Direct vent gas fireplace heater
Table of Contents

Advertisement

Quick Links

INSTALLER: Leave this manual with the appliance
CONSUMER: Retain this manual for future reference
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gasses, unless a
certified kit is used.
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and must be installed.
85-03-01307
Installation and Operating Instruction
AA-11-05433 FV46 FireIn DIRECT VENT GAS FIREPLACE HEATER
FV46 FireIn
INSTALLATEUR : Laissez ce manuel avec l'appareil
CONSOMMATEUR : Conservez ce manuel pour référence future
AVERTISSEMENT:
RISQUE D'INCENDIE OU D'EXPLOSION
Le non-respect des avertissements de sécurité à la lettre
peut entraîner des blessures graves, la mort ou des
dommages matériels.
Ne pas entreposer ni utiliser d'essence ni d'autres vapeurs
ou liquids inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incendies.
- L'installation et l'entretien doivent être assurés par un
Cet appareil peut être installé dans une maison
préfabriquée (É.-U. seulement) ou mobile déjà installée à
demeure si les règlements locaux le permettent.
Cet appareil doit être utilisé uniquement avec les types de
gaz indiqués sur la plaque signalétique. Une trousse de
conversion est fournie avec cet appareil.
Une barrière conçue pour réduire le risque de brûlures
du verre chaud est fournie avec cet appareil et doit être
installée.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AA-11-05433 and is the answer not in the manual?

Questions and answers

Summary of Contents for Mendota AA-11-05433

  • Page 1 Installation and Operating Instruction AA-11-05433 FV46 FireIn DIRECT VENT GAS FIREPLACE HEATER INSTALLATEUR : Laissez ce manuel avec l’appareil INSTALLER: Leave this manual with the appliance CONSOMMATEUR : Conservez ce manuel pour référence future CONSUMER: Retain this manual for future reference...
  • Page 2: Read Me First

    The installer should perform these initial curing cycle procedures as the final step in the installation process before finishing materials are installed around this fireplace. See chapter 3.1.1 Mendota Fireplace Curing Instructions. Read and follow all instructions given in this Chapter and perform the 3-step curing cycle.
  • Page 3: Table Of Contents

    1.3 H ........2 URFACES ARE ORMAL 1.4 P ....2 ERIODIC AND ANNUAL CLEANING ARE REQUIRED 2.1 SAFETY AND WARNING INFORMATION ....5 3.2.17.3.1 Mendota Cool Wall ..........33 3.2.17.3.2 Versiheat 2.2 S ............6 AFETY ARNINGS 3.2.17.3.3 FlexHeat 2.3 R ..9...
  • Page 4 5.8 F ......79 IRST IGHTING NSTRUCTIONS 4.11 V ............... 59 ENTING 5.9 O ........79 PERATING NSTRUCTIONS 5.10 T ........ 79 AS TO IREPLACE 5.11 FREQUENTLY ASKED QUESTIONS ......80 4.12 POWER VENTING ..........68 6.1 R ....... 84 EQUIRED ERIODIC NSPECTIONS...
  • Page 5: Safety And Warning Information

    Building Permit & Inspection Requirements All installations of Mendota Fireplaces must comply with all the requirements stated in this Installation and Operating Manual. The dealer and/or installer must obtain all required building permits and inspection approvals from the local building inspection department or the local jurisdiction.
  • Page 6: Safety Warnings

    HIGH-ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7,500 ft., understand the need for gas input derating. Contact your local gas company to see if your gas type is already derated for your altitude or contact Mendota Technical Service for support.
  • Page 7 Never obstruct the flow of combustion and ventilation air. Keep the front of the fireplace clear of all obstacles and materials for servicing and proper operation. Use only Mendota approved Screens, Fronts and Trim Kits. Due to high temperature, the fireplace should be located out of traffic areas and away from furniture and draperies.
  • Page 8 été plongée dans l’eau. Do not use any fronts or doors with this fireplace unless they are certified by Mendota and installed by a certified installer.
  • Page 9: Requirements For The Commonwealth Of Mass

    2.3 REQUIREMENTS FOR THE COMMONWEALTH OF MASS. The information in this section applies to all installations performed in the Common Wealth of Massachusetts only. For all side wall, horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes and where the side wall exhaust vent termination is less than seven (7) feet above grade, the following requirements shall be satisfied: 1.
  • Page 10: General Technical References

    If the ignition system goes into lockout mode, always wait 5 minutes before attempting to re-light. Never block off convection air openings or paths. Trim panels or surrounds shall not seal ventilation openings in the fireplace. Always use Mendota decorative fronts and Mendota approved vent systems and vent caps only. Keep the flue warm...
  • Page 11 ATTENTION It is important that the blowers are turned on during this step to prevent the curing smoke from staining the wall finish above the fireplace. Mendota recommends completing Step 1 prior to installation of wall finish materials. Visible smoke and strong odor are to be expected during this step. If desired, disable smoke alarms before this step, smoke from the initial curing cycle will set off smoke alarms.
  • Page 12: Mechanical Technical References

    3.2 MECHANICAL TECHNICAL REFERENCES Planning the installation This Mendota Fireplace must be installed and serviced by a qualified installer, service agency, or the gas supplier. When planning on appliance installation, it is necessary to determine the following information before installing: •...
  • Page 13: Listing Label

    Listing Label The listing label is in the air gap below the firebox. It is secured to a chain and loosely inserted in the air gap and can be pulled out to be viewed. Figure 3-2 Listing Label Page 13 85-03-01307 FV46 FireIn...
  • Page 14 Other Warning and Caution Labels The listing label is in the air gap below the Fireplace. It is secured to a chain and left loosely in the air gap and can be pulled out to be viewed. Page 14 85-03-01307 FV46 FireIn...
  • Page 15: Minimum Clearances To Combustible Construction

    FV46 Fireplace Ratings Information This Mendota Fireplace can be installed directly on top of a metal, masonry or wood structural surface. ELECTRICAL REQUIREMENTS: 120 Volts AC, 1.5 Amps (minimum line voltage allowed 110 Volts AC) REQUIRED GAS SUPPLY PRESSURE: NAT. GAS: 7" W.C. [5.0" W.C. MIN., 11" W.C. MAX.] L.P.
  • Page 16 HINT: To greatly reduce surface temperatures surrounding this Fireplace during operation, Mendota recommends operating the integrated convection air blowers which aid in cooling all surrounding surfaces. Mendota Fireplaces comply with ANSI Z21.88-2019 Standards for maximum surface temperatures (ambient plus 117 F) on exposed “combustible”...
  • Page 17: Fireplace Dimensions And Clearances

    Fireplace Dimensions and Clearances 51" MIN. 40-3/4" ENCLOSURE WIDTH 57-1/2" 9-3/8" TO VENT 36-5/8" 19-5/8" PIPE CENTER 22-1/2" MIN. 19-5/8" ENCLOSURE DEPTH ADJACENT WALLS: 57-1/2" 81-1/2" A wall perpendicular to and in front of this fireplace's glass door surface must be at least 16 inches from the side edges of the facing guide.
  • Page 18 Fireplace Features Identification Page 18 85-03-01307 FV46 FireIn...
  • Page 19 Convection Blower System Dual blowers are provided as standard equipment with this FV46 Fireplace. The dual blowers have an air output rating of 190 CFM (in free air). This Fireplace is designed to operate with the blowers turned off or on. Turning the blower on aids in distributing and circulating heat to the room this Fireplace is installed in.
  • Page 20: Rough Framing Dimensions

    Rough Framing Dimensions The enclosure width dimensions must be maintained to Minimum Rough Framing Dimensions allow this fireplace to be centered in the enclosure. After the FV46 Fireplace is inserted into the enclosure, DESCRIPTION DIMENSION (INCHES) the front of the enclosure can be framed to 45” wide. Enclosure Width 51”...
  • Page 21 Clearance from Appliance Side Walls 0" CLEARANCE FROM TOP STANDOFFS 1/2" CLEARANCE FROM BACK 1/2" CLEARANCE FROM SIDES Page 21 85-03-01307 FV46 FireIn...
  • Page 22 Clearances to Combustible Side Walls The minimum distance required from the side edge of the visible glass to a combustible side wall is 16”. Combustible side walls, mantel corbels, mantel legs and other combustible walls and decorative objects must fall behind a 45-degree line extending outward from the side edges of the visible glass unless such objects are more than 16”...
  • Page 23: Clearances To Combustible Mantels

    Clearances to Combustible Mantels Mantel Clearances for this fireplace may be measured from the top of the convection air opening or the floor level of this fireplace. The location that is referenced normally to measure mantel clearances is the Top of the Convection Air Opening. For ease, however, measure up from the floor level of this fireplace.
  • Page 24 If these materials are used it is recommended that the fireplace is raised at least 12” above the floor. Mendota does not guarantee any materials used around the fireplace. Mendota disclaims any and all liability for any damage to finishing materials including warping, discoloring, cracking, peeling or flaking. This also includes any off-gassing or unpleasant smells from materials when they are heated.
  • Page 25 Finishing to the Bottom Guide WARNING: Careful planning is required to insure a proper finish. Many fronts for the fireplace require different finishing guides than what come on the fireplace. Before installing the hearth pad or wall finishing material on the fireplace insure the correct finishing guides are installed on the fireplace for the front being used.
  • Page 26 1”. This is the depth of the finishing guides on the fireplace and will result in the best final appearance. Mendota does not guarantee any materials used around the fireplace. Mendota disclaims any and all liability for any damage to finishing materials including warping, discoloring, cracking, peeling or flaking.
  • Page 27 Ceramic or Porcelain Tile Use of ceramic or porcelain tiles as facing materials around a Mendota fireplace is approved. If selecting a mosaic tile where tiles are held together with a webbing, ensure the webbing is a non-combustible material like fiberglass. Also ensure that the tiles are not attached to the webbing with a glue or epoxy that will off gas and smell when heated.
  • Page 28: Paint Types Approved For Use

    Mendota fireplaces. Mendota further cautions that proper adhesives be used to attach stone facings. Pay attention to the potential of off gassing of chemical vapors from mastic and other adhesives.
  • Page 29: Framing Depth And Finishing Guides

    Please read the following instructions before installing the finishing material on the front of this fireplace. If you have any questions about finishing the fireplace, contact a Mendota dealer or the Mendota Service Department. • To prevent damage, remove any decorative front, screen, or door from the fireplace and mask the fireplace...
  • Page 30 Recessed Mount Guide Kit: Installing Front Flush or Recessed Into Wall Note: Order the Recessed Mount Guide Kit from the pricing sheet. This option allows the front to mount with any finish material. The front will fit inside the guides. Allowing the front to be recessed into the wall.
  • Page 31 Many television manufacturers specify in their installation instructions that the television must not be installed near or above a heat source. The decision to install a television near or above a Mendota fireplace rests solely on the consumer. It is the consumers responsibility to satisfy television specifications and ensure the television will not exceed maximum operation temperatures.
  • Page 32 Recommendation 3: Install a heat transfer system Mendota Hearth offers three heat transfer systems that take heat from the fireplace and redirect it to another area. When used correctly these heat transfer systems can make it possible to mount a television above the fireplace without installing a mantel or creating a recessed cavity.
  • Page 33: Mendota Cool Wall

    3.2.17.3.1 Mendota Cool Wall The Mendota Cool Wall system uses natural convection to take heat off the wall directly above the fireplace and redirects it up and away from surrounding areas. Testing has shown that when using a Cool Wall system, temperatures above the fireplace are reduced making it possible to mount a television 15”...
  • Page 34: Versiheat

    3.2.17.3.2 Versiheat The Versiheat system uses a fan to redirect heat from the fireplace to an alternate room in the home. WARNING: To reduce temperatures above the fireplace for mounting a television the Versiheat system must always be on when the fireplace is in operation.
  • Page 35: Flexheat

    3.2.17.3.3 FlexHeat The FlexHeat system uses two inline fans to redirect heat from the fireplace outside the home or to an alternate room in the home. WARNING: To reduce temperatures above the fireplace for mounting a television the FlexHeat system must always be on when the fireplace is in operation.
  • Page 36 Installation by unauthorized personnel; installation of any damaged component; unauthorized modification of vent system; installation of any components not approved by Mendota; failure to meet all clearance requirements; failure to properly twist-lock and positively seal all components. Consult local building codes before beginning the installation.
  • Page 37 Flue Venting Components Identification Diagrams Prior to installing at altitudes higher than 7500, please contact the Mendota technical service department for specific venting requirements and venting restrictions. ITEM DESCRIPTION 6" or 7” PIPE (DuraVent 6”/Amerivent 7”), 9”, 12” 12" VENT STACK 24"...
  • Page 38 Approved Vent Systems HORIZONTAL RUN STRAIGHT UP, WITH 90 DEG VERTICAL VENTING ELBOW. VERTICAL RISE HORIZONTAL TERMINATION MINIMUM 12" VERTICAL 24” MIN VERTICAL 50 FEET MAXIMUM NOT APPROVED APPROVED APPROVED VERTICAL RISE DUAL 90° ELBOWS HORIZONTAL TERMINATION VERTICAL RISE DUAL 90° ELBOWS VERTICAL TERMINATION 24”...
  • Page 39 Exterior Vent Locations and Restrictions Note: All measurements are to be taken from the center of the vent cap. ∨ - ∧ - ≡ - Vent Terminal Air Supply Inlet Area where terminal is not permitted Clearance above grade, veranda, porch, *Not to be installed above a meter/regulator deck, or balcony (*12 inches (30 cm) assembly within 3 feet (90 cm) horizontally from the...
  • Page 40 Side by Side installation of two Vent Caps When two or more vertical vent caps are located within proximity of one another, it is required that a galvanized steel 18-gauge or heavier barrier wall be installed between the two vent caps to eliminate recirculation of exhaust gases from one cap to another.
  • Page 41: Electrical Technical References

    3.3 ELECTRICAL TECHNICAL REFERENCES AC Power Requirements WARNING: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. For normal operation, this appliance requires 120 VAC, 2 Amp power or a 6V DC power source. The AC power supply to this Fireplace must be hot at all times and shall not have a switch installed in it.
  • Page 42 AC Power Connection STEP 1 STEP 2 STEP 3 Figure 3-13 Wire Connections Page 42 85-03-01307 FV46 FireIn...
  • Page 43: Backup Dc Power Inlet Port Installation

    Backup DC Power Inlet Port Installation INSTALLATION: It is important that you install the supplied harness, outlet box and cover plate on the left side of this appliance. The DC Power Inlet harness is 6 feet long, allowing installation of the single gang box up to 5 feet to the left of this appliance. Install the single gang box at a maximum height of 18”...
  • Page 44 PF2 Ignition System Diagram Note: Connect wires in junction box located on the left This appliance must be electrically connected and side of this appliance to house power using supplied wire grounded in accordance with local codes or, in the absence nuts.
  • Page 45: Plumbing Technical References

    ADHERE STRICTLY TO LOCAL AND NATIONAL CODES. Gas Supply Line Sizing This Mendota Gas Fireplace comes equipped with a 1/2" N.P.T. Female inlet. Gas supply piping must enter the Fireplace cabinet on the left side. Use the table, below, to determine the proper gas line diameter that must be installed to run from the supply regulator to the factory installed manual shutoff valve.
  • Page 46 Gas Pressure Requirements and Checking Two pressure taps for checking input and output gas pressures are located on the main gas valve. A qualified installer should use this fitting for setting the correct gas pressure during initial installation. The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2...
  • Page 47 Factory Installed Manual Gas Shutoff Valve A manual gas shutoff valve is factory installed and located in the left-side convection chamber. To operate the manual gas shutoff valve, insert the tip of the glass latch tool into the hole in the valve activation bracket (shaped like an arrow head). Rotate the tool downward 90-Degrees or until it stops to fully close the Valve.
  • Page 48: Gas Input Rate Verification

    Gas Input Rate Verification Natural Gas Input Rate Verification 1. Verify main orifice size. The main orifice body has the orifice hole size stamped on it. NG orifice size shall be #47(pan burner), #52 (left burner) and #44 (right burner) for all elevations between 0-2000ft. NG orifice size shall be #47 (pan burner), #521 (left burner) and #44 (right burner) for all elevations exceeding 2000ft.
  • Page 49: Installation Checklist

     Sealant is not required at vent joints. Do not use silicone sealants in vent connection joints anywhere.  Adjust exhaust damper to match vertical chimney length. See 4.11.15 Vent Damper Adjustments  Co-axial vent rigid pipe, wall vent cap or roof vent cap is installed by a Mendota approved serviceperson in accordance with instructions.
  • Page 50: Unpacking The Fireplace

    Lift the outer box vertically straight upward until lower edge of the box clears the top of the unit body. Set the box aside. Mendota recommends recycling the outer box. Figure 4-1 Outer Box Removal Page 50...
  • Page 51: Contents Of The Manualp

    Once the outer box is removed, you will find the Fireplace body and a manual packet white box. This manual packet white box includes the items shown in the table, below. Contact Mendota Technical Service if any parts are missing.
  • Page 52: Bending Up The Shipping Clips

    4.6 BENDING UP THE SHIPPING CLIPS Once the unit is detached from the pallet by removing the securing lag screws that hold these shipping clips to the pallet, either bend these clips up 90-degrees or break them off using a screw driver and back and forth cold working motion (see below). A bending relief is provided within the clip to ease bending or breaking.
  • Page 53: T Oremove Door

    4.7 TO REMOVE DOOR Use the glass latch tool to disconnect the spring latches from the glass frame. Insert tool into hole in latch, pull towards you and rotate 180- degrees to disengage top latches. Remove tool. There are two spring latches on top of this gas fireplace.
  • Page 54 Figure 4-7 Light Housing Caution: Do not touch the light lens with bare hands. Always use the protective foam wrap supplied with the light bulb or a pair of clean cloth or neoprene gloves to handle the light bulb. Touching the light bulb will leave oils and dirt on the lens and will cause premature failure of the light bulb.
  • Page 55: Natural Gas To Lpg Conversion

    General Conversion Information Kit # HA-150-00011 for Mendota Model FV46 FireIn This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction.
  • Page 56: Pressure Regulator Conversion

    Pressure Regulator Conversion WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. 1. See Figure 1: Using a Torx T20 (supplied) or slotted screwdriver, remove and discard the two pressure-regulator mounting screws (A);...
  • Page 57 1. Remove the left and right angled burners by removing 4 screws each. Remove the floor by removing 2 screws from the rear. NOTE: LEFT AND RIGHT BURNERS ARE LABELED WITH AND “L” AND “R” 2. Install #59 orifice to Left angled burner.
  • Page 58 Burner Ignition Characteristics Note: Connect gas supply and verify that the minimum inlet and outlet pressures are conforming. Once the conversion to LPG and all the above steps have been completed, install log set and glass door then light the main burners.
  • Page 59: Venting

    CAUTION: Each installation must conform to all local, state and national codes. Refer to the national fuel gas code and local zoning and code authorities for details on installation requirements. The Mendota Fireplaces must be vented to the outside in accordance with the latest edition of the National Fuel Gas Code.
  • Page 60: High Altitude Installation Information

    FV46 Master Venting Chart If using a Mendota approved power vent kit, consult the power vent instruction manual for additional venting configurations. 1. 24” minimum vertical pipe required to be connected directly to this fireplace’s flue starter collar. 2. 18” maximum horizontal run allowed with the minimum 24” vertical rise.
  • Page 61: Maximum Horizontal Run

    Maximum Horizontal Run Maximum Horizontal Run allowed is 20 feet if a vertical starter section of 4 feet to 30 feet is connected directly to the • fireplace’s flue starter collar. • 18” maximum horizontal run allowed with the minimum 24” vertical rise. SUPPORT: Horizontal runs of pipe will require one vent support for every 3 ft.
  • Page 62 MINIMUM RISE HORIZONTAL TERMINATION The FV46 Fireplace must be installed by a qualified Mendota approved serviceperson. 18” maximum horizontal run allowed with the minimum 24” vertical rise. With the minimum 24” vertical pipe and a 90-degree elbow connected to the fireplace, the horizontal centerline of the 90ºelbow will be 69 ½”...
  • Page 63: Vertical Rise Horizontal Termination

    NOTE: The horizontal run of vent pipe must have a ¼" rise for every 1' of run toward the termination. Never allow the vent to run downward. This will cause high temperatures and the possibility of a fire. This FV46 FireIn Fireplace must be installed by a qualified Mendota service person Position fireplace in desired location.
  • Page 64 V min H1 + H2 max 36 in. 7’-9” 4 ft. - 30 ft. 31ft. - 50 ft. 47 - V V1 min V1 + V2 max H1 + H2 max 36 in. 50’ 4’-9” 4 ft. - 30 ft. 50’...
  • Page 65: Vertical Through-The Roof Venting

    Wall straps are available for this purpose. The FV46 Fireplace must be installed by a qualified Mendota approved serviceperson. Place the fireplace in its desired location. Drop a plum bob from the ceiling to the position of the fireplace flue exit. Mark the location where the vent will penetrate the ceiling.
  • Page 66 V1 min V2 max H max 2 ft. 48’ - H 17’ 4 ft. 46’ - H 17’ 4 ft. - 30 ft. 50’ – H – V1 31ft. - 50 ft. 50’ – H – V1 47’ – (V1) Page 66 85-03-01307 FV46 FireIn...
  • Page 67: Vertical Through-The-Roof Venting Using Four

    VERTICAL THROUGH-THE-ROOF VENTING USING FOUR 90 ELBOWS The use of Four 90 elbows must meet some minimum prerequisites. Prerequisite #1: The vent system must terminate vertically using a vertical vent cap. Prerequisite #2: There must be a minimum of 24 inches of vertical starter section connected directly to the top of this fireplace. Prerequisite #3: For vertical starter sections less than 4 feet tall, you must reduce 9 feet off the maximum horizontal run allowed per the Master Venting Chart.
  • Page 68: Vent Damper Adjustments

    Vent Damper Adjustments This fireplace is equipped with a vent damper system that can be adjusted using the glass latch tool. The damper can be adjusted to improve the flame appearance. Locate the damper adjustment rod at the center of the convection chamber above the glass frame.
  • Page 69: Approved Vent Systems

    • The fireplace may be vented using a Mendota approved power vent. • The total vent length must be between 1’ to 80’ and can use up to 6 90° elbows or combination of other elbows equaling 90°.
  • Page 70 Power Vent Exterior Vent Locations and Restrictions Note: All measurements are to be taken from the edge of the Power Vent. Page 70 85-03-01307 FV46 FireIn...
  • Page 71: Log Set/ Media Installation

    4.13 LOG SET/ MEDIA INSTALLATION Four distinctive wood species log sets are available as options for this model Fireplace. 1. AA-11-05481 BIRCH HD LOG SET 2. AA-11-05482 WHITE OAK HD LOG SET Installation Instructions for each log set are included with the individual log set. Follow those instructions to install one log set. Note: Installer, save and give the copy of the Log Set Installation Instructions to the homeowner for future references.
  • Page 72: Tube Air Shutter Control And Flame Appearance

    4.15 TUBE AIR SHUTTER CONTROL AND FLAME APPEARANCE During the initial installation, the air shutter opening should be checked and set as described below. Nat Gas - Burner Tubes: 1/8” – 1/4” Pan Burner: 3/8” – 1/2” LP Gas - Burner Tubes: 3/8” – 1/2” Pan Burner: 3/8" – 1/2" NOTE: For altitudes above 5,000 Ft., some variations may be required.
  • Page 73: Aesthetic Considerations

    We are committed to quality and satisfaction for all Mendota owners. Thank you for choosing a Mendota to be a source of comfort and beauty in your home.
  • Page 74: Using Your Remote Control

    Using Your Remote Control Your Mendota remote control is pre-programmed to your fireplace. Ensure you have installed 3 AAA batteries into your remote. Press the top button on the remote control. If you do not hear a beep when you press this button, follow the instructions below to synchronize your fireplace and remote control.
  • Page 75: Remote Control Functions

    Remote Control Functions NOTE: You will hear an audible beep once every time a remote-control button is pressed, signaling that the command has been received. If you do not hear the beep, press the button again. Locate the four function buttons on the remote control: 1.
  • Page 76: Instructions

    5.5 REMOTE CONTROL OPERATING INSTRUCTIONS To Turn on the Fireplace NOTE: If the fireplace does not respond to the remote-control commands but it responds by beeping only, the fireplace system may have entered “safety lockout” mode. To reset the system, see Chapter 5.11.13 Why won’t my fireplace turn on?.
  • Page 77 Icon Details Mode Button: Pressing the mode button toggles between the various available functions: flame height, fan speed, accent light intensity and rear burner on/off. Flame Height: Six flame height levels are available. While the flame height icon is displayed, pressing the up or down button once will increase or decrease the flame height by one of six increments.
  • Page 78: Odes

    Note: The snowflake icon will be visible on the display at all times when in CPI mode. Recommended: Mendota recommends that CPI mode is used during the winter months when the average daily high temperature falls below 50 °...
  • Page 79: First Time Lighting Instructions

    5.8 FIRST TIME LIGHTING INSTRUCTIONS • WHAT TO DO IF YOU SMELL GAS Warning: If you do not • Do not light any appliance. follow these instructions • Do not touch any light switch. exactly, a fire or explosion • Do not use any phone in your building.
  • Page 80: Frequently Asked Questions

    Where can I find the model and serial numbers? When requesting service, you will be asked to provide the model number and serial number to your Mendota dealer. This information will expedite the warranty verification process. The Listing Label contains the model number and serial number for your particular appliance.
  • Page 81 Can I use my Fireplace during power outages? This electronic ignition system uses the supplied 110VAC power when it is available for all functions of this system. If you experience a power outage, plug in the battery pack (6V DC maximum, supplied with this fireplace) to the fireplace backup power inlet port.
  • Page 82 These adjustments should be made by a qualified technician to achieve the best flame performance. Contact your installer or Mendota dealer if you feel your fireplace is not burning correctly. Improper setup and adjustment is not covered under warranty.
  • Page 83: What Happens When I First Light My Fireplace

    This should clear the lockout mode. Turn on the remote and start the fireplace. Ensure the master switch is in the run/on position. After completing these steps, contact your Mendota dealer if fireplace won’t turn on. What happens when I first light my fireplace? When you first light your fireplace, the initial curing phase is initiated.
  • Page 84: Maintenance Information

    MAINTENANCE INFORMATION 6.1 REQUIRED PERIODIC INSPECTIONS 1. Check to verify that the vent system and vent cap are open and free of blockage. 2. Have qualified service person check the operation of the pilot light. Pilot light must light within the first five to eight seconds of ignitor sparks initiation.
  • Page 85: Ignition System Lockout Mode And 6.6 Burner Flame Heightsr

    If you are using a “backyard” Natural Gas well as the gas source, you must submit formal gas analysis data sheets to Mendota Fireplaces for review and calculation of proper main burner orifice sizes prior to first firing. It is known that unpurified Natural Gas from “backyard” wells can contain high energy levels causing over firing.
  • Page 86: Replacement Parts Information

    Accent Light: The accent light is mounted in the firebox top center area. The accent light wire harness is run from the light housing to the left side and then down to the ignition control module. Please contact your Mendota Dealer for parts availability and parts pricing. Page 86...
  • Page 87: Valve Assembly Parts List

    Valve Assembly Parts List Please contact your Mendota Dealer for parts availability and parts pricing. ITEM PART NUMBER DESCRIPTION 05-04-00075 PILOT, PSE-NA361, 2-WAY HOOD 10-03-00105 GROUNDING WIRE EXTENSION, 19" HIGH TEMP 50-01-00156 HHSMS, #8-18 X 1/2" TYPE AB, BLACK ZINC 50-01-00174 SCREW, HEX WASHER, 8-32 X 3/8", TYPE F, BLK ZINC...
  • Page 88 Convection Air Blower System Parts Figure 6-3 FV46 BLOWER ASSY, LEFT Figure 6-4 FV46 BLOWER ASSY, RIGHT ITEM PART NO. DESCRIPTION 50-06-00130 SPACER, FOR GROMMET 50-06-00129 GROMMET, RUBBER 50-03-00067 NUT, 10-24 KEPS, ZINC PLATED 50-01-00156 HHSMS, #8-18 X 1/2" TYPE AB, BLACK ZINC 15-02-00121 BLOWER, LH 15-02-00120...
  • Page 89: To Replace Damaged Glass

    Glass Frame Parts Replacement Procedure WARNING: do not use substitute materials. All replacement materials must be certified and obtained through Mendota fireplaces. TO REPLACE DAMAGED GLASS 1. Bend glass retainer tabs up 90 degrees. Four tabs hold down the glass and gasket assembly.
  • Page 90: Final Installation And Homeowner Checklist

     Burner flames are “stable” and are not “lifting” off burner.  Inform owner that an initial curing step is required. Read and follow Mendota Fireplace and Insert Curing Instructions (found on unit and in owner’s manual). Smoke will emit during initial curing step.
  • Page 91: Warranty Policy Statement

    7.2 WARRANTY POLICY STATEMENT Mendota Fireplace, a division of Johnson Gas Appliance Company, extends this limited lifetime warranty to the original purchaser of this appliance provided the product remains in the original place of installation. The items covered by this limited warranty and the period of such coverage is set forth in the table below.
  • Page 92: Onditions

    Owner accepts that this appliance requires close monitoring of children and vulnerable individuals who are in the vicinity of this appliance when it is in operation. Mendota does not assume or accept any liability claims for burns or other physical or material damages resulting from touching hot glass surface and hot metal surfaces that are part of this appliance or other adjacent object such as hearth pads and mantels that may heat up during operation of this appliance.
  • Page 93: Limitations Of Liability

    How to Obtain Warranty Service 16. If you discover a problem that you believe to be covered by the warranty, you must report it to your Mendota Dealer within 30 days, with proof of purchase, purchase date, model name and serial number.
  • Page 94 Owner Registration After installation, Mendota fireplace owners must register with Mendota to qualify for the lifetime warranty within 30 days. Product registration will activate your limited warranty. Owners should complete the forms available at: mendotahearth.com/warranty Note: Your Mendota dealer can assist with warranty applications and information.
  • Page 96 Johnson Gas Appliance Company 1155 Sherman Rd. Hiawatha, IA 52233 Mendota Warranty Registration...

This manual is also suitable for:

Firein fv46

Table of Contents