544 Mbps when using the T1 SFP to guarantee appropriate Quality of Service and traffic prioritization. The following table describes the T1 SFP specifications.
  • Page 33 Receive shield Transmit shield Transmit ring Receive ring Transmit tip Receive tip Transmit shield Receive shield Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 34: T1 Sfp-Default Settings

    Line code: Binary 8 Zero Substitution (B8ZS) or Alternate Mark Inversion (AMI). • Clock: Use Rx clock or internal clock for Tx clock (Nortel recommends internal clock for Tx clock). • Framing: D4 or Extended Super Frame (ESF), depends on the framing word required by the T1 equipment at the far end.
  • Page 35: 1000Base-T Sfp Specifications

    1000BASE-SX (LC) SFP specifications 35 ATTENTION You must configure the T1 SFP module to match the parameters of the T1 equipment at the far end. If you must change the parameters, contact Nortel Technical Support. 1000BASE-T SFP specifications The 1000BASE-T SFP provides gigabit Ethernet connectivity using a single eight-pin RJ-45 connector.
  • Page 36: 1000Base-Sx (Mt-Rj) Sfp Specifications

    – 10 to – 4.0 dBm Receiver characteristics Receiver sensitivity – 17 dBm Maximum input power 0 dBm Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 37: 1000Base-Lx Sfp Specifications

    4 dB when you test the CWDM SFP in loopback mode, or use short runs of fiber with no intermediate CWDM OADM or CWDM OMUX. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 38: 1000Base-Zx Cwdm Sfp Specifications

    – 3.0 to 2.0 dBm Receiver characteristics Receiver sensitivity – 23 dBm Maximum input power – 3.0 dBm Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 39: 1000Base-Sx Ddi Sfp Specifications

    Link optical power budget 9.5 dB Transmitter characteristics Launch power – 9.5 to -3.0 dBm Receiver characteristics Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 40: 1000Base-Xd Ddi 1310 Nm Sfp Specifications

    1000BASE-XD DDI 1550 nm SFP specifications Parameter Specification Maximum electrical power consumption 1.0 W Connectors Duplex LC Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 41: 1000Base-Zx Ddi Sfp Specifications

    0 to 5 dBm Receiver characteristics Receiver sensitivity – 24 dBm Maximum receiver power – 0 dBm Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 42: 1000Base-Xd Ddi Cwdm Sfp Specifications

    1000BASE-ZX CWDM SFP DDI (70 km) specifications Parameter Specifications Maximum electrical power consumption 1.0 W Connectors Duplex LC Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 43: 1000Base-Bx10 Ddi Sfp Specifications

    For example, if you install 20 fiber pairs with 20 conventional ports connected, you can use 1000BASE-BX SFPs to expand to 40 ports, using the same fiber. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 44: 1000Base-Bx40 Ddi Sfp Specifications

    The long wavelength optical transceivers used in these models provide variable distance ranges using single mode fiber optic cabling. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 45: 1000Base-Ex Ddi Sfp Specifications

    1550 nm and has a reach of up to 120 km. The part number of this SFP is AA1419071-E6. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 46 0 to 5.0 dBm Receiver characteristics Receiver sensitivity – 30 dBm Maximum receiver power – 9.0 dBm Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 47: Gigabit Small Form Factor Pluggable Transceivers

    (XFP) transceivers, and lists some technical specifications for the supported XFP models. ATTENTION Nortel recommends that you only use Nortel-qualified XFPs. If you do choose to use other vendor XFPs, be aware that Nortel does not support the use of other XFPs. Navigation •...
  • Page 48: Job Aid

    Job aid XFPs are hot-swappable input and output enhancement components designed for use with Nortel products to allow 10 gigabit Ethernet ports to link with other 10 gigabit Ethernet ports. All Nortel XFPs use Lucent connectors (LC) to provide precision keying and low interface losses.
  • Page 49: Installing An Xfp

    ESD jack. CAUTION Risk of equipment damage Only trained personnel can install this product. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 50: Procedure Steps

    The following figure shows a typical bail-type mechanism used on XFP transceivers. Pull the bail down to release the device. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 51: Removing An Xfp

    If you discard the XFP, be sure to dispose of it according to all national laws and regulations. --End-- Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 52 52 10 Gigabit small form factor pluggable transceivers Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 53: Xfp Specifications

    All Nortel XFPs meet or exceed these standards. ATTENTION Nortel recommends that you only use Nortel-qualified XFPs. If you do choose to use other vendor XFPs, be aware that Nortel does not support the use of other XFPs. Navigation •...
  • Page 54: General Xfp Specifications

    The 10GBASE-SR XFP is supported by the Ethernet Routing Switch 5530 (not by the 5510 or 5520), and by the Ethernet Routing Switch 5600 Series. Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 55 Maximum average receive power for 0 dBm damage Maximum receiver sensitivity in OMA – 11.1 dBm Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 56: 10Gbase-Lrm Xfp Specifications

    The stressed sensitivity values are for system level BER measurements, which include the effects of clock and data recovery (CDR) circuits. Nortel recommends that you allocate at least 0.4 dB additional margin if you make component level measurements without the effect of CDR circuits.
  • Page 57 Up to 220 m 1.9 dB • 500 MHz-km at 850 nm • 500 MHz-km at 1300 nm Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 58: 10Gbase-Lr/Lw Xfp Specifications

    IEEE 802.3ae standard. Table 29 IEEE 802.3ae 10GBASE-LR/LW XFP specifications Parameter Specifications MTBF 675 000 hours Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 59 PDM, laser shutdown for safety conditions, activation of a PMD_global_transmit_disable or other optional transmitter shut down condition Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 60: 10Gbase-Er/Ew Xfp Specifications

    Stressed receiver sensitivity in OMA – 11.3 dBm Receive electrical 3 dB upper cutoff frequency 12.3 GHz (maximum) Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 61: 10Gbase-Zr/Zw Xfp Specifications

    – 128 dB/Hz Maximum optical return loss tolerance – 26 dB Maximum transmitter reflectance – 12 dB Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 62 5.0 dBm Receiver reflectance (maximum) – 27 dB Receive electrical 3 dB upper cutoff frequency 9.3 GHz Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 63: Index

    100BASE-FX AA1419070-E6 24, 43 SFP 23, 31 AA1419071-E6 24, 45 10GBASE-ER/EW AA1419074-E6 23, 31 XFP 60 Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 64 24 label 30 lock and extraction mechanisms 26 physical specifications 30 removal 27 selection 21 Nortel Ethernet Routing Switch 5000 Series Installation — SFPs and XFPs NN47200-302 03.01 28 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 66 While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject to change without notice.