MONITOR REPLACEMENT KIT OP26-49
REPLACEMENT INSTRUCTIONS
MONITOR UNIT
These instructions describe how to replace the MU-201C with the MU-192, using the monitor re-
placement kit (OP26-49). The OP26-49 allows you to install the MU-192 to the existing mounting
hole for the MU-201C.
Monitor Replacement Kit OP26-49 (Code No.: 001-661-300)
Name
Type
Conversion Attachment
OP26-49-1
Flush Mounting Sponge H19
26-005-3123-1
26-005-3123-0
Rosette Washer
M6 C2700W
Binding Head Screw
M4X10 SUS304
Oval Head Tapping Screw
6X30 SUS304
1.
Attach the flush mounting sponges H19 (sup-
plied with this kit, thickness: 2 mm) and V19
(supplied with the MU-192, thickness: 2 mm) to
the back of the MU-192 in the order shown in the
right-hand figure.
Note: Place the unit facedown on a soft, clean
surface to prevent damage to the LCD.
2.
Attach the conversion attachment to the MU-192, using the eight binding screws (M4×10).
The cutout on the conversion attachment must face to the bottom of the unit.
Conversion attachment
All brand and product names are trademarks, registered
trademarks or service marks of their respective holders.
www.furuno.com
MU-192
Model
Code No.
Qty
001-661-310
1
100-351-551-10
2
100-351-550-10
000-165-694-10
4
000-172-165-10
8
000-175-381-10
4
Flush mounting
Flush mounting
sponge H19
sponge V19
2 2
1 1
3 3
4 4
Binding screw
(M4×10, 8 pcs)
The cutout must face to
the bottom of the unit.
3.
Remove four panel caps and self-tapping screws (φ6×30)
from the MU-201C to remove the unit from the mounting
hole, then disconnect all cables.
The panel caps and self-tapping screws can be discarded.
4.
Connect all cables to the MU-192, referring to section "1.8 Wiring" in the Operator's Manual
of the MU-192.
Remove the terminal board cover at the bottom of the MU-192 to connect the power cable to
the terminal board with crimp-on lugs. Make sure to reattach the cover after connecting the
cable.
5.
Set the MU-192 to the mounting hole, then secure the unit using the four oval head tapping
screws (φ6×30) and rosette washers (M6).
Rosette washer
Oval head tapping screw
(ø6×30, 4 pcs)
Panel cap
Self-tapping screw
MU-201C
2

Advertisement

loading
Need help?

Need help?

Do you have a question about the OP26-49 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Furuno OP26-49

  • Page 1 The panel caps and self-tapping screws can be discarded. Model These instructions describe how to replace the MU-201C with the MU-192, using the monitor re- placement kit (OP26-49). The OP26-49 allows you to install the MU-192 to the existing mounting hole for the MU-201C. MU-201C Monitor Replacement Kit OP26-49 (Code No.: 001-661-300)
  • Page 2 Pub. No. C42-02405-A (2410, REFU) MU-192 www.furuno.com Printed in Japan...

This manual is also suitable for:

01-661-300