  • Page 1 M AG US META L D 6 3 0 LC D M E TA LLU RG ICA L D IG ITA L M I C RO S C OP E U S E R M A N U A L...
  • Page 2 928 E 124th Ave. Ste D, Tampa, FL 33612, USA +1 813 468-3001 contact_us@levenhuk.com Levenhuk Optics s.r.o. (Europe) V Chotejně 700/7, 102 00 Prague 102, Czech Republic +420 737 004-919 sales-info@levenhuk.cz Magus® is a registered trademark of Levenhuk, Inc. © 2006–2024 Levenhuk, Inc. All rights reserved. www.levenhuk.com 20241122...
  • Page 3: Safety Precautions

    Before using the microscope, please read this user manual carefully to study the instrument design, operation modes and procedures, operational limitations, and safety precautions. Due to the continuous improvements in the microscope design, this manual may not reflect minor design changes that do not affect the microscope performance and operation procedures.
  • Page 4 11. Bulb installation: – Do not touch the glass surface of the bulb with your bare hands. When installing the bulb, wear gloves or wrap the bulb with a cotton cloth. – Use a clean cotton cloth moistened with alcohol-based disinfectant to wipe dirt off the surface of the bulb.
  • Page 5: Table Of Contents

    CONTENTS 1 DESCRIPTION Purpose Specifications Microscope kit 2 COMPONENTS Microscope body Focusing mechanism Microscope head Eyepieces Revolving nosepiece Objectives Reflected light illuminator Stage Lamphouse Polarizer/analyzer set Color filters Camera Monitor 3 UNPACKING AND ASSEMBLING 4 BRIGHTFIELD OBSERVATION PROCEDURE Switching on the illumination Using the beam splitter lever Placing the specimen Focusing on the specimen...
  • Page 6: Description

    MAGUS Metal D630 LCD Metallurgical Digital Microscope has been designed and tested in accordance with the international safety standards. If properly used, the microscope is safe for the customer’s health, life, property, and the environment. Proper maintenance of the microscope is a prerequisite for its reliable and safe operation.
  • Page 7 Camera Number of megapixels Sensor SONY Starvis Exmor CMOS Color/monochrome Color Maximum resolution, pix 1920х1080 Sensor size 1/2" (7.2х4.05mm) Pixel size, µm 3.75x3.75 Signal/noise ratio 0.15mV with 1/30s Light sensitivity 425mV with 1/30s Exposure 0.04ms–1000ms Video recording Frame rate, fps at resolution, pix 60@1920х1080 (HDMI), 50@1920х1080 (USB) Image format *.jpg,*.tif...
  • Page 8: Microscope Kit

    M ICROS COPE K IT The microscope kit includes the following main components: – stand with base and stage – microscope body with focusing mechanism and revolving nosepiece – reflected light illuminator – trinocular head – lamphouse – set of objectives and eyepieces –...
  • Page 9 21. Lamphouse 14. Stage 22. Lamp adjustment knobs 15. Microscope base 23. ON/OFF switch 16. X/Y stage control knob 24. Brightness adjustment knob 17. Objectives 25. Digital camera 18. Revolving nosepiece 26. Monitor Fig. 1. MAGUS Metal D630 LCD Microscope...
  • Page 10: Components

    COMPONENTS MI CRO SCOPE B ODY The microscope body 9 (Fig. 1) is mounted on the stand 6 (Fig. 1) that is secured on the base 15 (Fig. 1). There is a focusing mechanism inside the microscope body. There is a mount on the front of the microscope body to install the revolving nosepiece 17 (Fig. 1) and the reflected light illuminator 3 (Fig.
  • Page 11: Objectives

    The revolving nosepiece rotates clockwise and counter-clockwise. The revolving nosepiece is mounted on the front panel of the microscope body. The objectives are screwed clockwise into the revolving nosepiece in order of increasing magnification. For convenience, the objectives are turned "away from the observer".
  • Page 12: Camera

    CAM E RA The digital camera equipped with the SONY CMOS Exmor sensor delivers high light sensitivity and low noise performance. The camera is powered via a 12V/1A AC power adapter. MONITO R The monitor is designed to use a visualization system of the MAGUS microscope. It connects to a microscope-mounted camera to display a real-time image.
  • Page 13: Brightfield Observation Procedure

    3. Take out the reflected light illuminator 2 and lamphouse 5. Install the illuminator using the mount on the microscope body and secure it with the Allen wrench. Mount the lamphouse on the side of the illuminator, connect the power cord to the microscope.
  • Page 14: Focusing On The Specimen

    FOC U S I N G ON T H E S PEC I MEN Focusing on the specimen is achieved by coarse and fine focusing knobs. Perform the focusing using the 10x objective. Rotate the coarse focusing knob 2 to raise the objective as far as it will go.
  • Page 15: Setting Up Köhler Illumination

    4. If the filament image is blurry, adjust the position of the collector using the knob 7. 5. If the filament image is offset from the center of the light spot, manipulate the lateral alignment knob 5 and the vertical alignment knob 6 to center the light source. Fig.
  • Page 16: Using The Color Filters

    The aperture diaphragm 3 is pre-centered at the factory and requires no additional centering. When using low- magnification objectives, increase the aperture diaphragm opening; when using high-magnification objectives, reduce the aperture diaphragm opening. US IN G T H E C OLOR F I LT E R S A round slider with color filters is installed on the top of the reflected light illuminator.
  • Page 17: Using The Camera

    USI N G THE CA ME RA The digital camera is equipped with a 2MP sensor producing a realistic image in Full HD resolution (1920x1080 pixels). The microscope is designed to observe a specimen through the eyepieces and to photograph the specimen. The microscope has a trinocular tube.
  • Page 18: Using The Monitor

    U SING THE M O N I TO R The IPS matrix delivers a bright image with large viewing angles, which allows you to look at the display even at an angle with no color distortion. To display the image on the screen: –...
  • Page 19: Calibration Slide With A Camera

    Work out the value for one eyepiece division using each objective by formula Е = ТL/A, where: E – eyepiece division value Т – stage division value specified on the stage micrometer (0.01mm) L – number of stage micrometer divisions A –...
  • Page 20: Troubleshooting

    6 TROUBLESHOOTING Potential problems and remedies (Table 4): Problem Cause Remedy ELECTRI CAL C OMPONENTS The ON/OFF switch is off Switch on the ON/OFF switch The halogen bulb is damaged Replace the halogen bulb The fuse has blown Replace the fuse No illumination in the field Poor electrical contact Check all the connectors.
  • Page 21: Scope Of Delivery

    7 SCOPE OF DELIVERY The scope of delivery (Table 5). Component Note MI CRO SCOPE MAIN COMPONENTS Stand with base and stage Microscope body Reflected light illuminator Lamphouse Trinocular microscope head Revolving nosepiece Power supply unit Polarizer/analyzer set Color filter slider REPLACEABLE PARTS Infinity plan achromatic objective: PL L 5х/0.12 WD 26.1mm Infinity plan achromatic objective: PL L 10х/0.25 WD 20.2mm...
  • Page 22: Care And Maintenance

    USB 2.0 cable (2 m) USB mouse 32GB SD memory card EU-plug 12V/1A AC power adapter Flash drive with drivers and software Fasteners (mounting plate and screws) User manual M ONITO R Monitor HDMI cable AC power adapter DC/DC Type-C adapter Fasteners (Allen wrench and screws) CARE AND MAINTENANCE RE PLACING T HE B ULB A N D TH E FU SE...
  • Page 23: Maintenance

    MAGUS provides a 5-year international warranty from date of purchase (valid for the entire life of the instrument). The Levenhuk company warrants the product to be free from defects in materials and workmanship. The Seller warrants that the MAGUS product you have purchased meets specification requirements, provided that the Buyer complies with terms and conditions of transport, storage, and operation of the product.
  • Page 24 www.magusmicro.com...