Installation & Control Guide for Heatstore Panel Heater Models HSP500T HSP750T HSP1000T HSP1250T HSP1500T HSP2000T All electrical appliances produced by the company are guaranteed for two years against faulty materials or workmanship. This applies only if the appliance has been used for...
Overview switches the heater off if, for any reason, the appliance overheats. The TOC can only be re-set Please read this guide carefully and retain after the appliance has cooled down. In order to for future use and maintenance. re-set the TOC, proceed as follows: This appliance has been designed and •...
Installation Fig. 1 195mm ILLIMETRES ATTS HSP500T HSP750T HSP1000T 1000 HSP1250T 1250 HSP1500T 1500 HSP2000T 2000 Note: The heater MUST be fully secured in the vertical position before being switched on. It must be ‘clicked’ into the locking tabs. See section 11 for more mounting information.
Page 4
MODE/MENU INCREASE VALUE STANDBY DECREASE VALUE 1.Basic Operations When the room temperature reaches the set temperature, the heating is disabled. The HSP-T has 4 standard operating modes: BOOST, MANUAL, SETB and PROG. Each mode can be selected by pressing the MENU button to cycle through the options.
Page 5
6. Heat symbol 6. Heat Symbol The system has been factory set to default time and temperature values. If necessary, all Every time there is a demand for heat, the values can be adjusted. When the heating is display will show the heat icon. on, open window detection sensor will automatically switch the heater off when it detects a fall in temperature of 2°C in less than...
Page 6
12. Setting the automatic program schedule An example of one day program on HSP-T PROGRAM 1 PROGRAM 2 PROGRAM 5 PROGRAM 6 ºC PROGRAM PROGRAM 19ºC 22ºC 22ºC 16ºC 10ºC 4ºC 06:00 08:00 12:00 14:00 16:00 22:00 Step 4: Press the MENU button. The temperature should flash.
Page 7
13. Overview of program mode Alternatively, it is possible to copy a program from one day to another. The HSP-T has a 7-day, 5-day + 2-day and a 24 To do this, follow the steps below; hour timer available. This can be chosen in the setup menu.
Page 8
1 - Temperature calibration 7 - Temperature drop in open window detection time The temperature reading is factory calibrated but if for any reason it needs adjusting (better accuracy required, to suit different position in the room etc.), the reading can be recalibrated in 0.5 degree steps.