Page 1
A H- X P 1 3 C P B A U - X 1 3 C P B "Plasmacluster" and "Device of a cluster of grapes" are registered trademarks or trademarks of Sharp Corporation. 01_TINSEB172JBRZ 25A-TH1_EN.indd 1 28/11/2567 BE 09:52...
Please read this manual carefully before using the product. This manual should be kept in a safe place for handy reference. Read the SAFETY PRECAUTIONS in this manual carefully before operating the unit. This appliance is filled with refrigerant R32. C O N T EN T S •...
I n t r o d u c i n g A i r e s t Airest is a mini-split equipped with built-in air purifier. Air Pollutant The air purifier functions in all modes of Main Filters operation: AUTO, COOL, DRY, and AIR PURIFIER (Fan only) modes. Filtered Air Airest can work for you 365 days a year. Im p o r t a n t : B e f o r e u s e Prefilter Filter Brackets 1.
Safety Precautions W A R NING • Do not pull or deform the power supply cord. Pulling and misuse of the power supply cord can result in damage to the unit and cause electrical shock. • Be careful not to expose your body directly to the outlet air for a long time. It may affect your physical conditions.
Page 5
• Do not block the air inlets nor outlets of the unit. It may cause insufficient performance or troubles. • Be sure to stop the operation and turn the circuit breaker off before performing any maintenance or cleaning. A fan is rotating inside the unit and you may get injured. • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
P a r t N a m e s IND O O R U NIT Sensing Area Dust Sensor and Odor Sensor are installed inside. Pull out Sensor Filter • Pull out for maintenance only. Sensor Box ※ Indoor unit design may differ from the image. Air Inlet Filter Bracket (Prefilter & Main Filter) Airflow Panel...
Page 7
I n d i c a t o r s Operation Indicator Timer Indicator Clean Indicator ( In spectrum ) Ion Indicator WLAN Indicator Indicators Color Indication White AIR PURIFIER operation Operation Green AUTO,COOL,DRY operation Timer Orange Timer is set AFTER CARE in operation •...
R e m o t e C o n t r o l B U T T O NS 1 TRANSMITTER BUTTONS 2 AIR PURIFIER 3 COOL 4 TEMPERATURE 5 SUPER JET 6 ECO 7 AUTO 8 SLEEP 9 DRY 10 STOP 11 LOUVER (vertical direction) 12 LOUVER (horizontal direction)
Page 9
LO A D ING B A T T ER IES Use two AAA (R03) batteries. Slide down the battery cover. Load batteries. Make sure the (+) and (-) polarities are correctly aligned. • The display shows “6:00 AM” when batteries are properly loaded. Battery Cover Put back the cover. NO T E: • The battery life is approximately 1 year. When you see on the display, replace them.
O N/ O F F B u t t o n o n t h e U n i t This button allows you to operate the unit without the remote control. T U R N O N P r e s s t h e O N/ O F F b u t t o n . •...
LAN network. F U NC T IO NS O NLY O N T HE A P P . SHARP AIR APP offers enhanced convenience and additional features to optimize your air conditioning experience. A I Sl e e p AI Sleep optimizes temperature setback R o o m t e m p .
B a s i c O p e r a t i o n T U R N O N A U T O m o d e The temperature setting and mode are automatically selected according to the room temperature when the unit is turned on. P r e s s •...
Page 13
C HA NGE T EM P ER A T U R E SET T INGS P r e s s • You can set temperature in increments of 0.5°C. A U T O / D R Y m o d e You can change the temperature up to ±2.0°C from the automatic setting.
Fan Speed and Airflow Direction F A N SP EED P r e s s (AUTO) (QUIET) (SOFT) (LOW) (HIGH) A b o u t A U T O f a n s p e e d With AUTO fan speed, the unit regulates the fan speed for best performance.
S u p e r J e t In Super Jet, the unit works at the maximum power and optimum louver direction to cool the room. P r e s s d u r i n g C O O L. “. • The remote control displays “ • The temperature display goes off and sets automatically. • The vertical airflow louver will be set obliquely downward.
E C O M o d e The unit saves power consumption in ECO mode. P r e s s d u r i n g A U T O , C O O L o r D R Y . • The remote control displays “ “ or “...
Baby Mode Soft , quiet and clean operation provides optimized cooling for infants. P r e s s d u r i n g o p e r a t i o n . • The remote control will display “ “. • Fan speed will be automatically set to LOW, SOFT or QUIET. • Louver will be set to top position (Coanda position). • Even if PLASMACLUSTER setting is turned off, it will automatically be turned on during Baby Mode operation.
Page 18
T i m e r Before setting the timer, make sure the clock shows the accurate time. O f f - T i m e r P r e s s “ ” o n t h e r e m o t e c o n t r o l b l i n k s ; p r e s s t o s e t t i m e i n i n c r e m e n t s o f 1 0 m i n u t e s .
C A NC EL T IM ER S ( O f f - T i m e r a n d O n - T i m e r ) P r e s s • on the unit goes off. •...
Page 20
C h a n g e D e f a u l t S e t t i n g s You can change certain settings according to your preferences. , until your desired menu shows up. P r e s s Automated AFTER CARE Plasmacluster Ions OD Silent...
Page 21
M ENU SET T INGS ( Default settings) When you turn off “ O n ” “ O f f ” AUTO, COOL or DRY modes, the unit A u t o m a t e d runs AFTER CARE automatically.
A F T E R C A R E AFTER CARE runs FAN mode to dry out the inside of the unit and reduce mold growth and odor. A u t o m a t e d A F T ER C A R E After running AUTO, COOL and DRY modes, AFTER CARE runs automatically f o r 9 0 m i n u t e s .
M a i n t e n a n c e Be sure to disconnect the power cord from the wall outlet or turn off the circuit breaker before performing any maintenance. In d o o r U n i t e x t e r i o r & R e m o t e C o n t r o l - only when dirty - Wipe gently with a soft cloth.
Page 25
- Only when dirty - Se n s i n g A r e a Vacuum dust with a handy vacuum cleaner. Sensing Area If the dust is persistant, take out the Sensor Box and wash the Sensor Filter and dry completely. Sensor Box Sensor Filter (reversible) T a k i n g o u t Se n s o r B o x STOP any mode of operation and Airflow Panel p r e s s...
Page 26
M a i n t e n a n c e Airest has two types of filters: Prefilter • Prefilter • Main Filter Each type has different maintenance procedures as below: Main Filter Filter Bracket P refilter - every 6 months - Vacuum the dust with a handy vacuum cleaner. Place a sheet of paper to protect the floor.
Page 27
T u r n i n g t h e u n i t b a c k o n Reassemble the Prefilter. Prefilter 3 tabs • Insert tabs on the Filter Bracket into Prefilter’s slots. • Lock left and right sides near in the middle.
Page 28
M a i n t e n a n c e M a i n F i l t e r - When dust accumulates or unpleasant smell is coming out from the air outlet - Vacuum the dust with a handy vacuum cleaner. NO T W A SH O R D R Y IN T HE SU N.
Page 29
T u r n i n g t h e u n i t b a c k o n P l a c e t h e M a i n F i l t e r i n t o t h e F i l t e r B r a c k e t w i t h t h e t a g f a c i n g u p .
Page 30
M a i n t e n a n c e REPLACING MAIN FILTER When Main Filter reaches the end of its life, Clean Indicator Clean Indicator will blink yellow 10 times at the start of any operation mode. • Filter life is approximately 1.5 to 2 years but the end of life may come earlier depending on the total operating time and environment. Airest determines the filter life when its (yellow)
T r o u b l e S h o o t i n g A l e r t i n g i n d i c a t i o n s f r o m i n d o o r u n i t Notifications In d i c a t o r s An error has occurred.
Page 32
T r o u b l e S h o o t i n g C h e c k t h e f o l l o w i n g p o i n t s b e f o r e c a l l i n g f o r s e r v i c e . T h e u n i t d o e s n o t r e s p o n d • The unit will be in a pending state for some time after it is turned off or the operating mode is changed.
Page 33
No o r w e a k w i n d • Did you take out the Main Filter from the plastic bag? • Clean Prefilter if dusted. It t a k e s l o n g t o r e a c h t o t h e d e s i r e d t e m p e r a t u r e •...
C h e c k i n g t h e E r r o r C o d e You can check the error code using remote control. The error code contains Main Code and Sub Code. Ex a m p l e : error 23-4. P r e s s "...
Page 68
Testé par des tiers indépendants. Validé par les consommateurs. SUPERFICIE SUGGÉRÉE DE LA PIÈCE FERMÉE SQUARE FEET 44 m D É B I T D ’ A I R P R O P R E S O U F F L É Plus les valeurs CADR sont élevées, plus les appareils nettoient rapidement l’air FUMÉE DE TABAC POUSSIÈRE...
Need help?
Do you have a question about the AH-XP13CPB and is the answer not in the manual?
Questions and answers